The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off acco...The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off according to the number of the segments. This study evaluates the dose linearity and profile flatness/symmetry under low MU settings for Vero4DRT, a new linear-accelerator based irradiation system that currently implements step-and-shoot IMRT. To evaluate the dose linearity and flatness/symmetry, the point doses and beam profiles were measured as functions of MU and dose rates. The accuracy of dose delivery depended on the dose rate. Under all dose rates, the dose was linear within 1% above 5 MU and within 2% above 3 MU. The beam symmetry was degraded in-line compared with crossline, although both profiles were symmetric within 2% at all dose settings. The profile flatness was also within 2% above 5 MU at any dose rate and showed no significant variation among the low MU settings. To ensure stable beam delivery without increasing the treatment time of Vero4DRT, we recommend a delivery of 5 MU per segment at a dose rate of 500 MU/min.展开更多
We present the results of measurements made using the Vero4DRT radiation therapy system, which is not yet widely used, to assist technicians in achieving reliable and safe radiotherapy to the patient. We measured perc...We present the results of measurements made using the Vero4DRT radiation therapy system, which is not yet widely used, to assist technicians in achieving reliable and safe radiotherapy to the patient. We measured percent depth dose, beam profile, and relative scatter factor under water and air conditions. The Vero4DRT system has a 150 × 150-mm fixed secondary collimator. Its multileaf collimator (MLC) design is a single-focus type, with 30 pairs of 5 mm thick leaves at the isocenter, and produces a maximum field size of 150 × 150 mm. Profile measurements were performed using a 0.016-cm<sup>3</sup> ionization chamber (PTW31016 pinpoint chamber;PTW, Freiburg GmbH Germany). A brass build-up cap was used for measurements obtained in air conditions. We present a useful measurement dataset for users of the Vero4DRT system.展开更多
文摘The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off according to the number of the segments. This study evaluates the dose linearity and profile flatness/symmetry under low MU settings for Vero4DRT, a new linear-accelerator based irradiation system that currently implements step-and-shoot IMRT. To evaluate the dose linearity and flatness/symmetry, the point doses and beam profiles were measured as functions of MU and dose rates. The accuracy of dose delivery depended on the dose rate. Under all dose rates, the dose was linear within 1% above 5 MU and within 2% above 3 MU. The beam symmetry was degraded in-line compared with crossline, although both profiles were symmetric within 2% at all dose settings. The profile flatness was also within 2% above 5 MU at any dose rate and showed no significant variation among the low MU settings. To ensure stable beam delivery without increasing the treatment time of Vero4DRT, we recommend a delivery of 5 MU per segment at a dose rate of 500 MU/min.
文摘We present the results of measurements made using the Vero4DRT radiation therapy system, which is not yet widely used, to assist technicians in achieving reliable and safe radiotherapy to the patient. We measured percent depth dose, beam profile, and relative scatter factor under water and air conditions. The Vero4DRT system has a 150 × 150-mm fixed secondary collimator. Its multileaf collimator (MLC) design is a single-focus type, with 30 pairs of 5 mm thick leaves at the isocenter, and produces a maximum field size of 150 × 150 mm. Profile measurements were performed using a 0.016-cm<sup>3</sup> ionization chamber (PTW31016 pinpoint chamber;PTW, Freiburg GmbH Germany). A brass build-up cap was used for measurements obtained in air conditions. We present a useful measurement dataset for users of the Vero4DRT system.