期刊文献+

氧化电位水对胃镜消毒效果的观察 被引量:3

Disinfectant effect of electrolyzed oxidizing water
在线阅读 下载PDF
导出
摘要 目的为寻找一种方便、安全、快速杀灭常见病原微生物的消毒方法,将氧化电位水用于临床胃镜消毒,观察其消毒效果。方法对临床污染的50支胃镜经去有机物处理后,以EOW生成机制备的EOW原液进行消毒后细菌培养,以及不同时间杀灭效果比较的试验。结果EOW对胃镜内、外表面自然菌杀灭率分别为99.06%、99.85%,对常见致病菌可达到100%的杀灭率。结论氧化电位水能有效杀灭常见微生物,而且用时短,无毒副反应,是一种高效、安全、方便的消毒剂。 Objective To search for a convenient safe and rapid method for disinfection of gastroscope in clinical use, electrolyzed oxidizing water(EOW) was ased.Methods After removing organic matter from 30 clinically used gastroscopes, aU the gastroscopes were disinfected With EOW , produced by an EOW generator. The sterilizing effect at different times was determined by bacterial culture. Results The sterilization raties in the exterior and interior surfaces of gastroscope were 99.06% and 99.85% ,respectively.The sterilization mile for common pathogenic bacteria reached 100%. Conclusions Electrolyzed oxidizing water can effectively kill common microorganisms. It is an efficient, safe and convenient disinfectant without toxic and side effects.
出处 《武警医学》 CAS 2006年第5期345-348,共4页 Medical Journal of the Chinese People's Armed Police Force
关键词 氧化电位水 胃镜消毒 细菌培养 Electrolyzed oxidizing water Gastroscope disinfection Bacterial cahure
  • 相关文献

参考文献9

二级参考文献37

  • 1李新武,袁洽,孙守宏.在乙型肝炎表面抗原破坏试验中对ELISA法检验结果影响因素的研究[J].中国消毒学杂志,1995,12(2):89-93. 被引量:8
  • 2念国仁,李闽真,陈金秋,林立旺,王碧桑.五种含氯复方消毒剂杀菌效果与稳定性的比较[J].中国消毒学杂志,1995,12(4):206-208. 被引量:6
  • 3李新武,孙守宏,李涛,李晓青,李秋丽,袁洽劻.酸化电位水对微生物的杀灭效果及其作用机理的初步研究[J].中华流行病学杂志,1996,17(2):95-98. 被引量:120
  • 4魏兰芬,许激,林军明.含氯消毒剂对芽胞和HBsAg有效作用浓度检测[J].中国卫生检验杂志,1996,6(3):162-164. 被引量:10
  • 5Fegley,JB. Properties and composition of the terrestrial ocean and of the atmospHeres of the earth and other planets,in Global Earth PHysics by Ahrens T.J[M].Am:GeopHys Union,1995;320-345.
  • 6Voet,D and Voet JG.Biochemistry [M]. 2nd ed. New York: John Wiley & Sons. Lne. 1995:1361.
  • 7Kim C, Hung YC, Brackett RE. Roles of oxidation-reduction potential in electrolyzed oxidizing and chemically modified water for the inactivation of food-related pathogens [J]. J Food Prot .2000 ;63(1):19.
  • 8Len SV, Hung YC, Erichson M,et al.Ultraviolet spectrophotometric characterization and bactericidal properties of electrolyzed oxidizing water as influenced by amperage and pH [J]. J Food Prot, 2000;63(11):1534.
  • 9Kim C, Hung YC, Brackett RE. Roles of oxidation-reduction potential in electrolyzed oxidizing and chemically modified water for the inactivation of food-related pathogens [J]. J Food Prot, 2000; 63 (1):19.
  • 10Kiura H, Sano K. Bactericidal activity of electrolyzed acid water from solution containing sodium chloride at low concentration, in comparison with that at high concentration [J]. J Microbiological Methods, 2002;49(3):285.