摘要 腰椎融合术是治疗腰椎退行性疾病的标准术式,但腰椎融合率与临床症状改善率之间不成止比,随着时间的推移,融合的相邻节段会发生退变或失稳,导致相邻节段退变.腰椎融合手术所存在的局限性及问题导致一些学者开始探索一些新的手术方式,腰椎非融合技术是近年来发展起来的腰椎退变疾病的新治疗手段, In recent years, the lumbar non-fusion technique remains a hot research topic in spine surgery, and the Dynesys dynamic stabilization system is one of the most widely applied non-fusion techniques clinically. The system is designed to stabilize the operated segments and meanwhile preserve some mobility, so as to prevent the stress concentration of adjacent segments and relieve adjacent segment degeneration. Many clinical studies show that the Dynesys system could have satisfied clinical results, but at present there are still some controversies about the role of the Dynesys dynamic stabilization system in reducing adjacent segment degeneration. The biomechanical and clinical research about the role of the Dynesys system in preventing adjacent segment degeneration is reviewed in this article, to provide clinical evidence.
作者 张阳 李放
出处 《中国骨与关节杂志》 CAS 2013年第6期358-360,共3页 Chinese Journal of Bone and Joint
关键词 腰椎退行性疾病 腰椎退变 相邻节段 动态固定 系统 腰椎融合术 非融合技术 标准术式 Intervertebral disc degeneration Lumbar vertebrae Spinal diseases Dynesys syetem
  • 相关文献

参考文献27

  • 1Anandjiwala J,Seo JY,Ha KY. Adjacent segment degeneration after instrumented osterolateral lumbar fusion:a prospective cohort study with a minimum five-year follow-up[J].{H}European Spine Journal,2011,(11):1951-1960.
  • 2Chen BL,Wei FX,Ueyama K. Adjacent segment degeneration after single-segment PLIF:the risk factor for degeneration and its impact on clinical outcomes[J].{H}European Spine Journal,2011,(11):1946-1950.
  • 3Babu MA,Coumans JV,Carter BS. A review of lumbar spinal instrumentation:evidence and controversy[J].{H}JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY,2011,(09):948-951.
  • 4Lee MJ,Lindsey JD,Bransford RJ. Pedicle screw-based posterior dynamic stabilization in the lumbar spine[J].{H}Journal of the American Academy of Orthopaedic Surgeons,2010,(10):581-588.
  • 5Berman DS. A current review of outcome studies on the Dynesys system for dynamic stabilization of the lumbar spine[J].Int J Orthop Surg,2011,(02):1-7.
  • 6Kim CH,Chung CK,Jahng TA. Comparisons of outcomes after single or multilevel dynamic stabilization:effects on adjacent segment[J].{H}Journal of Spinal Disorders and Techniques,2011,(01):60-67.
  • 7Bothmann M,Kast E,Boldt GJ. Dynesys fixation for lumbar spine degeneration[J].{H}NEUROSURGICAL REVIEW,2008,(02):189-196.
  • 8李放,张志成,任大江.Dynesys动态稳定系统在腰椎退变性疾病治疗中的应用[J].脊柱外科杂志,2012,10(5):288-292. 被引量:20
  • 9Gédet P,Haschtmann D,Thistlethwaite PA. Comparative biomechanical investigation of a modular dynamic lumbar stabilization system and the Dynesys system[J].{H}European Spine Journal,2009,(10):1504-1511.
  • 10Schulte TL,Hurschler C,Haversath M. The effect of dynamic,semi-rigid implants on the range of motion of lumbar motion segments after decompression[J].{H}European Spine Journal,2008,(08):1057-1065.

二级参考文献25

  • 1Huskisson EC. Measurement of pain [ J] . Lancet, 1974, 2 (7889) : 1127-1131.
  • 2Fairbank JC, Couper J, Davies JB, et al. The Oswestry low back pain disability questionnaire[ J]. Physiotherapy, 1980, 66 (8) : 271-273.
  • 3Bothmann M, Kast E, Boldt GJ, et al. Dynesys fixation for lum- bar spine degeneration [ J ]. Neurosurg Rev, 2008, 31 ( 2 ) : 189-196.
  • 4Trommsdorff U, Zurbrtigg D, Abt NA, et al. Analysis of retrieved components of a dynamic stabilization system for the spine [ R ]. Vienna :Austria, Spine Arthroplasty Society, 2004.
  • 5Trommsdoff U, Zurbrtigg D, StoU TM. In-vivo degradation of polycarb0nate-urethane with and without contact to an abscess [R]. Sydney: Australia, 7thWorld Biomaterials Congress, 2004.
  • 6Trommsdorff U, Kottig P. Analysis of retrievals of the Dynesys dynamic stabilization system for the spine [ R ]. Barcelona: Spain, Earospine, 2005.
  • 7Meyers K, Tauber M, Sudin Y, et al. Use of instrumented pedi- cle screws to evaluate load sharing in posterior dynamic stabiliza- tion systems[J]. Spine J, 2008, 8(6) :926-932.
  • 8Nohara I-I, Kanaya F. Biomechanical study of adjacent interverte- bral motion after lumbar spinal fusion and flexible stabilization using polyethylene-terephthalate bands [ J ]. J Spinal Disord Tech, 2004, 17(3) :215-219.
  • 9Schuhe TL, Hurschler C, Haversath M, et al. The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression[ J]. Eur Spine J, 2008, 17 ( 8 ) : 1057-1065.
  • 10Niosi CA, Zhu QA, Wilson DC, et al. Biomechanical character- ization of the three-dimensional kinematic behaviour of the Dyne- sys dynamic stabilization system: an in vitro study[ J]. Eur SpineJ, 2006, 15(6) :913-922.

共引文献19

同被引文献44

  • 1郭立新,陈威,刘学勇.基于有限元模型的人体损伤脊柱的动态特性分析[J].东北大学学报(自然科学版),2005,26(9):836-839. 被引量:17
  • 2杨惠林,唐天驷.腰椎不稳与腰椎管狭窄专题研讨会纪要[J].中华骨科杂志,1994,914(1):60-63.
  • 3Kumar A,Beastall J,Hughes J,et aI.Disc changes in the bridged and adjacent segment after Dynesys dynamic stabilization system after two years.Spine (Phila Pa 1976). 2006;33(26):2909-2914.
  • 4De lure F, Carson WL,Hardacker JW, et aI.The effect of arthrodesis,implant stiffness,and time on the canine lumbar spine. JSpine Disord Tech.2007;20:549-559.
  • 5Jensen MP, Karoly P, Braver S. The measurement of clinical painintensity: a comparison of six methods. Pain. 1986;27(1 ); 117-126.
  • 6Falrbank JC, Pynsent PB. The Oswestry Disability Index. Spine (Pbi!a Pa 1976). 2000;25(22): 2940-2952.
  • 7Ghlsell C,Wang JC,Bhatia NN,et al.Adjacent segment degeneration n the lumbar spine.J Bone Joint Surg Am. 2004;86(7); 1497-1503,.
  • 8Stol TM,Dubo s G,-chwitrzenbach O.The dynamic neutralization sy@tem for the sp ne a multi-center study of a novel non-fusion system.Eur Spine J, 2002;11 Suppl 2:S 170-178,.
  • 9陈兵乾,张烽.腰椎椎间融合术的研究进展[J].脊柱外科杂志,2007,5(5):308-309. 被引量:12
  • 10Sears WR, Sergides IG, Kazemi N, et al. Incidence and preva- lence of surgery at segments adjacent to a previous posterior lumar arthrodesis [ J ]. Spine, 11 ( 1 ) : 11 - 20.

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部