In order to obtain the transient characteristics of a low-speed centrifugal pump during the start-up and shutdown stages,dedicated experimental tests were conducted with eight different valve opening conditions.The Pe...In order to obtain the transient characteristics of a low-speed centrifugal pump during the start-up and shutdown stages,dedicated experimental tests were conducted with eight different valve opening conditions.The Pearson correlation coefficient was used to reveal the linear correlation between variables.According to the results,the stable rotational speed decreases with increasing valve opening(rotational speed decreases from approximately 1472 to 1453 r/min),while the stable shaft power exhibits an increasing trend(shaft power increases from approximately 0.242 to 0.390 kW).The stable time and zeroing time of each parameter during start-up and shutdown processes vary,with the flow zeroing time significantly increasing with the relative flow,reaching up to 10.468 s,while the shaft power zeroing time is roughly between 1.219 and 1.375 s.The results demonstrate that with increasing valve opening,the stable and zeroing time of flow significantly increase(|r|greater than 0.95),while the stable and zeroing time of rotational speed,power,and head display a smaller sensitivity on the valve opening(|r|less than 0.6).展开更多
Centrifugal pumps are widely used in the metallurgy,coal,and building sectors.In order to study the hydraulic characteristics of a closed impeller centrifugal pump during its shutdown in the so-called power frequency ...Centrifugal pumps are widely used in the metallurgy,coal,and building sectors.In order to study the hydraulic characteristics of a closed impeller centrifugal pump during its shutdown in the so-called power frequency and frequency conversion modes,experiments were carried to determine the characteristic evolution of parameters such as speed,inlet and outlet pressure,head,flow rate and shaft power.A quasi-steady-state method was also used to further investigate these transient behaviors.The results show that,compared to the power frequency input,the performance parameter curves for the frequency conversion input are less volatile and smoother.The characteristic time is longer and the response to shutdown is slower.The quasi-steady-state theoretical head-flow curves match the experimental head-flow curves more closely at low flow rates when the frequency conversion input is considered.Moreover,in this case,the similarity law predicts the hydraulic performance more accurately.展开更多
基金supported by Science and Technology Project of Quzhou(Grant Nos.2023K256,2023NC08)Zhejiang Provincial Natural Science Foundation of China(Grant No.LZY21E050001)Hunan Province Key Field R&D Plan Project(Grant No.2022GK2068).
文摘In order to obtain the transient characteristics of a low-speed centrifugal pump during the start-up and shutdown stages,dedicated experimental tests were conducted with eight different valve opening conditions.The Pearson correlation coefficient was used to reveal the linear correlation between variables.According to the results,the stable rotational speed decreases with increasing valve opening(rotational speed decreases from approximately 1472 to 1453 r/min),while the stable shaft power exhibits an increasing trend(shaft power increases from approximately 0.242 to 0.390 kW).The stable time and zeroing time of each parameter during start-up and shutdown processes vary,with the flow zeroing time significantly increasing with the relative flow,reaching up to 10.468 s,while the shaft power zeroing time is roughly between 1.219 and 1.375 s.The results demonstrate that with increasing valve opening,the stable and zeroing time of flow significantly increase(|r|greater than 0.95),while the stable and zeroing time of rotational speed,power,and head display a smaller sensitivity on the valve opening(|r|less than 0.6).
基金supported by the“Pioneer”and“Leading Goose”R&D Program of Zhejiang(Grant No.2022C03170)Science and Technology Project of Quzhou(Grant No.2022K98)Hunan Province Key Field R&D Plan Project(Grant No.2022GK2068).
文摘Centrifugal pumps are widely used in the metallurgy,coal,and building sectors.In order to study the hydraulic characteristics of a closed impeller centrifugal pump during its shutdown in the so-called power frequency and frequency conversion modes,experiments were carried to determine the characteristic evolution of parameters such as speed,inlet and outlet pressure,head,flow rate and shaft power.A quasi-steady-state method was also used to further investigate these transient behaviors.The results show that,compared to the power frequency input,the performance parameter curves for the frequency conversion input are less volatile and smoother.The characteristic time is longer and the response to shutdown is slower.The quasi-steady-state theoretical head-flow curves match the experimental head-flow curves more closely at low flow rates when the frequency conversion input is considered.Moreover,in this case,the similarity law predicts the hydraulic performance more accurately.