期刊文献+

建筑节能墙体砌块空心率的热反应分析 被引量:5

Thermal response analysis on blocks hollow rate of building energy conservation
在线阅读 下载PDF
导出
摘要 为了研究不同空心率条件下三排孔混凝土墙体砌块的动态传热特性,应用反应系数法,通过分析空心率为22.81%-52.14%空心砌块内侧的壁面反应温度,认为当空心率为42.36%-47.25%时,围护墙体的热特性才能达到节能墙体的要求,并采用热箱法对三排孔混凝土墙体砌块热阻的实验研究,证明了只有当空心率为42.36%-47.25%时,热阻值才能基本满足节能的要求,同时验证了理论研究的合理性。 To research the dynamic thermal properties of concrete masonry building blocks with three lines of different holes, the thermal response factor method was used in conditions of different hollow rates. By response temperature analysis of the blocks' inner side with the hollow rates from 22.81% to 52.14%, the thermal properties of the envelop wall could meet the requirements when the hollow rate was among 42.36%-47.25%. The thermal box experiment results prove that only when the hollow rate ranges among 42.36%-47.25%, the thermal resistance can meet the requirements, and that the theoretical research is rational.
出处 《解放军理工大学学报(自然科学版)》 EI 北大核心 2009年第6期623-627,共5页 Journal of PLA University of Science and Technology(Natural Science Edition)
基金 江苏省自然科学基金资助项目(BK2008369)
关键词 墙体砌块 空心率 热反应系数 热阻 building blocks hollow rate thermal response factor thermal resistance
  • 相关文献

参考文献6

二级参考文献16

  • 1李建成.砼空心砌块的孔型对其隔热性能的影响[J].建筑砌块与砌块建筑,1996(3):2-5. 被引量:6
  • 2中原信生.建筑和建筑设备的节能[M].北京:中国建筑工业出版社,1990.1-2.
  • 3中华人民共和国建设部.民用建筑热工设计规范[M].北京:中国计划出版社,1993,GB50176-93.63-65.
  • 4中华人民共和国建设部.GB50176-93.民用建筑热工设计规范[S].
  • 5Barakat S A. Experimental determination of the Z-transfer function coefficients for houses[J]. ASHRAE, 1987, 93( part I):146~147.
  • 6彦启森,建筑热过程,1986年,45页
  • 7中华人民共和国建设部,民用建筑热工设计规范,1993年,63页
  • 8中原信生建筑和建筑设备的节能,1990年,1页
  • 9陈沛霖,空气调节负荷计算理论与方法,1987年,87页
  • 10杨世铭.传热学[M].北京:高等教育出版社,1987..