全污水处理厂数学模拟的BioWin模型 被引量:9

BioWin model for whole wastewater treatment plant process modeling
在线阅读 下载PDF
导出
摘要 目前污水处理厂的数学模拟已经朝全污水处理厂模拟的方向发展,着眼于污水处理厂整体的优化设计和运行。随着厌氧消化模型和旁流工艺模型的开发,建立包括一个污水处理厂水区和泥区以及旁流处理工艺在内的全厂污水处理工艺模拟已经成为可能。全污水处理厂数学模拟将是污水处理厂节能减排方案分析和评价的重要工具。全面介绍了全污水处理厂模拟的BioWin模型,主要包括活性污泥模型、厌氧消化模型和旁流处理工艺模型,并将此模型与现行其他常用模型进行对比。 BioWin mathematical model,implemented in BioWin simulator,is developed for modeling whole wastewater treatment processes(e.g.activated sludge,anaerobic digestion and sidestream processes).whole wastewater treatment process modeling makes it possible to completely analyze wastewater treatment plants for optimal design and operation purposes.BioWin model has been widely and successfully used in practice.This paper presents key features and major components of BioWin model.
出处 《给水排水》 CSCD 北大核心 2008年第S1期159-166,共8页 Water & Wastewater Engineering
关键词 活性污泥模型 全污水处理厂数学模拟 BioWin数学模型 优化设计 节能减排 Activated sludge model Whole plant process modeling BioWin model Optimization Cost savings
  • 相关文献

参考文献1

二级参考文献13

  • 1Henze M, Gujer W, Mino T,et al. Activated sludge model No. 2D[J]. Water Sci Technol,1999,39( 1 ) : 165 - 182.
  • 2Barker P S, Dold P L. General model for biological nutrient removal activated sludge systems:model presentation [ J ]. Water Environ Res, 1997,69 (5) : 969 - 984.
  • 3Hu Z, Wentzel M C, Ekama G A. A general model for biological nutrient removal activated sludge systems: model development [ J ]. Biotechnol Bioeng, 2007, 98 (6) :1242 - 1258.
  • 4Dold P L, Fairlamb P M,Jones R,et al. Sidestream modelling incorporated into whole plant simulation [ A ]. Closing the Nitrogen Cycle from Urban Landfill Leachate by Biological Nutrient Removal over Nitrate and Thermal Treatment [ C ]. Spain : Clonic project,2007.
  • 5Wilson A W, Dold P L. Using a process simulator for design, analysis, de-bottlenecking and operation of wastewater treatment plants[A]. Presented at the 50th Annual Conference of the Western Canada Water & Wastewater Association [ C ]. Canada : Water & Wastewater Association, 1998.
  • 6Vanrolleghem P A, Rosen C,Zaher U, et al. Continuitybased interfacing of models for wastewater systems described by petersen matrices[J]. Water Sci Technol, 2005,52( 1 -2) :493 -500.
  • 7Volcke E I P,van Loosdrecht M C M, Vanrolleghem P A. Continuity-based model interfacing for plant-wide simulation : a general approach [ J ]. Water Res,2006,40 ( 15 ) : 2817 - 2828.
  • 8Takacs I,Bye C M, Chapman K, et al. A biofilm model for engineering design [ J ]. Water Sci Technol, 2007,55 (8 -9) :329 -336.
  • 9Dold P L,Jones R M,Takacs I,et al. Practical guidance for WWTP model calibration and associated data gathering requirements [ A ]. Proceedings of the Water Environment Federation 76th Annual Technical Exhibition & Conference [ C ]. California : Water Environment Federation ,2003.
  • 10Melcer H, Dold P L, Jones R M, et al. Methods for Wastewater Characterization in Activated Sludge Modeling [ M ]. Alexandria, VA : Water Environment Research Foundation, 2004.