摘要 介绍了地源热泵的特性及其发展前景,分析了现有传热模型的局限性。在V.C.Mei传热模型的基础上,结合系统能量方程和热传导方程建立了套管式换热器的传热模型。采用有限元法和有限差分法对埋管周围的温度场进行了数值计算。通过与实测值的对比表明该传热模型能更好地反映出真实的传热过程和传热机理。 Presents the characteristics and prospects of ground-source heat pumps and analyses the limitation of existed heat transfer models. Based on the V. C. Mei model,together with the energy conservation equation and heat transfer equation,establishes the heat transfer model of double-pipe heat exchangers. Numerically calculates the temperature field around buried pipes using the finite element method and finite difference method. It is found that the heat transfer model accords with the real heat transfer process and mechanism better by comparing the calculating results with the test data.
机构地区 浙江大学
出处 《暖通空调》 北大核心 2005年第6期16-19,共4页 Heating Ventilating & Air Conditioning
  • 相关文献

参考文献7

二级参考文献9

  • 1周学圣 张九思.数学物理方法[M].山东科学技术出版社,..
  • 2曾淼.地源热泵地下换热器换热计算模拟与实验研究.重庆建筑大学研究生论文[M].,1998,12..
  • 3[1]LESSEM L B, et al. A method of calculating the distribution of temperature in flowing gas wells[J]. Trans., AIME, 1957, 2(10): 169-172.
  • 4[2]MOSS J T, et al. How to calculate temperature profiles in a water injection well[J]. Oil & Gas J., 1959, 57(11): 174-178.
  • 5[3]RAMEY H J JR. Wellbore heat transmission[J]. JPT, 1962, 14(4): 427-435.
  • 6[4]BARELLI A and PALAMA A. A new method for evaluation formation equilibrium temperature in holes during drilling[J].Geothermics, 1981, 14(4): 95-102.
  • 7[5]WOOLEY G R. Computing downhole temperatures in circulation, injection, and production wells[J]. JPT, 1980, 32(12): 1509-1522.
  • 8[6]STEHFEST H. Numerical inversion of Laplace transforms[J].ACM, Communications, 1970, 13(1):47-49.
  • 9王勇,付祥钊.地源热泵的套管式地下换热器研究[J].重庆建筑大学学报,1997,19(5):13-17. 被引量:40