摘要
本文主要介绍了所开展的梁柱组合节点的拟动力试验,梁柱连接采用高强度螺栓平端板形式。试验采用经过调幅的具有不同地震加速度峰值的Ispara地震动作为激励进行加载,对试件在地震作用下的加速度反应、位移反应、滞回性能、刚度和耗能进行分析,对试验现象和结果进行了比较详细的阐述和分析。
This paper is concerned with the tests on composite beam-to-column joints subject to low cyclic loads. The beam-to-column steelwork connections were made of bolted flush end plate. The specimen was subjected to nine tests of increasing magnitude based on the Ispara ground motion. Dynamic responses including acceleration,displacement, varying stiffness, hysteretic behavior and energy dissipation corresponding to input excitation are discussed. Detailed test observations and results were reported.
出处
《地震工程与工程振动》
CSCD
北大核心
2008年第6期124-133,共10页
Earthquake Engineering and Engineering Dynamics
基金
国家杰出青年基金项目(50225825)
土木工程防灾国家重点试验室开放课题资助项目
关键词
平端板连接
组合节点
拟动力
节点性能
弯矩-转角关系
flush end plate
composite joint
pseudo dynamic
joint behavior