利用自组装的气相色谱仪-电子捕获检测器系统(GC-ECD)测定大气中12种卤代温室气体,空气样品采样的时间分辨率80min,分析精度0.16%—4.87%,准确度-1.64%—3.05%.对2007年4月6日—2007年4月16日在北京上甸子站的观测结果进行分析,获得12种卤代温室气体的本底和非本底浓度,表明该系统适用于大气中卤代温室气体浓度在线观测。
A custom-made GC-ECD system was designed for on-site measurement of trace atmospheric halogenated greenhouse gases.The time resolution of air samples was one per 80 min.The precisions and accuracies are 0.16% —4.87% and-1.64% —3.05%,respectively.The results during 2007-04-06—2007-04-16 at Shangdianzi background station shows that the system can capture both background and pollution signals which proves that it can be used for on-site background atmospheric measurements of halogenated greenhouse gases.