期刊文献+

预制夹芯保温墙体FRP连接件的力学性能试验 被引量:38

Mechanical properties test of FRP connectors in precast sandwich insulation wall panels
在线阅读 下载PDF
导出
摘要 针对预制夹芯保温墙体中FRP连接件的受力性能直接影响到墙体安全性的问题,以上海市某安居工程为背景,通过FRP连接件的拔出试验和抗剪试验,对FRP连接件的抗拔承载力、抗剪承载力、破坏形态、荷载-滑移关系与荷载-应变关系进行了研究.结果表明:FRP连接件的抗拔承载力为23.5 kN,平面内和平面外两种不同布置方案的抗剪承载力分别为19.6 kN和12.6 kN,满足工程设计要求,并具有较大的安全储备.并对预制夹芯保温墙体的热工性能进行了研究,结果表明:采用FRP连接件的预制夹芯保温墙体的传热系数K=0.407 W·(m2·K)-1,满足国家建筑节能标准要求. To solve the problem that the safety of precast sandwich insulation wall was influenced by the mechanical behavior of FRP connector,the model from a practical project in Shanghai was used as reference.The tests of three pull-out specimens and six shear specimens were used to investigate the properties of FRP connectors of pull-out capacity,shear bearing capacity,failure pattern and load-slip curve.The results show that the pull-out capacity of the connector is 23.5 kN.When the connectors are arranged parallel and vertically to the shear load,the shear bearing capacities of the connector are 19.6 kN and 12.6 kN,respectively.The connectors can meet the design requirement in practical project with a great safety margin.The thermal performance of precast sandwich insulation wall was also tested.The results show that heat transfer coefficient of the wall is 0.407 W · (m^2 · K)^-1,and can meet the need of building energy-saving standard.
出处 《江苏大学学报(自然科学版)》 EI CAS CSCD 北大核心 2013年第6期723-729,共7页 Journal of Jiangsu University:Natural Science Edition
基金 教育部新世纪优秀人才支持计划项目(NCET-10-0636) 上海市科委重点项目(10dz0583700 10dz0583600)
关键词 FRP连接件 预制夹芯保温墙体 抗拔承载力 抗剪承载力 热工试验 FRP connector precast sandwich insulation wall panel pull-out bearing capacity shear bearing capacity thermodynamic test
  • 相关文献

参考文献3

二级参考文献17

  • 1张新越,欧进萍.FRP筋酸碱盐介质腐蚀与冻融耐久性试验研究[J].武汉理工大学学报,2007,29(1):33-36. 被引量:66
  • 2[3]Semih,Soner,Selin.Energy ef ficiency assessment for the antalya region hotels in Turkey[J].Energy and Buildings,2006,38(8):964~971.
  • 3[4]Tiwari,Piyush.Energy efficiency and building construction in India[J].Building and Environment,2001,36(10):1127~1135.
  • 4BANK L C, GENTRY. Accelerated test methods to determine the long-term behavior of FRP composite structures: environmental effects [ J ]. Journal of Reinforced Plastic and Composites, 1995, 14 (6) : 558- 587.
  • 5ACI 440. 3R-04 Guide test methods for fiber reinforcedpolymers (FRPs) for reinforcing or strengthening concrete structures[ S]. American Concrete Institute, 2004.
  • 6VALTER DEJKE. Durability of FRP reinforcement in concrete :literature review and experiments [ D ]. Goteborg: Chalmers University of Technology, 2001.
  • 7PORTER M L, BARNES B A. Accelerated aging degradation of glass fiber composites [ C ]//Fiber Composites in Infrastructure: Proceeding of the Second International Conference on Fiber Composites in Infrastructure, Tucson, 1998 : 446-459.
  • 8MUKHERIEE A, ARWIKAR S J. Performance of glass fiber-reinforced polymer reinforcing bars on tropical environments-part II: Micro structural tests [ J ]. ACI Structure Journal, 2005, 102 (6) : 16-22.
  • 9BANK L C, GENTRY. Accelerated aging of puhruded glass/vinyl ester rods [ C ]//Fiber Composites in Infrastructure: Proceedings of the Second International Conference on Fiber Composites in Infrastructure, Tucson, 1998 : 423-437.
  • 10Huang Wei, Jing Gang, Yao Qianfeng. Study on a new energy-saving composite wall[J]. Journal of Harbin In- stitute of Technology, 2007,14 ( S ) :442 - 446.

共引文献171

同被引文献160

引证文献38

二级引证文献152

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部