期刊文献+

反平衡法测试核算220t/h电站锅炉热效率 被引量:1

Thermal Efficiency Calculation of 220 t/h Boiler in Power Station with Counter Balancing Method
在线阅读 下载PDF
导出
摘要 节能降耗、减少碳排放量是锅炉运行管理的关键。阐述了锅炉热效率的测试核算方法,分析了影响220t/h电站锅炉热效率原因,根据测试数据结合运行管理中存在的问题提出了提高锅炉热效率的改进措施。 Energy conservation,consumption reduction,and reduction of carbon emission is the key to boiler operation management.The calculation method for testing the boiler thermal efficiency is described,the causes influencing the thermal efficiency of the 220 t/h boiler in power station are analyzed,and based on the testing data and existing problems in the operation management,the improvement measures to increase the boiler thermal efficiency are proposed.
作者 蔡利兵
出处 《硫磷设计与粉体工程》 2010年第4期31-34,共4页 Sulphur Phosphorus & Bulk Materials Handling Related Engineering
关键词 电站锅炉 热效率 测试 反平衡法 原因分析 改进措施 power station boiler thermal efficiency testing counter balancing method cause analysis improvement measure
  • 相关文献

参考文献1

  • 1山西省电力工业局.锅炉设备运行[M].北京:中国电力出版社,1997.

共引文献3

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部