期刊文献+

低压配电网中性点接地方式的仿真 被引量:5

Simulation of Neutral Ground Modes for Low Voltage Distribution Grid
在线阅读 下载PDF
导出
摘要 介绍了配电网的3种接地方式(不接地、经电阻接地、谐振接地),分析了不同接地方式的原理和特点,利用ATP-EMTP仿真软件对35kV配电网的接地方式进行了仿真比较,指出了中性点经消弧线圈并联大电阻接地方式是目前比较好的接地方式。 The paper introduces the three grounding modes of distribution network,namely the non-grounded mode,the neutral grounding mode via resistance and the neutral grounding mode via arc suppression coil. The principle and characteristic of each grounding mode is analyzed. The several grounding modes of 35 kV distribution grid are simulated and compared by the ATP-EMTP software, and the neutral grounding mode via extinction coils in parallel connection with big resistances is indicated as a good mode at present.
出处 《江苏电机工程》 2007年第3期27-30,共4页 Jiangsu Electrical Engineering
关键词 配电网 接地方式 ATP-EMTP仿真 distribution network grounding mode ATP-EMTP simulation
  • 相关文献

参考文献5

  • 1倪虹妹 周军.电网中性点经电阻接地浅析.江西电力,2001,5(10):23-25.
  • 2王惠蔷,陈校华.10 kV电网中性点接地方式的分析[J].广东电力,2006,19(1):50-52. 被引量:9
  • 3李耀.电力安全知识[M].北京:水利电力出版社,1996.
  • 4R.维尔罕姆,M.华德斯著,吴维诚,王一宁译.高压输电系统的中性点接地[M].北京:中国工业出版社,1996.
  • 5李福寿.中性点非有效接地电网的运行[M].北京:水利水电出版社,2000.

二级参考文献1

  • 1DL/T620-1997.交流电气装置的过电压保护和绝缘配合[S].[S].,..