Optimised Calibration Method for Six-Port Junction

Optimised Calibration Method for Six-Port Junction
在线阅读 下载PDF
导出
摘要 A dual-tone technique is used to produce multi-samples in optimising calibration of six-port junction. More accurate results are achieved by using the least-square method and excluding those samples which may cause bigger errors. A 0.80 -1.10 GHz microwave integrated circuit (MIC) six-port reflectometer is constructed. Nine test samples are used in the measurement. With Engen's calibration procedure, the difference between the HP8510 and the six-port reflectrometer is in the order of 0.20 dB/1.5° for most cases, above 0.50 dB/5.0° at boundary frequency. With the optimised method, the difference is less than 0. 10 dB/1.0° for most cases, and the biggest error is 0.42 dB/2.1° for boundary frequencies. A dual-tone technique is used to produce multi-samples in optimising calibration of six-port junction. More accurate results are achieved by using the least-square method and excluding those samples which may cause bigger errors. A 0.80 -1.10 GHz microwave integrated circuit (MIC) six-port reflectometer is constructed. Nine test samples are used in the measurement. With Engen's calibration procedure, the difference between the HP8510 and the six-port reflectrometer is in the order of 0.20 dB/1.5° for most cases, above 0.50 dB/5.0° at boundary frequency. With the optimised method, the difference is less than 0. 10 dB/1.0° for most cases, and the biggest error is 0.42 dB/2.1° for boundary frequencies.
出处 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期392-397,共6页 西南交通大学学报(英文版)
基金 The National Natural Science Foundation of China (No.60441006)
关键词 Six-port junction Calibration method Dual-tone technique Six-port junction Calibration method Dual-tone technique
  • 相关文献

参考文献10

  • 1Engen G F.An improved circuit for implementing the six- port technique of microwave measurements [ J][].IEEE Transactions on Magnetics.1977
  • 2Engen G F,Hoer C A.Thru-reflect-line: an improved technique for calibrating the dual six-port automatic net- work analyzer[].IEEE Transactions on Magnetics.1979
  • 3Garcia B A,Miguelez C G,Huyart B, et al.Application of six-port technique in a radar system[].Proc of Progress in Electromagnetics Research Symposium.2000
  • 4Hodgetts E T,Criffin E J.A united treatment of the the-ory of six-port reflectometer calibrations using the mini- mum of standards[]..1983
  • 5Stumper U.Finding initial estimates needed for the engen method of calibrating a single six-port reflectometer[].IEEE Transactions on Magnetics.1990
  • 6Potter C M,Hjipieris G.A robust six-to four-port reduc- tion algorithm[].Microwave Symposium Digest.1993
  • 7Chahine S A,Huyart B,Achkar J.Reflectometer cali- bration without an open circuit[].IEEE Transactions on Instrumentation and Measurement.2003
  • 8Molina-Fernández,et al.Planar lightwave circuit six-port tech-nique for optical measurements and characterizations[].Journalof Lightwave Technology.2005
  • 9Hsin Chia Lu,Tah Hsiung Chu.Microwave Diversity Imaging Using Six-port Reflectometer[].IEEE Transactions on Microwave Theory and Techniques.1999
  • 10Ji Li Renato G,Bosisio Ke Wu.Dual-tone calibration of six-port junction and its application to the Six-Port direct digital millimetric receiver[].IEEE Transactions on Microwave Theory and Techiques.1996

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部