期刊文献+

PMMA人工晶状体表面的CF4/O2等离子体修饰 被引量:3

Surface Modification of PMMA IOL by CF_4/O_2 RF-plasma
在线阅读 下载PDF
导出
摘要 为了改善聚甲基丙烯酸甲酯(PMMA)人工晶状体的生物相容性和透光性,采用CF4/O2等离子体技术修饰其表面.通过衰减全反射红外光谱(ATR-FTIR)、X射线光电子能谱(XPS)、静态接触角(CA)测定、扫描电子显微镜(SEM)、紫外-可见近红外光谱(UV-Vis)等方法进行表征,结果表明,经CF4/O2等离子体处理后,PMMA表面的含氟和含氧基团增加,其表面的亲水性增强,生物相容性改善,紫外光的隔离效率增大.因此,通过CF4/O2等离子体修饰能够有效地改善PMMA人工晶状体的性质. To improve biocompatibility and transmittance of polymethyI methacrylate intraocular lens (PMMA IOL), the surface of PMMA IOL was treated by CF4/O2 redio-frequency(RF)-plasma. The modified PMMA IOLs were characterized by the attenuated total reflectance Fourier transfer infrared spectroscopy( ATR-I^HR), X-ray photoelectron spectroscopy( XPS), the contact angle (CA) measurement, scanning electron microscopy (SEM) and ultraviolet-visible spectroscopy (UV-Vis), respectively. The results indicated that the treatment of CF4/O2 RF-plasma could make the modified PMMA IOL not only increase the contents of fluorine and oxygen, hydrophilicity and anti-ultroviolet radiation but also improve biocompatibility. Based on these results, the treatment of CF4/O2 RF-plasma is an effective method to improve the performance of PMMA IOL.
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2008年第9期1854-1858,共5页 Chemical Journal of Chinese Universities
基金 国家自然科学基金(批准号:10675078)资助
关键词 PMMA人工晶状体 CF4/O2 等离子体处理 生物相容性 透光性 PMMA IOL CF4/O2 Plasma treatment Biocompatibility Transmittance
  • 相关文献

参考文献26

二级参考文献61

  • 1石海红,管怀进.人工晶状体的设计对后囊膜混浊的影响[J].国际眼科杂志,2004,4(5):882-886. 被引量:12
  • 2张其清,任磊,袁平,王淳,刘玲蓉,胡建芳,钱露茜,郭淑静.低温等离子体对天然胶原材料表面改性的研究[J].材料研究学报,1994,8(6):551-554. 被引量:12
  • 3朱如瑾,黄枫,刘永盛,黄家湛.聚丙烯-胰蛋白酶膜的制备与性能[J].高分子材料科学与工程,1994,10(2):116-120. 被引量:5
  • 4应锡璋,王蓓蓓,姚诗凯,朱建国,朱立红,邵慧珍,马挺,姚洪熹.一种新颖的抗血栓材料的研究[J].高等学校化学学报,1996,17(5):815-819. 被引量:10
  • 5喻凯.血浆蛋白质与人体硬组织替代材料的生物相容性[R].华西医科大学博士后研究工作报告,..
  • 6[1]Hollick EJ,Spalton DJ,Ursell PG,et al.Biocompatibility of poly(methyl methacrylate),silicone,and AcrySof intraocular lenses: randomized comparison of the cellular reaction on the anterior lens surface.J Cataract Refract Surg,1998,24:361
  • 7[2]Samuelson TW,Chu YR,Kreiger RA.Evaluation of giant-cell deposits on foldable intraocular lenses after combined cataract and glaucoma surgery.J Cataract Refract Surg,2000,26:817
  • 8[3]Amon M,Menapace R,Radax U,et al.In vivo study of cell reactions on poly(methyl methacrylate)intraocular lenses with different surface properties.J Cataract Refract Surg,1996,22:825
  • 9[4]Ravalico G,Baccara F,Lovisato A,et al.Postoperative cellular reaction on various intraocular lens materials.Ophthalmology,1997,104:1084
  • 10[5]Flynn WJ,Carlson DW.Laser synechialysis to prevent membrane recurrence on silicone intraocular lenses.Am J Ophthalmol,1996,122(9):426

共引文献44

同被引文献45

引证文献3

二级引证文献15