摘要
阐述了电源备自投的结构和工作原理,结合其在黑河电业局220 kV黑河变电所的所变系统中应用,来说明RCS9000系列装置的可靠性和自投方式。根据现场实际运行要求和装置功能,提出了改进方案。
The structure and principle of standby power self - put into use were discussed, and explored the reliability and self - put into use means of RCS9000 series devices by combining with its application to 220 kV system in Heihe substation. The scheme to improve was put forward according to the actual operation require- ments in field and its functions.
出处
《黑龙江电力》
CAS
2007年第2期121-123,共3页
Heilongjiang Electric Power
关键词
备用电源
闭锁
变电所
自动投入
standby power
lockout
substation
automatic operation