现浇梁钢筋保护层厚度检测中几种不利位置分析 被引量:4

Analysis about several kinds of unfavorable positions in testing of the thickness of protective coating for steel bar in cast-in-situ beam
在线阅读 下载PDF
导出
摘要 通过对大量结构实体钢筋保护层厚度的监督检测,特别是现浇梁类构件中几种不利检测位置进行研究分析,一方面,检测者在检测时应合理避开该位置,避免这些偶然性因素导致的误判,以使检测具有代表性;另一方面,提出对某些不利位置应通过钢筋安装质量的提高及构造要求来得到解决,使钢筋保护层厚度符合要求以减少对结构的不利影响。 Base on the supervision and test for the thickness of protective coating of steel bar in engineering structure body, especially in cast-in-situ beam, several kinds of positions that adverse to testing are researched and analysed. On one hand, those in charge of testing should rationally avoid these positions and avoid the erroneous judgement that caused by the haphazard factor, in order to make the test representative. On the other hand, propose the solutions to these positions improving the install quality of steel bar and improving the structure requirement, make the thickness of protective coating conform to requirement so the adverse influence to structure can be reduced.
作者 张福生
出处 《工程质量》 2007年第11期15-17,共3页 Construction Quality
关键词 结构实体 钢筋保护层 厚度检测 不利位置 structure body, protection layer of steel bar, thickness testing, unfavorable position
  • 相关文献

同被引文献17

  • 1蒋利学,陆伟杰.混凝土结构中钢筋保护层厚度的控制[J].工业建筑,2005,35(z1):179-183. 被引量:28
  • 2徐有邻,刘刚,程志军,王晓锋.混凝土结构中钢筋保护层厚度的检验[J].施工技术,2005,34(4):78-80. 被引量:19
  • 3张福生.结构实体钢筋保护层厚度检测工作的探讨[J].工程质量,2006,24(3):10-12. 被引量:9
  • 4GB50204-2002混凝土结构工程施工质量验收规范[S].北京:中国建筑工业出版社,2002.
  • 5JGJ/T152-2008,混凝土中钢筋检测技术规程[S].北京:中国建筑工业出版社,2008.
  • 6清华大学.GB/T50476-2008混凝土结构耐久性设计规范[S].北京:中国建筑工业出版社,2009.
  • 7江苏南通六建建设集团有限公司.JGJ/T219-2010混凝土结构用钢筋间隔件应用技术规程[S].北京:中国建筑工业出版社,2011.
  • 8中国建筑科学研究院.JGJ/T152--2008混凝土中钢筋检测技术规程[S].北京:中国建筑工业出版社,2008.
  • 9中国建筑科学研究院.GB50010-2010混凝土结构设计规范[M].北京中国建筑工业出版社,2010.
  • 10张川,白绍良,钱觉时,等译.美国房屋建筑混凝土结构规范(ACl318-05)及条文说明(ACl318R-05)[M].重庆:重庆大学出版社,2007.