期刊文献+

75%乙醇与丙酮卸下小儿长程脑电图电极的临床比较 被引量:3

CLINICAL COMPARISON OF 75% ETHANOL AND ACETONE IN REMOVE OF ELECTRODES ON LONG-TERM EEG OF CHILDREN
在线阅读 下载PDF
导出
摘要 目的:比较使用75%乙醇及丙酮两种取电极方法的效果,探讨更佳长程脑电监测技术。方法:将125例长程脑电图检查患儿随机分为实验组(75%乙醇),对照组(丙酮)。通过观察卸下电极所用时间、《聚氨酯产品气味评价表》和《Wong-Baker面部表情量表》等,比较使用不同溶剂取电极的临床效果。结果:实验组卸下电极的平均时间长于对照组,实验组对溶剂气味的耐受性高于对照组、疼痛指数低于对照组,两组比较均有差异,有统计学意义(P<0.05)。结论:75%乙醇能安全、有效卸下电极,较丙酮刺激性更小,具有可行性,值得推广。 Objective: To compare the effect of 75% ethanol and acetone in remove of electrodes and explore a better technology on long-term EEG monitoring. Methods: 125 children accepted long-term EEG were randomly divided into two groups, the experimental group ( 75% ethanol ) and the control group ( acetone ). Two groups were compared in the time of remove of electrodes, 《 Odor evaluation form of polyurethane products》 and 《 Wong-Baker facial expression scale》 , etc. so that observe clinical effect of using different solvents. Results: The average time of remove of electrodes of experimental group is longer than that of the control group, the tolerance of solvent odor of the experimental group is also higher than that of the control group, but it's pain indexs is lower than that of the control group. There was difference in statistical significance in two groops ( P 〈 0.05 ) . Conclusion: 75% ethanol can remove the electrode safely and effectively and minor irritation than acetone, it is feasible, and worthy of promotion.
出处 《现代电生理学杂志》 2012年第2期76-79,92,共5页 Journal of Modern Electrophysiology
关键词 儿童 长程脑电图 75%乙醇 丙酮 children long-range EEG 75% ethanol acetone
  • 相关文献

参考文献7

二级参考文献6

共引文献126

同被引文献19

  • 1吴从容.急性丙酮中毒两例报告[J].中国工业医学杂志,1995,8(4):248-248. 被引量:7
  • 2遇涛,李勇杰,张国君,王玉平,卢德宏,陈莉,蔡立新,杜薇.MRI和CT阴性表现的脑致痫灶定位研究[J].中华神经外科杂志,2006,22(4):226-229. 被引量:22
  • 3大熊辉雄.临床脑电图学[M].5版.周锦华译.北京:清华大学出版社.2005:9-10.
  • 4Netherton BL, Stecker MM, Patterson T. Mechanisms of electrode induced injury. Part 3:practical concepts and a- voidance[J]. Am J Electroneurodiagnostic Technol, 2007, 47 (4) : 257-263.
  • 5Young B, Blais R, Campbell V, et al. Vapors from collodi on and acetone in an EEG laboratory[J]. J Clin Neuro- physiol, 1993,10(1) : 108-110.
  • 6Ma R,Kim DH,McCormick M,et al. A stretchable elec- trode array for non-invasive, skin-mounted measurement of electrocardiography ( ECG), electromyography (EMG) and electroencephalography (EEG) [J]. Conf Proc IEEE Eng Med Biol Soc,2010(2010):6405-6408.
  • 7Jarrar R, Buchhalter J, Williams K, et al. Technical tips: Electrode safety in pediatric prolonged EEG recordings [J]. Am J Electroneurodiagnostic Technol, 2011,51 (2) : 114-117.
  • 8Kolls BJ, Olson DM, Gallentine WB, et al. Electroenceph- alography leads placed by nontechnologists using a tem- plate system produce signals equal in quality to technolo- gist-applied,collodion disk leads[J]. J Clin Neurophysiol, 2012,29(1) :42-49.
  • 9Berlin F, Carlile JA, de Burgo MI, et al. Technical tips : E- lectrode application and preventing skin breakdown tech- niques[J]. Am J Electroneurodiagnostic Technol, 2011,51 (3) :206-219.
  • 10宁翠霞,王红.改良脑瘫患儿视频脑电监护安放电极的方法[J].临床误诊误治,2009,22(12):73-73. 被引量:3

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部