摘要
堆内试验回路的安全性现在越来越受到有关核安全部门的重视。它的可靠性不仅影响试验回路本身的安全,而且还有可能影响反应堆系统的安全。从系统压力来说,堆内试验回路基本上可分为高压和低压两种。本文笔者用RELAPS/MOD2系统分析程序对堆内高压试验回路进行了一些典型事故分析。分析结果表明其设计符合相应的验收准则。
The department of nuclear safety emphasize increasingly the importmence of the safety forin-pile test loops. The reliabilities of test loops affect not only loops safety, but also the relevant nuclear reactor systems. From the view of system pressure, the in-pile test loops can bedivided into tow kinds: high pressure and low pressure test loops. Some accidence safety analyses for the high pressure test loop have been performed by using RELAP5/MOD2. The results of analyses show that the designs of the test loop meet corresponding acceptance criteria.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1994年第5期436-439,共4页
Nuclear Power Engineering
关键词
堆内试验回路
辐射防护
系统分析
Nuclear safety In-pile test loop System analysis codes SB-LOCA