期刊文献+

空心加压螺钉治疗股骨颈骨折的轴向拔出实验研究 被引量:6

Axial pullout tests of cannulated cancellous screws used for femoral neck fracture
在线阅读 下载PDF
导出
摘要 目的通过实验,研究影响空心钉在股骨头内稳定性的重要因素,为临床中空心钉治疗股骨颈骨折选择理想的手术方案提供理论依据。方法31枚股骨头标本,空心螺钉按照治疗股骨颈骨折的方法植入股骨头。记录年龄、测量股骨头直径、测量股骨头骨密度、测量钉尖到关节面软骨的距离;同时固定股骨头和螺钉帽,通过实验机进行空心钉轴向拔出实验,记录最大拔出负荷。用SPSS11.5软件包对实验数据进行多元逐步回归分析。结果股骨头骨密度和钉尖到关节面软骨的距离与最大拔出负荷相关,前者呈正相关(P=0.002),而后者呈负相关(P=0)。钉尖到关节面大于8mm组和小于8mm组的最大拔出负荷之间有显著差异(P=0.004)。结论股骨头骨密度越高,一定范围内螺钉植入越深,越有利于内固定的稳定。 Objective The purpose of this experimental study was to find the important factors affecting the stability of cannulated cancellous screws in femoral head and provide experimental basis in clinical use on femoral neck fracture using internal fixation with cannulated cancellous screws.Methods 31 femoral heads were from the patients of femoral neck fracture,then cannulated cancellous screws were embedded into them by the method for the treatment of femoral neck fracture.We recorded the ages of the patients,th...
作者 王立 沈惠良
出处 《医用生物力学》 EI CAS CSCD 2008年第5期376-380,共5页 Journal of Medical Biomechanics
关键词 股骨颈骨折 空心加压螺钉 拔出实验 Femoral neck fracture Cannulated cancellous screws Pullout test
  • 相关文献

参考文献9

二级参考文献35

  • 1危杰,翟桂华,荣国威,李锦涛,王文庆,王满宜,高波.AO中空加压螺丝钉在股骨颈骨折治疗中的应用[J].中华创伤杂志,1994,10(2):82-83. 被引量:43
  • 2周维江.股骨转子间外翻截骨治疗股骨颈骨折不愈合[J].中华骨科杂志,1994,14(3):142-146. 被引量:9
  • 3童元,朱六龙,承长胜,志宏.经皮多根斯氏针固定股骨颈骨折若干问题[J].中国矫形外科杂志,1996,3(2):86-87. 被引量:10
  • 4戴克戎 愈昌泰.股骨距的解剖研究及其临床意义[J].中华骨科杂志,1983,3(3):111-111.
  • 5胥少汀 张健民 等.斯氏针内固定治疗股骨颈骨折的实验研究与临床应用[J].中华外科杂志,1986,24(8):471-471.
  • 6杨桂通.医用生物力学(第一版)[M].北京:科学出版社,1983.106-107.
  • 7耿硕儒 李毅 等.股骨距的解剖、X线、 力学及其临床意义研究[J].中国医学科学院学报,1988,10:340-342.
  • 8Husby T, Alho A, et al, Strength of femoral neck fracture fixation. Comparion of six techniques in cadavers. Acta Orthop Scand, 1987, dec, 58(6):634-637
  • 9Sjostedt A, Zetterberg C, Hansson T, et al. Bone mineral content and fixation strength of femoral neck fractures. Acta Orthop Scand, 1994, 65(2): (61 - 165)
  • 10Springer ER, Lachiewica PF, GilboreJA. Internal fixation of femoral neck fracture. A comparative biomechanical study of knowls Pins and 6.5mm cancellous screws. Clinical Orthopedics 1991,267: 85 - 92

共引文献416

同被引文献48

  • 1刘达,雷伟,吴子祥,杨彬奎,张伟.钉道局部点状固化技术强化椎弓根螺钉固定的生物力学研究[J].医用生物力学,2008,23(4):306-310. 被引量:2
  • 2胡丹,范卫民.不同布局空心螺钉治疗股骨颈骨折的生物力学差异[J].江苏医药,2005,31(9):646-648. 被引量:24
  • 3Mohammad Farooq Butt, Shablr A. Dhar, Naseem ul Gani,et al. Delayed fixation of displaced femoral neck fractures in younger adults[J]. Injury,2007,2008(39):238-243.
  • 4Bhandari M,Tornetta P 3rd, Hanson B, et al. Optimal internal fixation for femoral neck fractures: multiple screws or sliding hip screws? [J]. J Orthop Trauma,2009,23(6) :403-407.
  • 5H. R. McCarroll. Has a solution for the unsolved fracture been found? Problems and complications of fractures of femoral neck [J]. The Journal of the American Medical Association, 1953, 153(6) :536-540.
  • 6Cho MR,Lee SW,Shin DK,Kim SK,et al. A predictive method for subsequent avascular necrosis of the femoral head (AVNFH) by observation of bleeding from the eannulated screw used for fixation of intracapsular femoral neck fractures[J]. J Orthop Trauma, 2007,21(3) : 158-164.
  • 7Zlowodzki M, Weening B, Petrisor B, et al. The value of washers in cannulated screw fixation of femoral neck fractures [J]. J Trauma, 2005, 59(4) : 969-975.
  • 8Palm H, Gosvig K, Krasheninnikoff M, et al. A new meas- urement for posterior tilt predicts reoperation in undisplaced femoral neck fractures [ J ]. Acta Orthop, 2009, 80 ( 3 ) : 303 -307.
  • 9Bryan R, Nair PB, Taylor M. Use of a statistical model of the whole femur in a large scale, multi-model study of fem- oral neck fracture risk [ J ]. J Biomech, 2009, 42. ( 13 ) : 2171-2176.
  • 10Watanabe Y, Shiba N, Matsuo S, et al Biomechanical study of the resurfacing hip arthroplasty: Finite element a- nalysis of the femoral component [ J ]. J Arthroplasty, 2000, 15(4) : 505-511.

引证文献6

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部