期刊文献+

小电流接地系统接地检测的工程应用分析 被引量:4

Analysis of fault line selection for power system with indirectly grounded neutral
在线阅读 下载PDF
导出
摘要 针对目前小电流接地系统的接地选线装置现场选线的准确性差、投入率不高的问题,根据系统的特点对问题进行了工程应用上的分析,经过对小电流接地系统的理论分析、选线设备原理、采样误差等方面对问题进行剖析,提出了减小综合测量误差,提高选线准确性、可靠性的措施。 As to on-site fault line selection of power system with indirectly grounded neutral, its accuracy and application results are not satisfactory. Aiming at that problem and based on the characteristics of the system, the paper analyses the problems from the perspective of engineering application, and puts forward measures with which the errors can be reduced, and correctness and reliability of fault line selection can be improved.
机构地区 唐山供电设计院
出处 《继电器》 CSCD 北大核心 2004年第7期21-23,共3页 Relay
关键词 小电流接地系统 接地选线 零序电流互感器 误差 power system with indirectly grounded neutral fault line selection zero-sequence current transformer error
  • 相关文献

参考文献3

  • 1范锡普(FAN Xi-pu).发电厂电气部分(Electric Part of Power Plant)[M].北京:水利电力出版社(Beijing:Hydraulic and Electric Power Press),1987.
  • 2牟龙华.零序电流有功分量方向接地选线保护原理[J].电网技术,1999,23(9):60-62. 被引量:126
  • 3能源部西北电力设计院(Northwest Power Design Institute).电力工程电气设计手册(电气二次部分)(Manual for Design of Electric Power Project,Electric Secondary Part)[M].北京:中国电力出版社(Beijing:China Electric Power Press),1991.

二级参考文献9

共引文献125

同被引文献23

引证文献4

二级引证文献15