期刊文献+

影响准分子激光原位角膜磨镶术术后眼压的重要参数 被引量:1

An Investigation on the Important Parameters that Affect Intraocular Pressure after Laser in Situ Keratomileusis for Myopia
在线阅读 下载PDF
导出
摘要 目的探讨准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)治疗近视眼术后非接触眼压测量值(intraocular pressure,IOP)的变化及其相关因素。方法 393例(760眼)施行 LASIK 术的近视患者手术前、后3个月的 IOP 的差值(the underestimation of IOP,AP)与所矫正的等效球镜度数(spherical equiva-lent dioptre,D),术前中央角膜厚度(central corneal thickness,CCT),术前 IOP,术前角膜前表面曲率(cornealcurvature,K),切削深度(ablation depth,T),术前和术后3个月的角膜曲率差(change of corneal curvature,△K),年龄和性别等因素进行相关分析和多元逐步回归分析。结果△P与 D(r=0.380,P=0.000),术前 CCT(r=0.224,P=0.000),IOP(r=0.657,P=0.000),K(r=0.126,P=0.001),T(r=0.389,P=0.000),△K(r=0.363,P=0.000)均有显著相关性。术前 IOP 是影响△P最重要的参数。多元逐步回归分析得出回归方程:AP=~7.722+0.029 T+0.582 IOP-0.005 CCT+0.116 K。结论术前 IOP 是影响 LASIK 治疗近视后 IOP 测量偏低的最重要参数,实际 IOP 越高,LASIK 治疗近视术后 IOP 测量偏低的量也越大。(中国眼耳鼻喉科杂志,2007,7:220-221) Purpose To explore the changes in intraocular pressure (IOP) and affecting parameters after laser in situ keratomileusis (LASIK) for myopia. Methods In this prospective study, 760 eyes of 393 patients who underwent LASIK were included. Spherical equivalent dioptre (D), preoperative central corneal thickness (CCT), preoperative IOP, preoperative corneal curvature(K), ablation depth (T), change of corneal curvature (△K), patient age and sex were analyzed to determine the contribution and correlation to the underestimation of IOP(△P). Results D ( r = 0. 380,P =0. 000), preoperative CCT ( r = 0. 224, P = 0. 000 ), preoperative IOP ( r = 0. 657, P = 0.000 ), K ( r = 0. 126, P = 0. 001 ) ,T( r =0. 389 ,P =0. 000), △K( r =0. 363 ,P =0. 000) were statistically significant for △P. The preoperative IOP level is the most important parameter that affect △P. The regression equation obtained was △P = - 7. 722 + 0. 029 T + 0. 582 IOP - 0. 005 CCT + 0. 116 K. Conclusion The preoperative IOP level is the most important parameter that affect the underestimation of IOP after LASIK for myopia. The higher the preoperative IOP is, the higher the underestimation of IOP is.
出处 《中国眼耳鼻喉科杂志》 2007年第4期220-221,I0002,共3页 Chinese Journal of Ophthalmology and Otorhinolaryngology
关键词 准分子激光原位角膜磨镶术 眼压 非接触眼压计 laser in situ keratomileusis intraocular pressure non-contact tonometer
  • 相关文献

参考文献5

二级参考文献30

  • 1胡茂生 刘淳诗.非接触式眼压计与Goldmann氏压平眼压计对比研究[J].中华眼科杂志,1985,:111-111.
  • 2Shieds MB, The non-contact tonometer, Its value and limitations,Surv Ophthalmol, 1980, 24:211.
  • 3Whitacre MM et al. Am J Opthalmol, 1993, 115:592.
  • 4Ehlers N, BransenT, Sperling S, Applanation tonometry and central corneal thickness Acta Ophthalmol, 1975, 53: 34- 43.
  • 5Wolfs RCW et al. Am J Ophthalmol, 1997, 123:767.
  • 6Shah S, Ophthalmolgy, 2000, 107:1805.
  • 7Johnson M et al. Arch Ophthalmol, 1978, 96:664.
  • 8Mark HH. Corneal curvature in applanation tonometry[J]. Am J Ophthalmol,1973,76(2):2234.
  • 9Goldmann H. Un nouveru tonometre a applantion[J]. Bull Merm Soc Fr Ophthalmol,1954,67(4):474.
  • 10Fournier AV,Podetenev M,Lemire J,et al. Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis[J]. J Cataract Refract Surg,1998,24(7):905.

共引文献20

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部