摘要 以AP1000核电依托化项目中核电站钢制安全壳补强板与贯穿件套筒管板焊缝超声检测技术难点分析为切入点,重点描述了焊缝模拟件的选择原则及制作、超声检测工艺参数的选择,并分析了此类管板焊缝超声检测时容易出现的焊接缺陷和原因。 Through analyzing the technical difficulties of ultrasonic testing containment vessel(CV) stiffener plate and penetrate sleeve plate in AP1000 nuclear power self-reliant project as a pointcut,this thesis focuses on the principle to fabricating a demo and choosing process parameters of UT,and analyses the welding defects likely to occur during UT for such pipe plate and reason analysis.
出处 《压力容器》 2013年第1期75-79,共5页 Pressure Vessel Technology
关键词 管板焊缝 模拟件 超声检测 tubular plate welds demo ultrasonic testing
  • 相关文献

参考文献12

二级参考文献24

共引文献43

同被引文献18

  • 1李衍.超声相控阵技术 第一部分 基本概念[J].无损探伤,2007,31(4):24-28. 被引量:69
  • 2SHAO Jiaxin, DU Dong, CHANG Baohua. Automatic weld defect detection based on potential defect track- ing in real -time radiographic image sequence [ J ]. NDT&E International,2012,46 : 14 - 21.
  • 3CHERTOV A M, KARLOFF A C, PEREZ W, et al. In - process ultrasound NDE of resistance spot welds [ J ]. Insight - Non - Destructive Testing and Condition Monitoring,2012,54 (5) :257 - 261.
  • 4GROSLIER D, PELLERIN S, VALENSI F. Explorative approach of the spectral analysis tools to the detection of welding defects in lap welding [ J ]. Nondestructive Testing and Evaluation,2011,26 ( 3 ) : 13 - 18.
  • 5DU Dong, CAI Guorui, TIAN Yuan, et al. Automatic in- spection of weld defects with X - Ray real - time ima- ging[ J]. Lecture Notes in Control and Information Sci- ences,2007,362 : 359 - 366.
  • 6ASME Boiler & pressure Vessel Code, Section V: Nondestructive Testing[ S].
  • 7Dr. Michael D. C Moles, Introduction to Phased Array Ultrasonic Technology Application [ M ]. R/D Tech Inc. 2004.
  • 8Zappavigna G. Application of phased array in inspec- tion of nozzle welds of high thickness reactors manu- factured by GE oil & gas massa plant[ J]. Insight, Non -destructive Testing and Condition Monitoring,2007, 49(9) :521 -523.
  • 9ASME Code Case 2235 - 9 [ S ]. Use of Ultrasonic Ex- amination in lieu of Radiography.
  • 10ASTM E2007 -09 [ S ]. Standard Practice for Contact Ultrasonic Testing of Weld Using Phased Array.