期刊文献+

微波消解-紫外分光光度法测定水中总氮 被引量:18

Determination of Total Nitrogen in Water by Microwave Digestion UV Spectrophotometry
在线阅读 下载PDF
导出
摘要 研究了用微波消解-紫外分光光度法测定水样中的总氮,结果表明,所提出的消解方法具有操作简单、省时、消解完全的特点,精密度和准确度均令人满意.方法的线性范吲为0.0242~9.60mg/L,水样加标回收率为101%~103%,相对标准偏差为0.13%~0.44%。 The microwave digestion- UV spectrophotometric method for the determination of total nitrogen in water has been studied. Compared with traditional digestion method, the proposed digestion method has the advantages of easier operation, time saving and high efficiency. The precision and accuracy were satisfactory. The linear range of the method was 0. 024 2 - 9. 60 mg/L, and the recovery of spiking standard nitrogen was 101% - 103% . The relative standard deviation was less than 0. 44%.
作者 张丰如 何江
机构地区 嘉应学院化学系
出处 《分析测试学报》 CAS CSCD 北大核心 2006年第3期112-114,共3页 Journal of Instrumental Analysis
关键词 总氮 过氧化氢-微波消解 紫外分光光度法 Total nitrogen Hydrogen peroxide - microwave digestion U V spectrophotometry
  • 相关文献

参考文献6

二级参考文献4

  • 1高岐,范彩玲,魏建河.微波加热快速测定总糖量的研究[J].分析化学,1994,22(4):418-418. 被引量:15
  • 2标准出版社第二编辑室.环境保护国家标准汇编[M].北京:中国标准出版社,1995.228.
  • 3国家环保局,水和废水监测分析方法(第3版),1989年,278页
  • 4中国环境监测总站,环境水质监测质量保证手册,1984年,231页

共引文献90

同被引文献1109

引证文献18

二级引证文献83

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部