GIS局部放电超高频检测法有关问题的仿真研究 被引量:37

Research on Ultra-High-Frequency Method for Detection of Partial Discharge in GIS
在线阅读 下载PDF
导出
摘要 气体绝缘组合电器(gas insulated switchgear,GIS)中的局部放电在腔体中产生超高频(ultra high frequency,UHF)电磁波信号。为研究GIS局部放电源与UHF信号的关系,利用时域有限差分法计算局部放电产生的UHF信号;通过改变放电源和探头的参数,研究了局部放电产生的UHF信号的特性。仿真分析结果表明:UHF信号的幅值与局部放电脉冲幅值成线性关系;UHF信号与放电源的径向位置、放电通道长度、放电脉冲波形以及放电源与探头的夹角有关。单纯 UHF信号很难解释局部放电量的大小,但UHF信号可在一定程度上反映出GIS的绝缘状态。 In gas insulated switchgear (GIS) the partial discharge (PD) causes ultra high frequency (UHF) electromagnetic wave signals within the switchgear body. To research the relation between the PD source and UHF signals, the PD caused UHF signals are calculated by finite difference method in time domain; by means of changing the parameters of PD source and sensors, the characteristics of UHF signals caused by PD are researched. Simulation results show that the amplitudes of UHF signals are in linear relation to those of PD pulses; the UHF signals relate to following factors: radial position of PD source, length of discharging channel, waveform of discharging pulse and the included angle between the PD source and sensor. It is hard to explain the discharge quantity merely by UHF signals, however the UHF signals can reflect the insulation situation within the GIS to a certain extent.
出处 《电网技术》 EI CSCD 北大核心 2006年第7期37-40,63,共5页 Power System Technology
关键词 气体绝缘组合电器 局部放电 超高频法 时域有限差分法 高电压绝缘技术 gas insulated switchgear partial discharge ultra high frequency method finite-difference time-domain high voltage insulation technology
  • 相关文献

参考文献15

二级参考文献64

  • 1谢尔.札曼,朱德恒,金显贺,谈克雄.局部放电在线监测中的自适应数字滤波系统[J].高电压技术,1994,20(3):33-37. 被引量:17
  • 2董旭柱,王昌长,朱德恒.电力变压器局部放电在线监测研究的现状和趋势(二)[J].变压器,1996,33(5):2-7. 被引量:24
  • 3胡广书.数字信号处理--理论、算法与实现[M].北京:清华大学出版社,1998..
  • 4林立生,林杨.高压SF_6断路器综述[J].华北电力技术,1997(5):45-49. 被引量:8
  • 5Salama M M A, Bartnikas R. Determination of neural-network topology for partial discharge pulse pattern recognition[J]. IEEE Trans on Neural Networks, 2002, 13(2): 446-456.
  • 6Meijer S, Gulski E, Smit J J. Pattern analysis of partial discharges in SF6 GIS[J]. IEEE Trans on Dielectrics and Electrical Insulation,1998, 5(6): 830-842.
  • 7Hoshino T, Nojima K, Hanai M. Real-time PD identification in diagnosis of GIS using symmetric and asymmetric UHF sensors[A]. IEEE/PES Transmission and Distribution Conference and Exhibition[C], Yokahama, 2002: 798-801.
  • 8Kawada M. Fundamental study on location of a partial discharge source with a VHF-UHF radio interferometer system[J]. Electrical Engineering in Japan, 2003, 144(1): 32-41.
  • 9Neuhold S M, Schmatz M L, Hassig Metal. Combined broad and narrow band multichannel PD measurement system with high sensitivity for GIS[A]. IEE International Symposium on 'High Voltage Engineering'(ISH99) [C], London, 1999, 5(467): 5-152.
  • 10Pryor B M. A review of partial discharge monitoring in gas insulated substations[A]. IEE Colloquium Partial Discharges in Gas Insulated Substations[C], London, 1994: 1-2.

共引文献509

同被引文献398

引证文献37

二级引证文献550

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部