期刊文献+

锁定钢板与双切口双钢板内固定治疗复杂胫骨平台骨折的临床疗效对比分析 被引量:8

Analysis of the comparison of the clinical curative effect of locking plate and double incision double plate internal fixation for complex tibial plateau fracture
在线阅读 下载PDF
导出
摘要 目的:比较双切口双钢板与锁定钢板内固定治疗复杂胫骨平台骨折的疗效。方法:回顾性分析我院自2006年1月至2010年12月间治疗的112例复杂胫骨平台骨折患者的临床资料,其中52例行锁定钢板内固定治疗,为A组,60例行双切口双钢板治疗,为B组,观察比较两组的手术效果。结果:两组的手术时间、术中出血量、术后负重的时间、骨折愈合时间、住院时间的比较,差异无显著性(P>0.05)。经过随访,所有患者均取得了较好的疗效。两组患者的膝关节的功能恢复方面无显著差异性,不具有统计学意义(P>0.05)。结论:在治疗复杂胫骨平台骨折方面,锁定钢板内固定可以获得与双切口双钢板相似的治疗结果,临床治疗效果满意,值得在临床推广应用。 Objective:To compare the curative effect of of double incision double steel and locking plate internal fixation for complex tibial plateau fracture.Methods:A retrospective study of 112 patients who had clinical information with complex fracture of tibial plateau treated in our hospital since 1,2006~12,2010.52 patients were treated with routine locking plate fixation,as group A.60 patients were treated with routine double incision double steel treatment,as group B,observed and compared the operation effect for the two groups.Results:After the comparison of the operation time,peri-operative bleeding and postoperative load time,fracture healing time,time of hospitalization of the two groups,there were no significant difference(P0.05).After follow-up,all patients were achieved good effect.Two sets of patients without the knee functional recovery difference,not significant(P0.05).Conclusion:in the treatment of complicated tibial plateau fracture fixation,locking plate can obtain the similar treatment results as double incision double steel,can achive good clinical effect.it was worth of clinical promotion.
作者 王奉雷
出处 《中外妇儿健康(学术版)》 2011年第6期80-81,共2页
关键词 锁定钢板 双切口双钢板 内固定 复杂胫骨平台骨折 Locking plate Double incision double plate Internal fixation Complex tibial plateau fracture
  • 相关文献

参考文献7

二级参考文献37

  • 1葛志斌,张前法,庞清江.重组合异种骨加钢板内固定治疗胫骨平台骨折[J].中国修复重建外科杂志,2004,18(4):272-274. 被引量:13
  • 2肖睿,唐强,李伟,刘峰,刘勇,单旭彬.螺旋CT三维重建在胫骨平台骨折中的应用[J].中华创伤骨科杂志,2005,7(6):523-525. 被引量:39
  • 3徐建生,陈作人,陆凯.胫骨平台骨折外科术式的选择[J].中国骨伤,2006,19(7):426-427. 被引量:5
  • 4Rohit A, Martin L, Alfred H, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate[ J]. J Orthop Trauma,2007,5:316 - 322.
  • 5Jorge LO, Amel T. Current concepts in volar fixed-angle fixation of unstable distal radius fractures [ J ]. Clinical Orthopaedics and Related Research,2006,445:58 - 67.
  • 6Stamer DT,Schenk R,Staggers B,et al.Bicondylar tibial plateau fractures treated with a hybrid ring external fixator:a preliminary study.J Orthop Trauma,1994,8(6):455-461.
  • 7Mikulak SA,Gold SM,Zinar DM.Small wire external fixation of high energy tibial plateau fractures.Clin Orthop,1998,356:230-238.
  • 8Hutson JJ Jr,Zych GA.Infection in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators.J Orthop Trauma,1998,12(3):214-218.
  • 9Kumar A,Whittle AP.Treatment of complex (Schatzker Type Ⅵ) fractures of tibial plateau with circular wire external fixation:retrospective case review.J Orthop Trauma,2000,14(5):339-344.
  • 10Barei DP,Nork SE,Mills WJ,et al.Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique.J Orthop Trauma,2004,18(10):649-657.

共引文献273

同被引文献37

引证文献8

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史