期刊文献+

温湿度独立控制空调系统CFD模拟及实验研究 被引量:3

CFD Simulation and Experimental Research on Humiture Independent Control System
在线阅读 下载PDF
导出
摘要 温湿度独立控制系统是一种新型的空调方式,即置换通风及辐射顶板结合的空调方式。分析比较了这种空调系统的工作原理、特点及经济性,重点分析了系统独特的节能优势,通过测试假想平面网格节点上的温度,以及空间各点的风速,评价了这种空调系统的热舒适性,研究表明:可以得到适中的完全可以接受的室内空气品质和舒适性。 Humiture independent control system is one kind of late-model air-conditioning way, which is combined of displacement system and cooling ceiling panel. The principle and characteristic of this air-conditioning system were analyzed, especially the energy conservation. Based on the measurement of air velocity and temperatures, this kind of air-conditioning system's thermal comfortableness has being appraised, which may obtain the moderate completely acceptable indoor air quality and comfortableness.
作者 王立雷 赵菊
出处 《建筑热能通风空调》 2009年第1期40-42,39,共4页 Building Energy & Environment
关键词 温湿度独立控制 置换通风 辐射顶板 热舒适性 humiture independent control system, displacement ventilation, radiant ceiling panel, thermal comfortableness
  • 相关文献

参考文献8

二级参考文献14

  • 1李银明,黄翔.蒸发冷却与冷却吊顶相结合的半集中式空调系统的探讨[J].流体机械,2005,33(1):56-59. 被引量:16
  • 2GB50189-2005.公共建筑节能设计标准[S].[S].,2005..
  • 3Yuan Xiaoxiong,AHSRAETRANS,1998年,78页
  • 4JAE-WEON JEONG.Energy conservation benefits of a dedicated outdoor air system with parallel sensible coolling by ceiling radiant panels[A].ASHRAE Transactions[C].2003.
  • 5STANLEY A MUMMA.Ceiling panel cooling systems[A].ASHRAE Journal[C].2001.
  • 6KURT W ROTH,DETLEF WESTPHALEN,JOHN DIECKMANN,SEPHIR D HAMILTON,WILLIAM GOETZLER.Energy consumption characteristics of commercial building HVAC systems.volume Ⅲ:energy savings potential[M].2002.
  • 7CORINA STETIU.Radiant cooling in US office buildings:Towards eliminating the perception of climate-imposed barriers[R].Energy and Resources Group,University of California,Berkeley and Environmental Energy Technologies Division,Lawrence Berkeley National Laboratory,University of California Berkeley,CA 94720.1998.
  • 8DONALD P GATLEY.Dehumidification enhancements for 100-percentoutside-air AHUs[A].Heating/Piping/Air Conditioning Engineering[M].2000.
  • 9STANLEY A MUMMA.Achieving dry outside air in an energy-efficient manner[Z].
  • 10ASHRAE.Chapter 6-Panel heating and cooling[A].Systems and Equipment Bandbook[M].2000.

共引文献52

同被引文献28

  • 1向灵均,吴蔚兰,张华廷.双冷源温湿度独立控制系统在电子洁净厂房中的应用[J].建筑科学,2012,28(S2):161-165. 被引量:6
  • 2马艺然;李德英.温湿度独立控制系统的适用性分析[J]建筑热能通风空调,2011140-141.
  • 3杨修飞;罗清海.温湿度独立控制空调系统的现状分析[J]使用节能技术.
  • 4苏鹏;喻李葵.转轮除湿空调系统研究进展[J]建筑热能通风空调,2009477-481.
  • 5路诗奎;张小松.溶液除湿与辐射供冷热式独立处理空调系统[J]化工学报,2006(增刊):101-105.
  • 6姜毅.智能端子箱防凝露控制器的研制与实验研究[A],2010.
  • 7连之伟;陈宝明;齐庆梅.热值交换原理与设备[M]{H}北京:中国建筑工业出版社,2006.
  • 8傅秦生;赵小明;唐桂华.热工基础与应用[M]{H}北京:机械工业出版社,2006.
  • 9李毅.浅谈凝露对变电站设备的危害和防护措施[J]科海故事博览@科技探索,2012(09).
  • 10陈国林.浅谈通风空调几项新技术[J].工程与建设,2008,22(4):509-511. 被引量:4