期刊文献+

上转磷光免疫层析检测肠出血性大肠杆菌O157 被引量:17

Development of UCP-immunochromatography Test for Rapid Detection of E.coli O157
在线阅读 下载PDF
导出
摘要 目的建立一种肠出血性大肠杆菌O157的上转磷光免疫层析快速检测方法。方法利用上转换磷光标记和双抗体夹心免疫层析技术检测大肠杆菌O157,评价了该法的敏感性和特异性,并用于模拟污染食品样品的检测。结果该法能在40min内完成检测,应用于不同的肠杆菌科细菌如其他大肠杆菌、沙门菌、志贺菌、变形杆菌、产气肠杆菌、枸橼酸杆菌、沙雷菌、耶尔森菌以及葡萄球菌、副溶血弧菌、单增李斯特菌等23种28株常见细菌,未发现有交叉反应,检测灵敏度为5×103CFU/ml,每次最低可检测500个细菌,对奶粉、咖啡粉、饼干、蛋糕、绿豆糕、果冻、燕窝、果汁等样品中的人工染菌均可检测,最低检测浓度为5×103CFU/ml。结论肠出血性大肠杆菌O157上转磷光免疫层析方法简便快速,特异性和灵敏性好,适用于现场的快速检测。 Objective To develop a method for rapid detection of Enterohemorrhagic E. coli O157 (EHEC O157) on the spot. Method An Up-Converting Phosphor (UCP) -immunoehromatography test (ICT) based on double-antibody sandwich assay was developed for detection of EHEC O157. The sensitivity and specificity of the method were evaluated. The feasibility of screening the bacteria in food samples were evaluated by different food samples artificially contaminated with EHEC O157 : H7, including milk, starch, coffee, biscuit, cake, juice, etc. Results Typical analysis time was less than 40 minutes per sample. The sensitivity of the test was 5 ×10^3 CFU/ml. No cross reaction was found when the method was used to detect other Enterobacteriaceae (including E. coli, Salmonella, Shigella, Proteus, Morganella, Citrobacter, Enterobacter, Serratia ), Staphylococus and V. parahemolyticus, confirming that the method is highly specific for E. coli O157. Conclusion The UCP- immunoehromatography test provides a rapid, specific and sensitive measure for detecting EHEC O157 on the spot.
出处 《中国食品卫生杂志》 2007年第1期41-44,共4页 Chinese Journal of Food Hygiene
基金 国家自然科学基金资助(30500455) 国家质量监督检验检疫总局重大科研专项资助(2005IK0143)
关键词 大肠杆菌0157 发光 上转换发光材料 免疫学技术 Eseherichia coli O157 Luminescence Up-Converting Phosphor Immunologic Techniques
  • 相关文献

参考文献6

  • 1周蕾,纪军,杨瑞馥.上转磷光技术在快速生物分析中的应用[J].生物技术通报,2003,19(3):20-25. 被引量:16
  • 2赵永凯,周蕾,黄惠杰,杨瑞馥,黄立华,任冰强,卢健,王向朝.基于上转换发光技术的生物传感器及其应用[J].光学学报,2005,25(6):841-847. 被引量:14
  • 3NIEDBALA R S,VAIL T L.Multiphoton up-converting phosphors for use in rapid immunoassays[J].SPIE,2000,3913:193-203.
  • 4ZANG JINGCUN,LIU YANXING.Progress of study on upconversion materials and its application on laser technology[J].High Technology Letters,1996,3:58-61.
  • 5NIEDBALA R S,FEINDT H,KARDOS K,et al.Detection of analytes by immunoassay using up-converting phosphor technology[J].Analytical Biochemistry,2001,293:22-30.
  • 6TAKEDA T,YAMAGATA K,YOUHIDA Y,et al.Evaluation of immunochromatography based rapid detection kit for fecal Escherichiacoli O157[J].Kansenshogaku Zasshi,1998,72(8):834-839.

二级参考文献22

  • 1黄惠杰,翟俊辉,赵永凯,杨瑞馥,任冰强,程兆谷,杜龙龙,路敦武.多探头光纤倏逝波生物传感器及其性能研究[J].中国激光,2004,31(6):718-722. 被引量:18
  • 2陈晓波,张光寅,宋增福.稀土化合物材料上转换发光与激光的研究与进展[J].光谱学与光谱分析,1995,15(3):1-6. 被引量:33
  • 3臧竞存,刘燕行.上转换材料研究进展及其在激光技术中的应用[J].高技术通讯,1996,6(3):58-61. 被引量:7
  • 4Paul Corstjens, Michel Zuiderwijk, Antoinette Brink, et al. Clinical Chemistry, 2001, 47(10) : 1885-- 1893.
  • 5Zijlmans H, Bonnet J, Burton J, et al. Analytical Biochemistry,1999, 267:30-36.
  • 6Kardos, et al. United States Patem: 6312914, 2001,293:22-30.
  • 7R Sam Niedbala, Hans Feindt, Keith Kardos, et al. Analytical Biochemistry , 2001, 293:22-30.
  • 8RS Niedbala, TL Vail, H Feindt, et al. In In-Vitro Diagnostic Instrumentation, Gerald E. Cohn, Editor, Proceedings of Spie ,2000, 3913:193-203.
  • 9Letter to The Editor. Journal of Colloid and Interlace Sciance ,1992, 150: 2594--2598.
  • 10Johannes Hampl, Michael Hall, Naheed A Mufti, et al. Analytical Biochmaistry , 2001, 288:176-187.

共引文献26

同被引文献226

引证文献17

二级引证文献86

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部