摘要 研究了荧光谱线分布对共焦荧光显微镜中分辨率的影响,导出了荧光谱线分布的荧光功率传输函数、三维脉冲响应函数.数值计算了荧光谱线均匀分布的情况,结果表明与采用单一中心荧光波长的分辨率比较,共焦荧光显微镜的横向分辨率、纵向分辨率随着荧光谱线范围和色散的增大而下降;谱线响应范围小的探测器有利于分辨率. The dependence of the resolution of a fluorescent confocal microscopy on fluorescent spectrum is studied, and the power transfer function and three-dimensional pulse spread function are derived. Assuming well-distributed fluorescent spectrum, calculated results show that the lateral resolution and the Axial resolution are worse while fluorescent spectrum widen and dispersion coefficient increased, compared with that by only using the central fluorescent wavelength. The detector responding to narrower fluorescent spectrum is good for the resolution.
出处 《光子学报》 EI CAS CSCD 北大核心 2005年第6期931-934,共4页 Acta Photonica Sinica
基金 广东省自然科学基金(010207) 华南农业大学校长基金资助项目
关键词 共焦荧光显微镜 荧光谱线分布 分辨率 Fluorescent confocal microscopy Fluorescent spectrum Resolution
  • 相关文献

参考文献10

二级参考文献46

  • 1张平,吴震,王翠英,向际鹰.荧光共焦扫描系统成像特性的优化[J].光学学报,1997,17(3):308-313. 被引量:10
  • 2Martlnez-Comd M, Andr6s P, Ojeda-Castafieda J, et al.Tunable axial superresolution by annular binary filters.Application to confocal microscopy. Opt Comm, 1995,119(5/6) :491 -498.
  • 3Sales T B M, Morris G M. Axial superresolution with phaseonly pupil filters. Opt Comm, 1998,156(5/6) :227 -230.
  • 4Hegedus Z S, Sarafism V. Superresolving filters in confocally scanned imaging systems. J Opt Soc Am ( A ),1986,3( 11 ) :1892 - 1896.
  • 5Marttnez-Corral M, Pons A, C.abaHero M T. Axial apodization in 4pi-confocal microscopy by annular binary filters. J Opt Soc Am(A), 2002, 19(8) :1532 - 1536.
  • 6Boyer G. New class of axially apodizing filters for confocal scanning microscopy. J Opt Soc Am(A), 2002,19(3) :584- 589.
  • 7sales T R M, Morris G M. Diffractive superresolution elements. J Opt Soc Am(A) ,1997,14(7) :1637 - 1646.
  • 8Neil M A A, JuAkaitis B, Wilson T, et al. Optlmized pupil-plane filters for confocal microscope point spread function engineering. Opt Leg, 2000,25(4) :245 - 247.
  • 9Gu M, Tannous T, Sheppard J Pt. Effect of an annular pupil on cofocal imaging through highly scattering media. Opt Lett, 1996,21(5) :312 -314.
  • 10Cox I J, Sheppard C J R, Wilson T. Reappraisal of arrays of concentric annuli as superresolving filters.J Opt Soc Am,1982,72(9) :1287 - 1291.

共引文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部