期刊文献+

阻抗板探测器工作电压和时间分辨率的测量及分析

Test and Analysis of Operation Voltage and Time Resolution of Resistive Plate Chamber
在线阅读 下载PDF
导出
摘要 在不同工作电压下对阻抗板探测器(resistive plate chamber,RPC)的信号进行了测试,并根据信号幅度的大小和形状判断出产生雪崩信号和流光信号的电压区域。研究了气体成分和工作电压对RPC时间分辨率的影响。时间分辨率随电压的增加先下降后上升,时间分辨率有最低点,随SF6气体比例的增加,时间分辨率最低点的电压向前移动了200 V。当电压为10.2 kV、φ(SF6)=1.3%时,时间分辨率有最理想值。 The signals from the resistive plate chamber (RPC) were tested under different operation voltages. According to the amplitude and shape of the signals, the operation voltages for avalanche signals and streamer signals were determined respectively. The influence of the operation gas mixture and high voltage on the time resolution was also investigated. The time resolution first decreases with the increase of voltage and then goes up again. There is a minimum value of time resolution. The minimum of time resolution shifts forward for 200 V with the increase of the ratio of SF6. At voltage 10.2 kV and φ(SF6)=1. 3%, the time resolution reaches its optimized value.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2009年第5期466-469,共4页 Atomic Energy Science and Technology
基金 国家自然科学基金资助项目(10605040,10875174,10635020)
关键词 阻抗板探测器 雪崩信号 流光信号 时间分辨率 resistive plate chamber avalanche signal streamer signal time resolution
  • 相关文献

参考文献3

  • 1YINGJ, YEYL, BANY, et al. Beam test resuits of a resistive plate chamber made of Chinese bakelites[J]. Nucl Instrum Methods A, 2001, 459(3): 513-522.
  • 2HONGB, HONGSJ, LEEKS, etal. Endcap resistive plate chambers for the compact muon solenoid experiment [J]. Journal of the Korean Physical Society, 2006, 48(4): 515-529.
  • 3马经国,班勇,刘洪涛,叶沿林,蔡建新,狄振宇,应军,贾晴鹰.大面积阻抗板探测器的研制及性能测量[J].高能物理与核物理,2001,25(9):898-902. 被引量:5

二级参考文献2

  • 1Ying J,Nucl Instr Method Phys Res.A,2001年,459卷,513页
  • 2Ying J,J Phys G Nucl Part Phys,2000年,26卷,1291页

共引文献4

相关作者