乳腺触觉成像诊断乳腺疾病临床价值研究 被引量:14

The value of palpation imaging in the diagnosis of breast diseases
原文传递
导出
摘要 目的探讨乳腺触觉成像(palpationimaging,PI)对乳腺疾病的诊断价值。方法对2010年10月至2011年3月在上海交通大学医学院附属瑞金医院乳腺外科就诊的151例病人共计213个病灶,行PI、B超、钼靶及磁共振成像(MRI)检查,各检查方法独立进行。以病理诊断为金标准,通过受试者工作特征曲线(ROC曲线)评估PI对乳房病灶的诊断价值,并比较不同方法诊断结果的差异。结果 PI对病灶的良恶性具有较好的诊断价值(AUC=0.832,95%CI:0.766~0.898,P<0.001),敏感度为87.0%,显著高于钼靶(63.5%,P=0.005),与B超(87.0%)及MRI(94.0%)相比差异无统计学意义。PI的特异度及准确率为69.8%与74.2%,与钼靶相比差异无统计学意义(80.5%,P=0.041,未达到调整后检验水准α’=0.0083;75.4%,P=0.778),但显著低于B超(86.2%,P<0.001;86.4%,P=0.002)及MR(I85.7%,P=0.005;88.7%,P<0.001)。结论 PI对于乳房疾病具有良好的诊断价值,有望成为乳腺疾病现有辅助检查外的又一种重要检查方法。 Objective To assess the value of palpation imaging(PI) in the diagnosis of breast diseases. Methods From October 2010 to March 2011, 151 patients with 213 breast lesions, of which 54 were breast cancers and 159 were benign lesions, were examined by PI, ultrasound, mammography and magnetic resonance imaging (MRI) in Comprehensive Breast Health Center, Ruijin Hospital, Shanghai Jiaotong University. Receiver operating characteristic (ROC) curve was drawn to determine the cutoff value of the PI test. The diagnostic value of the four examinations were compared. Results The AUC value of the ROC curve was 0.832(95%CI: 0.766 ~ 0.898, P〈0.001) in the diagnostic tests of PI. The sensitivity of PI was 87.0%, which is higher than that of mammograghy (63.5%, P=0.005) significantly and not statistically different compared with ultrasound (87.0%) or MRI(94.0%). The specificity and acuracy of PI (69.8%, 74.2%) was similar to that of mammography (80.5%, P=0.041, c~' =0.0083; 75.4%, P=0.778), but lower than that of ultrasound (86.2%, P〈0.001; 86.4% , P=0.002) and MRI (85.7% , P=0.005; 88.7%, P〈0.001) significantly. Conclusion PI is capable of differentiating benign and malignant breast lesions, and may become an important supplement of ultrasound, mammography and MRI in the diagnosis of breast diseases.
出处 《中国实用外科杂志》 CSCD 北大核心 2012年第5期390-394,共5页 Chinese Journal of Practical Surgery
关键词 乳腺肿瘤 触觉成像 B超 钼靶 磁共振成像 breast neoplasm palpation imaging ultrasound mammography magnetic resonance imaging
  • 相关文献

参考文献13

  • 1顾雅佳,肖勤.乳腺X线报告规范化——BI-RADS介绍[J].中国医学计算机成像杂志,2007,13(5):322-326. 被引量:50
  • 2National Comprehensive Cancer Network (NCCN). NCCN Clinical Practice Guidelines in Oncology, Breast Cancer Screening and Diagnosis vl.2011 [EB/OL]. [2011-8].http://www.nccn.org/ professionals/physician_gls/PDF/breast.pdf.
  • 3Skaane P, Hofvind S, Skjennald A. Randomized trial of screen-film versus full-field digital mammography withsoft-copy reading in population-based screening program: fol- low-up and final results of Oslo II study [J ]. Radiology,2007,244 (3):708-717.
  • 4Pisano ED, Gatsonis C, Hendrick E, et al.Diagnostic perfor- mance of digital versus film mammography for breast cancer screening[J]. N Engl J Med,2005, 353( 17):1773-1783.
  • 5Warner E, Messersmith H,Causer P, et al.Systematic review: us- ing magnetic resonance imaging to screen women at high risk for breast cancer [ J ].Ann Intern Med, 2008,148 (9) :671-679.
  • 6Oestreicher N, White E, Lehman CD, et al. Predictors of sensi- tivity of clinical breast examination (CBE) [J]. Breast Cancer Res Treat,2002,76 ( 1 ) :73 -81.
  • 7Bobo JK, Lee NC, Thames SF. Findings from 752, 081 clinical breast examinations reported to a national screening program from 1995 through 1998 [J]. J Natl Cancer Inst,2000, 92 (12): 971-976.
  • 8Kearney TJ, Airapetian S, Sarvazyan A, et al. Tactile breast im- aging to increase the sensitivity of breast examination [J ]. J Clin Oncol,2004,22(14S), 1037.
  • 9Itoh A, Ueno E, Tohno E, et al.Breast disease: Clinieal applica- tion of US elastography for diagnosis [Jl. Radiology,2006,239(2): 341-350.
  • 10Thomas A, Fischer T, Frey H, et ah Real-time elastography -- an advanced method of uhrasound: first results in 108 palients with breast lesions [J].Uhrasound Ohstet Gynecol,2006,28 (3): 335-340.

二级参考文献5

  • 1顾雅佳.规范乳腺X线报告[J].中华放射学杂志,2004,38(9):903-905. 被引量:46
  • 2顾雅佳,吴斌,张帅,杨天锡.使用乳腺影像报告和数据系统诊断乳腺疾病的体会[J].中华放射学杂志,2004,38(9):931-936. 被引量:27
  • 3American College of Radiology.Breast imaging reporting and data system (BI-RADS).4th edition.Reston (VA) 7 American College of Radiology,2003.
  • 4Bumside ES,Ochsner JE,Fowler KJ,et al.Use of microcalcification descriptors in BI-RADS 4th edition to stratify risk of malignancy.Radiology,2007,242:388-395.
  • 5Eberl MM,Fox CH,Edge SB,et al.BI-RADS classification for management of abnormal mammograms.J Am Board Fam Med,2006,19:161-164.

共引文献49

同被引文献162

引证文献14

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部