期刊文献+

64层螺旋CT在冠状动脉搭桥术后的应用价值 被引量:2

The application value of 64-multislice CT in coronary artery bypass grafts
在线阅读 下载PDF
导出
摘要 目的:探讨64层螺旋CT在冠状动脉搭桥术后的临床应用价值。方法:采用西门子Somatom Sensation Cardiac64螺旋CT对22例冠脉搭桥术后的患者(共计44根桥血管)进行了扫描,其中11例患者同时进行了冠状动脉造影检查。结果:64层螺旋CT显示22例患者发现44支桥血管,显示率100%。44支桥血管中,33支(75%)通畅、5支(11.4%)闭塞、3支(6.8%)中重度狭窄、3支(6.8%)轻度狭窄。与冠脉造影对照,诊断桥血管明显狭窄及闭塞的敏感性100%,特异性92.9%,阳性预测值87.5%,阴性预测值100%,准确率95.2%。结论:64层螺旋CT是评价桥血管闭塞及狭窄的可靠方法。 Objective: To evaluate the value of 64-multislice CT for assessment of coronary artery bypass grafts(CABG). Methods-22 patients after CABG with 44 bypass grafts were examined with 64-multislice CT, 11 of them were performed with coronary angiography. All grafts were assessed by two observers in consensus. Consensus reading was compared with coronary angiography. Results-22 patients with a total of 44 bypass grafts were investigated by 64-multislice CT. Overall, 44 grafts (100%) were assessable with 64-multishce CT. CT showed that 33 grafts (75 % ) were patent and 5 grafts ( 11.4 % ) were occluded, 3 grafts were highgrade stenoses (6.8 % ). The assessment of stenosis or occlusion of bypass grafts resulted in a sensitivity of 100%, specificity of 92.9%, and positive and negative predictive values of 87.5% and of 100%, respectively. Conclusion:64-slice CT is a reliable method for the assessment of bypass graft patency and stenoses.
出处 《医学影像学杂志》 2007年第12期1264-1266,共3页 Journal of Medical Imaging
关键词 冠状动脉造影 冠状动脉搭桥术 体层摄影术 X线计算机 Coronary angiography Coronary artery bypass grafts Tomography, X-ray computed
  • 相关文献

参考文献7

  • 1Cameron AA,Davis KB,Rogers WJ.Recurrence of angina after coronary artery bypass surgery:predictors and prognosis (CASS registry)[J].J Am Coll Cardiol,1995,26:895-899.
  • 2Fitzgibbon GM,Kafka HP,Leach AJ,et al.Coronary bypass graft fate and patient outcome:angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years[J].J Am Coll Cardiol,1996,28:616-626.
  • 3Pannu HK,Flohr TG,Corl FM,et al.Current concepts in multi-detector row CT evaluation of the coronary arteries:principles,techniques[J].Radiographics,2003,23:111-125.
  • 4Ropers DS,Ulzheimer E,Wenkel,et al.Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction[J].Am J Cardiol,2001,88:792-795.
  • 5Martuscelli E,Romagnoli A,D'Eliseo D,et al.Evaluation of venous and arterial conduit patency by 16-slice spiral computed tomography[J].Circulation,2004,110:3234-3238.
  • 6Kuettner A,Trabold T,Schroeder S,et al.Noninvasive detection of coronary lesions using 16-detector mltislice spiral computed tomography technology:initial clinical results[J].J Am Coll Cardiol,2004,44:1230-1237.
  • 7Hausleiter J,MeyerT,HadamitzkyM,etal.Prevalence of noncalcified coronary plaques by 64-slice computed tomography in patients with an intermediate risk for significant coronary artery disease[J].J Am Coll Cardiol,2006,48:312-318.

同被引文献20

  • 1肖喜刚,韩雪,王雪红,孙宏亮,王鸿振,牛洪涛.多层螺旋CT冠状动脉成像在冠心病中的临床应用[J].中华放射学杂志,2004,38(9):957-961. 被引量:66
  • 2FITZGIBBON GM, KAFKA HP, LEACH AJ, et al. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years[J]. J Am Coll Cardiol, 1996, 28(3): 616-626.
  • 3NIEMAN K, RENSING B J, VAN GEUNS RJ, et al. Non-invasive coronary angiography with muhislice spiral computed tomography: impact of heart rate[J]. Heart, 2002, 88(8): 470-474.
  • 4BUNCE NH, LORENZ CH, JOHN AS, et al. Coronary artery bypass graft pateney: assessment with true fast imaging with steady-state precession versus gadolinium-enhanced MR angiography[J]. Radiology, 2003, 227(2): 440--446.
  • 5PANNU HK, FLOHR TG, CORL FM, et al. Current concepts in multi-detector row CT evaluation of the coronary arteries: principles, techniques[J]. Radiographics, 2003, 23: 111-125.
  • 6ROPERS DS, ULZHEIMER E, WENKEL, et al. Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrecardiographic-gated image reconstruction [J]. Am J Cardiol, 2001, 88(7): 792-795.
  • 7NIEMAN K, RENSING B, VAN GEUNS R, et al. Non-invasive coronary angiography with muhislice spiral computed tomography: impact of heart rate[J]. Heart, 2002, 88(5): 470-474.
  • 8HOFFMANN MH, SHI H, MANZKE R, et al. Noninvasive coronary angiography with 16-detector row CT: effect of heart rate[J]. Radiology, 2005, 234(1): 86-97.
  • 9HAUSLEITER J, MEYER T, HADAMITZKY M, et al. Prevalence of noncalcified coronary plaques by 64-slice computed tomography in patients with an intermediate risk for significant coronary artery disease [J]. J Am Coll Cardiol, 2006, 48(2): 312-318.
  • 10Hoye A, Lemos PA, Arampatzis CA, et al. Effectiveness of the sirolimus-eluting stent in the treatment of patients with a prior history of coronary artery bypass graft surgery [J]. Coron Artery Dis, 2004, 15(3): 171-175.

引证文献2