期刊文献+

分离式热管蒸发段传热特性的试验研究 被引量:1

EXPERIMENTAL STUDY ON HEAT TRANSFER CHARACTERISTICS OF SEPARATED TYPE HEAT PIPE EVAPORATION SECTION
在线阅读 下载PDF
导出
摘要 在研究分离式热管蒸发段流动特性的基础上,对其传热特性进行了试验研究,获得了一些重要的结论.文中着重分析了核态沸腾传热区及飞溅降膜传热区的传热原理;根据试验数据回归整理了相应的换热系数无量纲准则关系式,计算值与试验数据吻合相当好;分别与大空间池沸腾传热和整体式热虹吸管热管蒸发段降膜区传热进行了比较,其结果为分离式热管的研究及工程应用提供了理论的依据. Based on the investigation of flow characteristic in an evaporator of separate heat pipe,its heat transfer characteristics have been investigated,and some important conclusions have been obtained in this paper. The analysis is focused on the heat transfer mechanism of the nucleate boiling and splash downwards flow liquid film regions. And the empirical dimentionless correlations of heat transfer coefficient are obtained by the regression analysis. Both of them are well agreement with the experimental data,and the comparisons with the heat transfer coefficients of pool boiling and the downwards flow liquid film region in integral thermosyphon evaporator are made,respectively.The results will provide theoretical basis for investigation and engineering application of separate heat pipe.
机构地区 西安交通大学
出处 《西安交通大学学报》 EI CAS CSCD 北大核心 1996年第6期42-47,共6页 Journal of Xi'an Jiaotong University
关键词 传热特性 热管 沸腾传热 分离式 蒸发段 heat transfer characteristics heat pipe boiling heat transfer
  • 相关文献

参考文献4

  • 1徐国强,多相流与传热论文集,1989年
  • 2Xia Jilian,Proc of Int Symposium of Phase Change Heat Transfer,1988年
  • 3Chen Yuanguo,Proc of 6th Heat Pipe Symposium,1986年
  • 4杨世铭,传热学,1986年

同被引文献15

  • 1朱玉琴,李迓红.分离式热管小倾角蒸发段传热特性的试验研究[J].西安石油大学学报(自然科学版),2006,21(1):51-53. 被引量:7
  • 2Imura H, Saito Y, Katsumata Y. Flow and heat transfer characteristics in a two-phase loop thermosyphon [ J ]. Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers, 1988, 5 (2): 63-72.
  • 3Imura H, Takeshita K, Doi K. The effect of subcooling on the flow and heat transfer characteristics in a two-phase loop thermosyphon [J]. Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers, 1994, 11 (2): 209-218.
  • 4Rahmatollah K. Heat transfer in the evaporator of an advanced two-phase thermosyphon loop [J]. International Journal of Refrigeration, 2005, 28 (2) .. 190-202.
  • 5Chen Y G, Gao M, Xin M. Experiments of heat transfer performance of separate type thermosyphon//International Heat Pipe Conference [C]. Osaka, 1986.
  • 6MouKai(牟楷).Separate type heat pipe heat exchangerperformance [J].炼铁,1988,4:8-13.
  • 7Chen K, Chen Y, Tsai S. An experimental study of the heat transfer performance of a rectangular two-phase natural circulation loop [J]. Experimental Heat Transfer--An International Journal, 1990, 3 (1): 27-47.
  • 8Cooper M. Saturation nucleate pool boiling., a simple correlation//lst UK National Conference on Heat Transfer [C].UK, 1984.
  • 9Imura H, Kusuda H, Ogata J I. Heat transfer in two-phase closed-type thermosyphons [ J ]. JSME Transactions, 1979, 45:712-722.
  • 10Gungor K, Winterton R. Simplified general correlation for saturated flow boiling and comparisons of correlations with data [J]. Chemical Engineering Research By- Design, 1987, 65 (2): 148-156.