电感耦合等离子体发射光谱法测定纯银中的杂质元素 被引量:14

Determination of impurity elements in pure silver with inductiv ely-coupled plasma spectrometer
在线阅读 下载PDF
导出
摘要 研究并建立了纯银样品经硝酸溶解,标准基体匹配,直接用电感耦合等离子体发射光谱测定纯银中铜、铁、铅、锑、铋、钯、硒、碲、锌杂质元素的方法.其检出限分别为0.003 9,0.003 3,0.015,0.015,0.007 3,0.024,0.008 0,0.004 2,0.003 0μg/ml;回收率均在97.2%~102.5%之间;相对标准偏差为0.76%~5.02%. After the silver samples were resolved in nitric acid and matched with standard matrix, the copper, ferrum,plumbum, stibium, bismuth,palladium, selenium, tellurium and zinc contained in the samples with inductively-coupled plasma spectrometer. The DL of the impurity elements are 0.003 9,0.003 3,0.015,0.015,0.007 3,0.024,0.008 0,0.004 2,0. 003 0μg/ml respectively, the reclamation rates are with in the range of 97. 2 % - 102.5 %, and the RSD are in the range of 0.76% - 5.02%.
机构地区 长春黄金研究院
出处 《黄金》 CAS 北大核心 2005年第8期41-43,共3页 Gold
关键词 纯银 杂质元素 电感耦合等离子体发射光谱 pure silver impurity element inductively-coupled plasma spectrometer
  • 相关文献

参考文献2

二级参考文献6

  • 1符斌.ICP光谱分析指南[M].北京:冶金工业出版社,1991.40.
  • 2冯忠 安建伟 等.高频感应耦合等离子光谱法测定银铜系列合金中的Pb、Sb、Fe杂质元素[J].分析试验室,1985,7(4):39-30.
  • 3吴学汉 等.感光科学与光化学,1995,(4):71-71.
  • 4中华人民共和国国家标准汇编.银化学分析方法.GB/T 11067—1989,1990年
  • 5陈新坤,电感耦合等离子体光谱法原理及应用,1987年,10页
  • 6冯忠,分析试验室,1985年,7卷,4期,29页