期刊文献+

缺氧/好氧膜生物反应器处理味精废水的研究 被引量:3

Research on monosodium glutamate waste water treated by A/O membrane bioreactor
在线阅读 下载PDF
导出
摘要 采用缺氧/好氧膜生物反应器处理高COD、高氨氮的味精废水.实验分两个阶段:第一个阶段保持污泥浓度为6 000 mg/L左右,HRT 48 h;向系统内投加Na2CO3调节碱度.运行结果显示COD的去除率在90%左右,最高达到96%;氨氮的去除率在95%左右,甚至达到100%.第二个阶段保持其他条件不变,停止向系统内投加Na2CO3,结果表明,停止调节系统碱度对COD的去除影响不大,而对氨氮的去除有较大影响.实验结果表明,缺氧/好氧膜生物反应器具有较强的抗冲击负荷能力,对味精废水的COD和氨氮有很好的去除效果. The treatment of high COD and high ammonia monosodium glutamate waste water by A/O MBR is studied. The experiment can be divided into two stages: one is MLSS: 6 000 mg/L, HRT: 48 h and adding Na2CO3 into system. Under this condition, the removal of COD by MBR can reach 90%, even to 96% ,and the removal of ammonia is 95%-100%. The other stage is to stop adding Na2CO3 into the system without changing other conditions, which has a great influence on ammonia removal and has a little influence on COD removal. The experimental results show that A/O MBR has a good ability of preventing fluctuation of load and can remove COD and ammonia effectively.
出处 《天津工业大学学报》 CAS 2008年第3期74-76,共3页 Journal of Tiangong University
基金 2000t/d味精废水MBR深度处理项目(合同编号:MHWJ-MBR-070403)
关键词 膜生物反应器 味精废水 污水处理 氨氮 MBR monosodium glutamate waste water treatment ammonia
  • 相关文献

参考文献3

二级参考文献47

共引文献208

同被引文献30

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;