期刊文献+

重庆某地源热泵系统冬季供热能力实验研究 被引量:3

The Experiment Research on Heating Capacity of Ground Source Heat Pump in Chongqing's Winter
在线阅读 下载PDF
导出
摘要 本文对地源热泵系统在间歇和连续两种运行工况下进行了对比实验研究。研究结果表明,在间歇运行工况下,供热性能系数COP平均值为4.468;在连续运行工况下,供热性能系数COP平均值为3.480。由此认为在重庆地区应用地源热泵系统冬季供热具有很高的节能价值。 The experimental research of Ground Source Heat Pump (GSHP) system on the two kinds of operating mode which are intermittent and continuous running is compared. The result shows: under the intermittent operation mode, the average value of COP is 4.468; under the continuous operating mode, the average value of COP is 3.480. So it has the very high value of energy conservation to apply GSHP system for heating in Chongqing's winter.
出处 《建筑热能通风空调》 2007年第3期45-47,88,共4页 Building Energy & Environment
基金 国家"十五"科技攻关项目(2003BA808A19-6)
关键词 地源热泵 供热能力 间歇运行 连续运行 ground source heat pump, heating capacity, intermittent operation, continuous running
  • 相关文献

参考文献1

  • 1地源热泵系统工程技术规范[S].广东:广东省建筑科学研究院,2006

同被引文献14

  • 1范萍萍,端木琳,舒海文,王学龙.地温可恢复性对土壤源热泵运行的影响[J].制冷与空调,2006,6(1):79-82. 被引量:14
  • 2Bi Y H,Chen L G,Wu C H.Ground heat exchanger temperature distribution analysis and experimental verification[J].Applied Thermal Engineering,2002,22(2):183-189.
  • 3Stevens James W.Coupled conduction and intermittent convective heat transfer from a buried pipe[J].Heat Transfer Engineering,2002,23(4):34-43.
  • 4GB50366-2009,地源热泵系统工程技术规范[s].
  • 5GB5Q019——2003,采暖通风与空气调节设计规范[S].
  • 6GBJ 19-87.采暖通风与空气调节设计规范[S].北京:中国计划出版社,1989
  • 7李善化 康慧 孙相军.火力发电厂及变电所供暖通风空调设计手册[M].北京:中国电力出版社,2000..
  • 8GB/T19409-2003水源热泵机组[S].
  • 9刘文学,唐志伟,魏加项,张宏宇,马重芳.地源热泵间歇制热运行的试验研究[J].可再生能源,2008,26(1):59-61. 被引量:15
  • 10王明国,付祥钊,王勇,刘勇,陈金华,臧子旋.利用长江水作水源热泵冷热源的探讨[J].暖通空调,2008,38(4):33-34. 被引量:15

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部