摘要
详细介绍了一种既适用于高炉闭路冷却系统 ,又适用于高炉开路冷却系统的进出水温度、水温差、流量、流速、热负荷及检漏在线监测技术 描述了该技术基于的基本原理和要求以及检测系统所采用的分步式计算机网络结构特点 最后 。
The on line measuring technology suitable for closed cooling system as well as open cooling sysem of blast furnace in the water temperature,the difference in water temperature,the rate of flow,the current velocity,the heat load and lead water detection is introduced.The fundamental principles and requirements involved and distributed computer network applied in the measuring system are described.The situations in industrial use are analyzed and summed up.
出处
《包头钢铁学院学报》
2000年第1期80-86,共7页
Journal of Baotou University of Iron and Steel Technology
基金
内蒙古自治区科技攻关项目! ( 960 2 1 2 )
关键词
高炉
冷却系统
热负荷
检漏
在线监测
blast furnace cooling system
heat load
leak water detection
on line monitoring and measuring