摘要 The lean blowout experiments of the combustion stability device A (multi-vortexes-dome model combustor) have been carried out at atmospheric pressure. Compared with the device B (single-vortex-dome model combustor), the experimental results show that the device A has a superior lean blowout performance when the combustor reference velocity is within the range from 3.50m/s to 5.59m/s ( while the liner reference velocity is between 3.84 and 6.13m/s), and this superiority will remain stable after the inlet air flow rate reaches a certain value. In order to analyze the phenomena and experimental results, the numerical simulation method is used, and the strain rate and the cold reflux impact are employed to further explain the reason that causes the difference between the two devices' lean blowout characteristics.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2013年第4期366-371,共6页 热科学学报(英文版)
基金 supported by the National Natural Science Foundation of China (No. 50876104) the Major State Basic Research Development Scheme of China (No. 2012CB720406)
关键词 lean blowout primary zone DOME multi-vortexes COMBUSTOR 球型燃烧室 井喷 实验装置 燃烧稳定性 贫油熄火 大气压力 数值模拟