期刊文献+
共找到1,656篇文章
< 1 2 83 >
每页显示 20 50 100
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction 被引量:1
1
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
在线阅读 下载PDF
The Integrated System of Aerial Photogrammetry and Tower Locations Optimization for Transmission Lines
2
作者 Xie Yuan, Pan Yijun, Fu Bin Northwest Power Design Institute 《Electricity》 1996年第4期45-48,共4页
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission... This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system. 展开更多
关键词 PRO The Integrated System of Aerial Photogrammetry and tower Locations Optimization for transmission lines
在线阅读 下载PDF
The changing process and trend of ground temperature around tower foundations of Qinghai-Tibet Power Transmission line 被引量:3
3
作者 YanLi Xie QiHao Yu +2 位作者 YanHui You ZhongQiu Zhang TingTao Gou 《Research in Cold and Arid Regions》 CSCD 2019年第1期13-20,共8页
After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing proce... After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change. 展开更多
关键词 Qinghai-Tibet Power transmission line tower FOUNDATION ground temperature change CHARACTERISTIC TREND
在线阅读 下载PDF
Dynamic Analysis of Overhead Transmission Lines under Turbulent Wind Loading 被引量:2
4
作者 Alok Dua Mathias Clobes +1 位作者 Thomas Hobbel Vasant Matsagar 《Open Journal of Civil Engineering》 2015年第4期359-371,共13页
Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode.... Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode. Finite element design software SAP2000 was used to model the towers and lines. Non-linear dynamic analysis including the large displacement effects was carried out. Macroscopic aspects of wind coherence along element length and integration time step were investigated. An approach is presented to compare the probabilistic dynamic response due to 7 different stochastically simulated wind fields with the response according to EN-50341. The developed model will be used to study the response recorded on a test line due to the actual wind speed time history recorded. It was found that static load from EN overestimated the strength of conductor cables. The response of coupled system considering towers and cables was found to be different from response of only cables with fixed supports. 展开更多
关键词 Dynamic Analysis Finite Element Method SAP2000 transmission towers transmission lines
在线阅读 下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
5
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
在线阅读 下载PDF
Dynamic Responses of Long-Span Transmission Tower-Line System Subjected to Broken Wires
6
作者 夏正春 李黎 +1 位作者 方秦汉 龙晓鸿 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期309-319,共11页
A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlineari... A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures. 展开更多
关键词 Electric transmission tower-line coupling Wire rupture Dynamic responses ANSYS/LS-DYNA
在线阅读 下载PDF
Evaluating transmission towers potentials during ground faults
7
作者 Maria VINTAN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期182-189,共8页
During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper pres... During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper presents analytical methods in order to determine the transmission towers potentials during ground faults,for long and short lines.The author developed a global systematic approach to calculate these voltages,which are dependent of a number of factors.Some of the most important factors are:magnitudes of fault currents,fault location with respect to the line terminals,conductor arrangement on the tower and the location of the faulted phase,the ground resistance of the faulted tower,soil resistivity,number,material and size of ground wires.The effects of these factors on the faulted tower voltages have been also examined for different types of power lines. 展开更多
关键词 Overhead transmission lines Ground fault tower potential
在线阅读 下载PDF
面向高压输电杆塔在线监测设备的多级无线供电系统设计与一体化绝缘子装置研制
8
作者 张民 张鑫 +3 位作者 刘野然 李勇 何正友 吴宁 《电网技术》 北大核心 2025年第2期834-843,I0115,共11页
感应取电+多中继无线供电为高压输电杆塔在线监测设备提供了一种不受天气影响且安全稳定的新型供电方式。然而,目前多中继无线供电技术还缺少完整的系统设计和高压环境下的运行验证。为此,该文提出了一套面向35kV电压等级的多中继无线... 感应取电+多中继无线供电为高压输电杆塔在线监测设备提供了一种不受天气影响且安全稳定的新型供电方式。然而,目前多中继无线供电技术还缺少完整的系统设计和高压环境下的运行验证。为此,该文提出了一套面向35kV电压等级的多中继无线供电系统方案,并研制了具有无线电能传输功能的一体化绝缘子装置。首先,基于系统电路模型,以实现恒压输出和零相角输入为目标,设计了五线圈-多中继无线供电系统的补偿电容参数,并给出了功率变换电路设计方案;其次,给出了多中继线圈与环氧树脂绝缘子的一体化封装方案和封装流程,并制作了一套一体化绝缘子装置;最后,通过实验验证了多中继无线供电系统的恒压特性,并且通过高压实验验证了融合多中继线圈的一体化绝缘子的绝缘性能以及在高压环境下实现无线能量传输的可行性。实验结果表明,整套设备输出功率达到44.38W,传输效率达84.5%,一体化绝缘子装置满足35kV电压等级绝缘耐压要求。 展开更多
关键词 输电杆塔在线监测设备 多中继无线供电 一体化绝缘子 恒压输出
在线阅读 下载PDF
海洋大气环境下输电塔线体系强风响应模拟分析
9
作者 程江洲 谢卓然 +3 位作者 李欣 张志强 邓海峰 郑皓文 《装备环境工程》 2025年第2期52-61,共10页
目的 以实际现场数据为基础,研究沿海地区输电塔线体系风灾薄弱点。方法 结合实际受灾情况,研究易受台风侵袭的输电线路所处地理气候特性,研究海洋大气腐蚀环境下输电塔钢构件腐蚀机理,并建立腐蚀深度以及力学性能退化时变模型。通过建... 目的 以实际现场数据为基础,研究沿海地区输电塔线体系风灾薄弱点。方法 结合实际受灾情况,研究易受台风侵袭的输电线路所处地理气候特性,研究海洋大气腐蚀环境下输电塔钢构件腐蚀机理,并建立腐蚀深度以及力学性能退化时变模型。通过建立塔线体系有限元模型,对其施加风荷载,重现其风致响应过程,并对风致倒塌结果进行分析。结果 塔脚与地基交接处的角钢全部压弯,塔身主材应力比超载6%~23%,造成整体失稳。塔头受扭严重,塔头曲臂实际承受荷载超过设计所能承受荷载20%~38%。结论 所提钢结构腐蚀时变模型能更好地拟合实际塔线体系抗风能力,且在台风背景下,塔体下部以及塔腿下部杆件的抗风能力对输电塔倒塌具有决定性作用,研究结果可为沿海输电线路设计提供参考。 展开更多
关键词 输电塔线体系 莫兰蒂台风 Cl^(-)腐蚀 海洋大气 有限元分析 风致倒塌
在线阅读 下载PDF
基于小波包分解卷积神经网络的停运输电线路故障识别方法
10
作者 王鑫明 王祥宇 +3 位作者 贾晓卜 张飞飞 李少博 胡永强 《电测与仪表》 北大核心 2025年第1期61-67,共7页
当输电线路处于热备用状态时,停运线路上仍可能发生短路故障,准确地判断停运线路的故障状态能有效地避免合闸到故障线路时对电力系统造成冲击并对故障的排除提供便利,因此有必要对停运输电线路进行故障识别。对于双回输电线路提出一种... 当输电线路处于热备用状态时,停运线路上仍可能发生短路故障,准确地判断停运线路的故障状态能有效地避免合闸到故障线路时对电力系统造成冲击并对故障的排除提供便利,因此有必要对停运输电线路进行故障识别。对于双回输电线路提出一种采用小波包分解生成的频谱图作为卷积神经网络(convolutional neural network,CNN)输入进行特征提取的停运线路故障识别方法。为减少人为提取特征产生的误差,首先对停运输电线路故障时三相电压暂态波形进行测量,采用小波包分解得到三相电压波形时频特性,最终通过CNN提取特征并进行故障分类。为验证该方法的故障识别效果,以河北省3条线路的实际数据为基础,在ATP-EMTP中建立500 kV同塔双回输电线路模型,为模拟现场各因素产生的误差在测得电压波形中加入10 dB高斯白噪声。结果表明,对热备用线路上故障状态识别准确率为99.98%,在一定程度上为停运线路的故障诊断及排除提供了参考。 展开更多
关键词 同塔双回输电线路 感应电压 小波包分解 时频分析 卷积神经网络 故障识别
在线阅读 下载PDF
“交改直”±200 kV同塔三回直流线路过电压研究
11
作者 陈松涛 陈兵 +4 位作者 吴巍 柏彬 赵会龙 廖黎明 杨庆 《浙江电力》 2025年第3期108-115,共8页
在同塔双回交流输电的设施基础上将其改造为同塔三回直流输电,无需大规模新增投资、消耗输电走廊资源便能显著提高输电容量。针对同塔三回直流线路的绝缘配合设计,依托国内首个交流改直流±200 kV扬州—镇江直流输电工程,对6种直流... 在同塔双回交流输电的设施基础上将其改造为同塔三回直流输电,无需大规模新增投资、消耗输电走廊资源便能显著提高输电容量。针对同塔三回直流线路的绝缘配合设计,依托国内首个交流改直流±200 kV扬州—镇江直流输电工程,对6种直流极线布置方案下过电压沿直流线路的分布特性和最大电压进行比较分析,并与单回架设直流线路的过电压进行对比。此外,分析了影响同塔架设三回直流线路过电压水平的因素。研究表明,同塔三回直流线路不同布置方式下线路过电压的沿线分布特性相近,且同塔三回架设线路过电压水平略低于单回架设线路;直流系统输送功率大小、直流滤波器主电容与土壤电阻率是影响过电压水平的主要因素。研究结果已为扬州—镇江直流工程的设计建造提供了技术依据。 展开更多
关键词 交流改直流输电 高压直流输电 同塔三回线路 线路过电压
在线阅读 下载PDF
单塔模型在塔-线体系风致动力响应中的适用性研究
12
作者 李玉学 陈鹏 《河北工程大学学报(自然科学版)》 2025年第1期18-25,共8页
以质量单元模拟输电线的质量,以弹簧单元作为边界条件模拟输电线平面内、外等效刚度,建立了输电塔线体系的单塔简化模型。以河北省唐山市乐亭县某一自立式钢管输电塔为工程背景,分别采用所建立的单塔简化模型和传统的三塔两线模型进行... 以质量单元模拟输电线的质量,以弹簧单元作为边界条件模拟输电线平面内、外等效刚度,建立了输电塔线体系的单塔简化模型。以河北省唐山市乐亭县某一自立式钢管输电塔为工程背景,分别采用所建立的单塔简化模型和传统的三塔两线模型进行结构风致动力响应计算,通过对比两者在不同风向角、不同输电线初始水平张力和不同输电线跨度下结构的风致动力响应,研究单塔简化模型的适用性。结果表明:在0°、45°和90°风向角下,保持输电线跨度不变,输电线两端初始水平张力在基准值基础上分别增加20%和减少20%时,两种计算模型所得结构在不同高度处的位移响应均方根和最大主材应力均方根基本吻合,且均呈现出随着输电塔高度的增加,二者偏差增大的规律;在不同输电线跨度下,两种计算模型所得结构动力响应的偏差随着输电线跨度增加而增大,其中位移响应均方根偏差较主材应力均方根偏差受跨度影响更显著,因此提出的单塔简化模型适用于跨度小于700 m的输电塔线体系风致动力响应计算。另外,在塔高较小的输电塔线体系中,提出的单塔简化模型具有较高的计算精度。 展开更多
关键词 输电塔 单塔简化模型 三塔两线模型 初始水平张力 风致动力响应
在线阅读 下载PDF
输电线路杆塔边坡稳定性分析
13
作者 刘明 郭金根 +1 位作者 朱文卫 董晗拓 《安全与环境学报》 北大核心 2025年第3期968-977,共10页
利用短基线集合成孔径雷达干涉测量(Small Baseline Subset Interferometric Synthetic Aperture Radar,SBAS-InSAR)技术对广州市内输电线路杆塔进行形变监测,评估其稳定性并识别潜在的地质灾害风险点。选取广州市内的木增科北线路为研... 利用短基线集合成孔径雷达干涉测量(Small Baseline Subset Interferometric Synthetic Aperture Radar,SBAS-InSAR)技术对广州市内输电线路杆塔进行形变监测,评估其稳定性并识别潜在的地质灾害风险点。选取广州市内的木增科北线路为研究对象,使用SBAS-InSAR技术处理45景Sentinel-1 SAR数据,获取杆塔区域的地表形变信息。同时,利用确定性系数法评估影响因子对滑坡发生的敏感度。结果表明,木增科北线整体稳定,特定区域有沉降漏斗,最大年平均沉降速率为-113 mm/a。分析发现高程对滑坡敏感度最高,坡度次之,确认了杆塔沿线形变特征及几个关键监测区域,揭示了影响滑坡的主要因素,为线路维护和灾害预防提供依据。 展开更多
关键词 安全工程 输电线路杆塔 短基线集合成孔径雷达干涉测量 形变监测 确定性系数法 灾害易发性
在线阅读 下载PDF
不同激励方式下输电塔模态参数识别研究
14
作者 杨磊 吕宝华 +1 位作者 王征 黄利平 《电力勘测设计》 2025年第1期30-37,共8页
风荷载是输电塔主要控制荷载,阻尼比的取值直接影响输电塔结构风荷载的设计值,输电铁塔阻尼比取值对输电线路的抗风设计有着重要意义。输电塔设计阶段的阻尼比取值按国标GB 50009—2012中钢结构标准取0.01,为准确研究输电塔的动力参数,... 风荷载是输电塔主要控制荷载,阻尼比的取值直接影响输电塔结构风荷载的设计值,输电铁塔阻尼比取值对输电线路的抗风设计有着重要意义。输电塔设计阶段的阻尼比取值按国标GB 50009—2012中钢结构标准取0.01,为准确研究输电塔的动力参数,对两基规格相同的110 kV单塔结构与塔-线体系输电塔进行现场测试。通过4种不同激励方式对输电塔施加激励,获取不同激励方式下输电塔加速度响应信号,采用修正平均周期图法对响应信号进行降噪处理,采用半功率带宽法对响应信号进行动力参数识别。研究结果表明:环境随机激振方法可以满足输电铁塔阻尼比辨识精度的要求;微幅振动条件下,是否挂线对输电塔顺横担方向阻尼比取值影响不大,顺导线方向塔-线体系相对于单塔结构阻尼比取值约减小20%。 展开更多
关键词 输电塔 塔-线体系 激振方法 加速度响应 阻尼比
在线阅读 下载PDF
750kV输电线路铁塔组立起吊孔布置探讨
15
作者 冯杨州 杨健 +3 位作者 张小勇 周延 张会芳 汪静 《电力安全技术》 2025年第1期26-29,共4页
针对750 kV输电线路铁塔组立阶段起吊孔布置问题进行研究,提出了一种有利于现场组塔施工的起吊孔布置方案。该方案结合实际施工经验,综合考虑起重机组塔及抱杆组塔施工方式,通过优化起吊孔布置位置和数量,最大程度降低了组塔施工过程中... 针对750 kV输电线路铁塔组立阶段起吊孔布置问题进行研究,提出了一种有利于现场组塔施工的起吊孔布置方案。该方案结合实际施工经验,综合考虑起重机组塔及抱杆组塔施工方式,通过优化起吊孔布置位置和数量,最大程度降低了组塔施工过程中的安全风险,提高了施工工作效率和质量。 展开更多
关键词 输电线路 铁塔组立 起吊孔布置 组塔施工
在线阅读 下载PDF
基于易损性分析的台风过程输电杆塔时变风险预测
16
作者 吴优 黄秀兵 王乃玉 《自然灾害学报》 北大核心 2025年第1期137-146,共10页
台风导致的输电杆塔倒塌会影响电网供电,进而造成严重的社会经济损失。因此,有必要在台风过程中对输电系统,特别是对输电杆塔进行风险预判,从而便于电力部门有效部署预防和减损措施。输电塔风致破坏易损性模型是风险评估的实用工具。结... 台风导致的输电杆塔倒塌会影响电网供电,进而造成严重的社会经济损失。因此,有必要在台风过程中对输电系统,特别是对输电杆塔进行风险预判,从而便于电力部门有效部署预防和减损措施。输电塔风致破坏易损性模型是风险评估的实用工具。结合数值气象预报风场,易损性模型能够有效支持台风实时行进过程中输电杆塔的风险预测。本研究通过考虑输电杆塔风致倒塌的物理机制和预报风速的时变特征,建立了基于精细化塔线体系有限元模型的易损性分析,并同时纳入脉动风时程不确定性的台风过程输电杆塔时变风险预判方法。以1909号超强台风利奇马行进过程中的我国东南沿海浙江省典型输电杆塔的风险预测为例,说明了所建立的易损性模型能够非常高效便捷地用于输电杆塔台风风险预报,呈现了输电杆塔实时风险预判模型的应用价值。 展开更多
关键词 有限元模型 输电塔线体系 易损性分析 风险预测 风致破坏 动力时程分析 PUSHOVER分析 电网韧性
在线阅读 下载PDF
架空输电线路施工中耐张塔取消临时拉线的优化方法
17
作者 吴昊 钱程 徐智东 《安徽电气工程职业技术学院学报》 2025年第1期6-14,共9页
架空输电线路施工时,通常在耐张塔架线反方向设置临时拉线及地锚平衡安装张力,以提高安全性。然而,随着电网建设快速发展,越来越多的架空线路经过山区、河网泥沼和城区,在这些地区临时拉线设置困难。因此,文章针对输电线路施工中耐张塔... 架空输电线路施工时,通常在耐张塔架线反方向设置临时拉线及地锚平衡安装张力,以提高安全性。然而,随着电网建设快速发展,越来越多的架空线路经过山区、河网泥沼和城区,在这些地区临时拉线设置困难。因此,文章针对输电线路施工中耐张塔取消临时拉线的优化方法进行研究:在耐张塔设计时,考虑安装工况下耐张塔未设置临时拉线的平衡张力,对杆塔构件进行局部加强;再通过数值仿真和现场试验研究杆塔在未设置临时拉线安装过程中的安全性。研究表明:加强后的耐张塔取消临时拉线后,在安装工况下仍处于安全状态。相较于设置临时拉线的耐张塔设计方案,文章提出的方案整体造价降低,综合效益提升,可为后续工程中耐张塔取消临时拉线的设计思路提供参考。 展开更多
关键词 输电线路 耐张塔 临时拉线 应力 位移
在线阅读 下载PDF
基于北斗卫星定位的输电线路杆塔位移分析
18
作者 宋豫晋 《电工技术》 2025年第3期142-145,共4页
为解决传统杆塔位移监测及时性差、准确度低、成本高等问题,提出基于北斗卫星定位的输电线路杆塔位移分析方法。通过对DID概念的了解,以某项目为例,描述项目输电线路杆塔故障,采用4颗北斗卫星初步定位杆塔,差分校准位移信息,由北斗位移... 为解决传统杆塔位移监测及时性差、准确度低、成本高等问题,提出基于北斗卫星定位的输电线路杆塔位移分析方法。通过对DID概念的了解,以某项目为例,描述项目输电线路杆塔故障,采用4颗北斗卫星初步定位杆塔,差分校准位移信息,由北斗位移监测终端完成定位,进行模拟试验,与模态参数法对比,检验该方法在输电线路杆塔位移识别中的可行性。实验结果表明,基于北斗卫星定位-DID的杆塔位移识别平均授时精度为7.51 ns,平均位移识别准确率为99.59%,平均位移识别误差为6.27 mm,应用效果优于模态参数法,是一种精度高、速度快的杆塔位移定位方法,定位结果可以作为杆塔运维管理的依据,保障杆塔使用安全。 展开更多
关键词 输电线路 杆塔 位移 北斗卫星定位 可行性检验
在线阅读 下载PDF
基于Python的塔基断面自动化成图研究
19
作者 董小刚 锁宝 +1 位作者 王彬 胡栋 《电力勘测设计》 2025年第2期62-66,共5页
塔基断面绘制在输电线路工程中具有重要意义,目前塔基断面的绘制方法大多基于AutoCAD的二次开发,其在环境配置及操作使用时存在一定的不便,基于Python开发一款新型的塔基断面绘制工具,优化以往对数据处理及环境配置、参数设置的要求,具... 塔基断面绘制在输电线路工程中具有重要意义,目前塔基断面的绘制方法大多基于AutoCAD的二次开发,其在环境配置及操作使用时存在一定的不便,基于Python开发一款新型的塔基断面绘制工具,优化以往对数据处理及环境配置、参数设置的要求,具有简便的界面操作及系统兼容效果,实现集数据读取、数据处理、塔基断面绘制于一体的自动化绘图工具,通过陇东—山东±800 kV特高压直流输电线路工程中的实例应用,表明提出的塔基断面成图工具可提升内业成图效率,成图质量也得到保证。 展开更多
关键词 塔基断面 输电线路 PYTHON 自动化成图
在线阅读 下载PDF
格构式输电铁塔主体结构的加固措施分析及其实践应用
20
作者 李双喜 孙明宝 《机械管理开发》 2025年第2期64-66,共3页
格构式输电铁塔在高压输电线路中有非常广泛的应用,但受多方面因素的影响,铁塔会存在失稳变形的问题,威胁输电安全。利用ABAQUS软件对格构式输电铁塔建立有限元仿真模型。分析发现主体结构3号杆存在失稳变形现象,与现实情况吻合。在薄... 格构式输电铁塔在高压输电线路中有非常广泛的应用,但受多方面因素的影响,铁塔会存在失稳变形的问题,威胁输电安全。利用ABAQUS软件对格构式输电铁塔建立有限元仿真模型。分析发现主体结构3号杆存在失稳变形现象,与现实情况吻合。在薄弱的主体结构部位通过设置十字型焊接板以及副主体结构的方式,强化其刚度和强度,使得相同工况条件下输电铁塔的综合性能更优。将优化方案应用到工程实践中,经过一年时间的实践应用发现达到了预期效果,为格构式输电铁塔的高质量运行打下了坚实的基础。 展开更多
关键词 输电线路 格构式铁塔 主体结构 加固措施
在线阅读 下载PDF
上一页 1 2 83 下一页 到第
使用帮助 返回顶部