摘要
研究并联电容与电网谐波之间的相互影响,指出在采用并联电容进行无功补偿时,必须考虑电容对电网谐波的放大和谐波对电容的严重危害.
In this paper, the author researches into the mutual effects between shunt capactor and powernet harmonics and points out that when the reactive power has been compen sated by uslng shunt capacitor, it is necessary to consider the capacitor's amplification of powernet harmonics and the harmonics' serious harms to capacitors.
出处
《兰州铁道学院学报》
1997年第1期68-72,共5页
Journal of Lanzhou Railway University
关键词
并联电容器
谐波
无功补偿
电网
shunt capacitors
harmonics
reactive compensation
electric reactors