期刊文献+

Correlation of pattern reversal visual evoked potential parameters with the pattern standard deviation in primary open angle glaucoma 被引量:3

Correlation of pattern reversal visual evoked potential parameters with the pattern standard deviation in primary open angle glaucoma
在线阅读 下载PDF
导出
摘要 AIM:To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation(PSD)of Humphrey visual field could be associated with visual evoked potential(VEP)parameters of patients having primary open angle glaucoma(POAG).METHODS:Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential(PRVEP)were assessed in 100 patients with POAG.The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated(full field)and displayed on VEP monitor(colour 14')by an electronic pattern regenerator inbuilt in an evoked potential recorder(RMS EMG EP MARK II).RESULTS:The results of our study indicate that there is a highly significant(P【0.001)negative correlation of P100 amplitude and a statistically significant(P【0.05)positive correlation of N70 latency,P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student’s t-test.CONCLUSION:Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values.Conversely,as PSD increases the magnitude of VEP excursions were found to be diminished. AIM:To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation(PSD)of Humphrey visual field could be associated with visual evoked potential(VEP)parameters of patients having primary open angle glaucoma(POAG).METHODS:Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential(PRVEP)were assessed in 100 patients with POAG.The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated(full field)and displayed on VEP monitor(colour 14')by an electronic pattern regenerator inbuilt in an evoked potential recorder(RMS EMG EP MARK II).RESULTS:The results of our study indicate that there is a highly significant(P<0.001)negative correlation of P100 amplitude and a statistically significant(P<0.05)positive correlation of N70 latency,P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student’s t-test.CONCLUSION:Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values.Conversely,as PSD increases the magnitude of VEP excursions were found to be diminished.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期326-329,共4页 国际眼科杂志(英文版)
关键词 pattern reversal pattern standard deviation visual field P100 latency pattern reversal, pattern standard deviation, visual field, P100 latency
  • 相关文献

同被引文献21

引证文献3

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部