The Transformer Short-Circuit Test and the High Power Laboratory in China-the Past,Present,and Future
1
作者 贺以燕 王茂松 《变压器》 北大核心 2005年第B08期32-37,共6页
We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
关键词 变压器 电路设计 高功率实验 能量转换
在线阅读 下载PDF
基于Transformer的DC/DC板级验证状态识别
2
作者 于海波 李杰 +2 位作者 胡陈君 夏俊辉 张伟 《集成电路与嵌入式系统》 2024年第5期94-100,共7页
为满足航天产品的高精度、高可靠性需求,实现元器件自主可控、芯片国产化及应用适应性验证十分必要,设计一种基于FPGA的国产DC/DC板级综合测试平台。在长时间的热学环境适应性板级验证项目中,为实现DC/DC器件应用板卡工作状态的实时监测... 为满足航天产品的高精度、高可靠性需求,实现元器件自主可控、芯片国产化及应用适应性验证十分必要,设计一种基于FPGA的国产DC/DC板级综合测试平台。在长时间的热学环境适应性板级验证项目中,为实现DC/DC器件应用板卡工作状态的实时监测,提出一种基于Transformer的智能识别算法。分别使用空载、负载电流3 A、负载电流5 A、高输入电压、低输入电压、短路状态下的DC DC输出序列,输入到Transformer模型中并利用注意力机制提取各序列的全局注意力特征,并对深度学习模型进行训练。实验结果表明,对于此6种工作状态数据集,Transformer模型识别的准确率为99.2%,具备良好的分类和监测性能,具有一定的工程应用价值。 展开更多
关键词 FPGA 板级测试 状态识别 深度学习 transformer模型
在线阅读 下载PDF
Analysis of capacitive voltage rise during off-line partial discharge tests on power transformers 被引量:1
3
作者 王烜 曹晓珑 +1 位作者 李云阁 刘英 《Journal of Shanghai University(English Edition)》 CAS 2007年第5期490-495,共6页
Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltag... Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios. 展开更多
关键词 transformer stray capacitance partial discharge test.
在线阅读 下载PDF
结合Transformer与Kolmogorov Arnold网络的分子扩增时序预测研究 被引量:1
4
作者 刘灿锋 孙浩 东辉 《图学学报》 CSCD 北大核心 2024年第6期1256-1265,共10页
随着医辽诊断和治疗干预技术的不断进步,医学时间序列数据呈现指数级增长。人工智能(AI),尤其是深度学习在挖掘医学时间序列数据潜在信息方面展现出巨大潜力。为此,首次提出将Transformer与Kolmogorov arnold网络(KAN)相结合的方法,用... 随着医辽诊断和治疗干预技术的不断进步,医学时间序列数据呈现指数级增长。人工智能(AI),尤其是深度学习在挖掘医学时间序列数据潜在信息方面展现出巨大潜力。为此,首次提出将Transformer与Kolmogorov arnold网络(KAN)相结合的方法,用于核酸扩增实验数据的预测分析。通过实验数据分析,证实模型在准确预测扩增趋势和终点值方面的有效性,终点值误差仅为1.87,R-square系数为0.98,且模型能准确识别不同样本类型的实验数据。进一步地,通过消融实验和超参数调优,深入探究模型各组成部分及其参数对预测性能的影响。最后,在911条临床数据上对10种深度学习模型进行泛化能力测试的结果表明,Transformer-KAN模型在预测准确性和泛化能力上均优于其他模型,不仅为改进大流行病常规诊断技术提供了新视角,还为进一步研究KAN模型及相应基础理论提供了实验佐证。 展开更多
关键词 深度学习 时间序列预测 核酸扩增检测技术 Kolmogorov-Arnold网络 transformer
在线阅读 下载PDF
Testing methods for 1100 kV UHVDC transformer 被引量:2
5
作者 Thomas Hammer Rene Wimmer +1 位作者 Karsten Loppach Ronny Fritsche 《Global Energy Interconnection》 2018年第2期103-107,共5页
1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electric... 1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electrical power.Available energy resources and consumption areas are often distributed inverse.As a consequence it is necessary to import electrical power to load center areas in an economic and efficient way. 展开更多
关键词 UHVDC In testing methods for 1100 kV UHVDC transformer
在线阅读 下载PDF
A Study on Measurement Error during Alternating Current Induced Voltage Tests on Large Transformers 被引量:1
6
作者 WANG Xuan LI Yun-ge +1 位作者 CAO Xiao-long LIU Ying 《International Journal of Plant Engineering and Management》 2006年第1期17-24,共8页
The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the wor... The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the working frequency. If the magnetizing inductance cannot compensate for the stray capacitance, the test sample turns into a capacitive load and a capacitive rise exhibits in the testing circuit. For self-restoring insulation, a method has been recommended in IEC60-1 that an unapproved measuring system be calibrated by an approved system at a voltage not less than 50% of the rated testing voltage, and the result then be extrapolated linearly. It has been found that this method leads to great error due to the capacitive rise if it is not correctly used during a withstand voltage test under certain testing conditions, especiaUy for a test on high voltage transformers with large capacity. Since the withstand voltage test is the most important means to examine the operation reliability of a transformer, and it can be destructive to the insulation, a precise measurement must be guaranteed. In this paper a factor, named as the capacitive rise factor, is introduced to assess the rise. The voltage measurement error during the calibration is determined by the parameters of the test sample and the testing facilities, as well as the measuring point. Based on theoretical analysis in this paper, a novel method is suggested and demonstrated to estimate the error by using the capacitive rise factor and other known parame- ters of the testing circuit. 展开更多
关键词 transformer test MEASUREMENT ERROR
在线阅读 下载PDF
Research on Numerical Simulation of 3D Leakage Magnetic Field and Short-circuit Impedance of Axial Dual-low-voltage Split-winding Transformer
7
作者 Yan Li Longnv Li +1 位作者 Yongteng Jing Fangxu Han 《Energy and Power Engineering》 2013年第4期1093-1096,共4页
It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and ... It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and short-circuit impedance model of axial dual-low-voltage split-winding transformer is established, and then the 2D and 3D leakage magnetic field are analyzed. Secondly, the short-circuit impedance and split parallel branch current distribution in different working conditions are calculated, which is based on field-circuit coupled method. At last, effectiveness and feasibility of the proposed model is verified by comparison between experiment, analysis and simulation. The results showed that the 3D analysis method is a better approach to calculate the short-circuit impedance, since its analytical value is more closer to the experimental value compared with the 2D analysis results, the finite element method calculation error is less than 2%, while the leakage flux method maximum error is 7.2%. 展开更多
关键词 Split-winding transformer short-circuit Impedance Field-circuit Coupled Current Distribution
在线阅读 下载PDF
Calculation of Eddy Current Loss and Short-circuit Force in SSZ11-50000/110 Power Transformer
8
作者 Yan Li Bo Zhang +2 位作者 Longnv Li Tongxun Yang Ning Wang 《Energy and Power Engineering》 2013年第4期1105-1108,共4页
The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination o... The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss. 展开更多
关键词 Power transformer FINITE Element short-circuit FORCE EDDY Current LOSS Surface IMPEDANCE Method
在线阅读 下载PDF
A Testing Method for Ratio Restraint Characteristics of Differential Relay Protection of Transformers
9
作者 Cao Zhihui Peng Chunyan Zhou Huaping 《Electricity》 2012年第5期44-47,共4页
In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slop... In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slope. Modulating the argument of current output from ONLLY testing equipment can make the relay protection device operate, thus, the data used for calculation would be obtained naturally after several trails. In order to make sure how effective that method could be, some experiment data is given as well. 展开更多
关键词 differential relay slope of ratio restraint characteristic relay testing relay protection of transformer
在线阅读 下载PDF
Measuring Technology of Temperature Based Transformer Internal on FBG Sensors 被引量:6
10
作者 LIU Jun CHEN Wei-gen +2 位作者 ZHAO Jian-bao LIANG Ya-feng ZHAO Xin 《高电压技术》 EI CAS CSCD 北大核心 2009年第3期539-543,共5页
关键词 电力变压器 温度 传感器 测量方法
在线阅读 下载PDF
Determination of failure degree of 1.2 kV SiC MOSFETs after short-circuit test using an improved test setup
11
作者 Shen Diao Jun Sun +4 位作者 Ziwei Zhou Zhenzhong Zhang Adolf Schöner Zedong Zheng Weiwei He 《Nanotechnology and Precision Engineering》 CAS CSCD 2020年第4期235-240,共6页
Analysis of the short-circuit characteristics of SiC metal-oxide-semiconductor field-effect transistors(MOSFETs)is very important for their practical application.This paper studies the SiC MOSFET short-circuit charact... Analysis of the short-circuit characteristics of SiC metal-oxide-semiconductor field-effect transistors(MOSFETs)is very important for their practical application.This paper studies the SiC MOSFET short-circuit characteristics with an improved test setup under different conditions.A high-current Si insulated gate bipolar transistor is used as a circuit breaker in the test circuit rather than the usual short-circuit test conducted without a circuit breaker.The test platform with a circuit breaker does not influence the calculation results regarding the shortcircuitwithstand time and energy,but the SiCMOSFETwill switch off after failure in a very short time.In addition,the degree of failure will be limited and confined to a small area,such that the damage to the chip will be clearly observable,which is significant for short-circuit failure analysis. 展开更多
关键词 SiC MOSFET short-circuit test Failure analysis
在线阅读 下载PDF
Study on the Effect of Multi-Type Current Transformers Hybrid Operation on Differential Protection of the Bus Based on Dynamic Simulation
12
作者 Wenbiao Liao Zexin Zhou +2 位作者 Rongrong Zhan Yanjun Li Zhengguang Chen 《Energy and Power Engineering》 2017年第4期1-11,共11页
This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission chara... This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures. 展开更多
关键词 DIFFERENTIAL Protection of the BUS Multi-Type Current transformer Hybrid Operation DYNAMIC SIMULATION test Method DYNAMIC SIMULATION test PLATFORM
在线阅读 下载PDF
Calculation of phase transformation latent heat based on cooling curves in end-quench test and its application in nickel-based superalloy
13
作者 Tian-yang ZHAO Pei FU +2 位作者 Zhuo CHEN Ping ZHOU Chao LI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2022年第5期1718-1727,共10页
To obtain the phase transformation latent heat corresponding to different cooling rates with low test workload and cost,the Newton thermal analysis method and the improved Newtonian thermal analysis method were discus... To obtain the phase transformation latent heat corresponding to different cooling rates with low test workload and cost,the Newton thermal analysis method and the improved Newtonian thermal analysis method were discussed based on the cooling curve obtained in the end-quench test.The validity of two methods was given by the latent heat calculation of 45^(#) steel.The results show that the relative error of latent heat is 5.20%through the improved Newtonian thermal analysis method,which is more accurate than the Newtonian thermal analysis method.Furthermore,the latent heat release of phase transformation of the self-designed CSU-A1 powder metallurgy nickel-based superalloy increases from 4.3 to 12.29 J/g when the cooling rate decreases from 50.15 to 33.40℃/min,because there is more sufficient time for the alloy microstructure to complete the phase transformation process when the cooling rate is smaller. 展开更多
关键词 cooling curve end-quench test Newtonian thermal analysis method phase transformation latent heat nickel-based superalloy
在线阅读 下载PDF
A Tool for the Assessment of the Electromagnetic Forces in Power Distribution Transformers
14
作者 A. da Costa Lopes M.A. Sanz-Bobi +3 位作者 L. Rouco R. Palacios L. Flores P. Cirujano 《Journal of Energy and Power Engineering》 2011年第10期972-977,共6页
This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagneti... This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagnetic lbrces as they have been compiled in earlier versions of the IEC standard 60076-5. The second model is based on a finite element model of the transformer using the software FEMM (Finite Element Method Magnetics). The paper shows how valid the analytical model is for design purposes. Results have been obtained and compared from both models in a number of actual power distribution transformers. It is possible to conclude that the analytical formulation provides satisfactory results for the design of power transformers compared to detailed finite element models. A tool has been designed for this purpose and the main features of it will be described in the paper. 展开更多
关键词 Electromagnetic forces power transformer short-circuit IEC 60076-5.
在线阅读 下载PDF
Optimization of short-circuit transition parameters of Q235B steel GMAW based on orthogonal gray relational analysis
15
作者 陈昌荣 唐宝林 +2 位作者 叶宇杰 练国富 黄旭 《China Welding》 CAS 2024年第2期39-49,共11页
In gas metal arc welding(GMAW)process,the short-circuit transition was the most typical transition observed in molten metal droplets.This paper used orthogonal tests to explore the coupling effect law of welding proce... In gas metal arc welding(GMAW)process,the short-circuit transition was the most typical transition observed in molten metal droplets.This paper used orthogonal tests to explore the coupling effect law of welding process parameters on the quality of weld forming under short-circuit transition,the design of 3 factors and 3 levels of a total of 9 groups of orthogonal tests,welding current,welding voltage,welding speed as input parameters:effective area ratio,humps,actual linear power density,aspect ratio,Vickers hardness as output paramet-ers(response targets).Using range analysis and trend charts,we can visually depict the relationship between input parameters and a single output parameter,ultimately determining the optimal process parameters that impact the single output index.Then combined with gray the-ory to transform the three response targets into a single gray relational grade(GRG)for analysis,the optimal combination of the weld mor-phology parameters as follows:welding current 100 A,welding voltage 25 V,welding speed 30 cm/min.Finally,validation experiments were conducted,and the results showed that the error between the gray relational grade and the predicted value was 2.74%.It was observed that the effective area ratio of the response target significantly improved,validating the reliability of the orthogonal gray relational method. 展开更多
关键词 short-circuit transition orthogonal test gray relational forming quality
在线阅读 下载PDF
A Practical Guide to Statistical Tests in the Biomedical Field: From Parametric to Nonparametric, Where and How?
16
作者 Adil Gourinda Hicham El Bouri +5 位作者 Faïza Charif Zaynab Mahdi Fadila Bousgheiri Karima Sammoud Saloua Lemrabett Adil Najdi 《Journal of Biosciences and Medicines》 2024年第11期1-14,共14页
Healthcare decisions are based on scientific evidence obtained from medical studies by gathering data and analyzing it to obtain the best results. When analyzing data, biostatistics is a powerful tool, but healthcare ... Healthcare decisions are based on scientific evidence obtained from medical studies by gathering data and analyzing it to obtain the best results. When analyzing data, biostatistics is a powerful tool, but healthcare professionals lack knowledge in this field. This lack of knowledge can manifest itself in situations such as choosing the wrong statistical test for the right situation or applying a statistical test without checking its assumptions, leading to inaccurate results and misleading conclusions. With the help of this “narrative review”, the aim is to bring biostatistics closer to healthcare professionals by answering certain questions: how to describe the distribution of data? how to assess the normality of data? how to transform data? and how to choose between nonparametric and parametric tests? Through this work, our hope is that the reader will be able to choose the right test for the right situation, in order to obtain the most accurate results. 展开更多
关键词 Teaching Statistics Distribution NORMALITY transformATION Nonparametric test Parametric test
在线阅读 下载PDF
Cautionary Remarks When Testing Agreement between Two Raters for Continuous Scale Measurements: A Tutorial in Clinical Epidemiology with Implementation Using R
17
作者 Mohamed M. Shoukri 《Open Journal of Epidemiology》 2024年第1期56-74,共19页
Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting sub... Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting subject-wise differences between raters against subject-wise averages. In order to scientifically assess agreement, Bartko recommended combining the graphical approach with the statistical analytic procedure suggested by Bradley and Blackwood. The advantage of using this approach is that it enables significance testing and sample size estimation. We noted that the direct use of the results of the regression is misleading and we provide a correction in this regard. Methods: Graphical and linear models are used to assess agreements for continuous scale measurements. We demonstrate that software linear regression results should not be readily used and we provided correct analytic procedures. The degrees of freedom of the F-statistics are incorrectly reported, and we propose methods to overcome this problem by introducing the correct analytic form of the F statistic. Methods for sample size estimation using R-functions are also given. Results: We believe that the tutorial and the R-codes are useful tools for testing and estimating agreement between two rating protocols for continuous scale measurements. The interested reader may use the codes and apply them to their available data when the issue of agreement between two raters is the subject of interest. 展开更多
关键词 Limits of Agreement Pitman and Morgan tests test of Parallelism The Arcsine Variance Stabilizing transformation Sample Size Estimation
在线阅读 下载PDF
换流变真空有载分接开关谐波电流切换试验技术的研究与分析
18
作者 张长虹 范广伟 +3 位作者 邓军 王培人 周海滨 谢志成 《高压电器》 北大核心 2025年第2期26-34,共9页
换流变压器有载分接开关是实现换流变压器调压的核心部件,对保证电力系统电压稳定性起到重要的作用。随着柔性直流输电技术的发展,有载分接开关切换含有谐波分量的负载电流工况日益凸显,经常在多次谐波叠加的复杂工况下进行切换操作,因... 换流变压器有载分接开关是实现换流变压器调压的核心部件,对保证电力系统电压稳定性起到重要的作用。随着柔性直流输电技术的发展,有载分接开关切换含有谐波分量的负载电流工况日益凸显,经常在多次谐波叠加的复杂工况下进行切换操作,因此切换的负载电流零点会有较大的电流变化率,其显著增加了分接开关的切换负荷,尤其对真空有载分接开关中的真空灭弧室转换电流能力提出了极大挑战。因此,文中针对换流变压器应用的真空有载分接开关的谐波电流切换能力的验证开展了相应的试验技术研究,并通过建立的谐波电流切换试验条件开展了性能验证。所获得的试验结果和分析内容将对真空有载分接开关谐波电流切换性能考核方法的建立提供技术支撑。 展开更多
关键词 换流变压器 有载分接开关 谐波电流 切换试验
在线阅读 下载PDF
基于绕组首饼温度及温度梯度的变压器热点模型
19
作者 范晓舟 刘云鹏 +3 位作者 律方成 李欢 徐永超 闫泽玉 《中国电机工程学报》 北大核心 2025年第1期361-369,I0030,共10页
变压器热点温度是衡量变压器负载潜力及运行安全性的重要指标,是变压器状态监测以及预测的重点。绕组底部首饼直接与散热片回流的冷油接触,周围油温与冷油近似相等,可以较为准确地分析其散热。该文从变压器传热原理出发,提出一种新的热... 变压器热点温度是衡量变压器负载潜力及运行安全性的重要指标,是变压器状态监测以及预测的重点。绕组底部首饼直接与散热片回流的冷油接触,周围油温与冷油近似相等,可以较为准确地分析其散热。该文从变压器传热原理出发,提出一种新的热点温度计算模型。首先,基于理论推导建立绕组首饼温度的控制方程,并使用热电类比方法建立可用于实际运行的绕组首饼局部热路模型。通过对一台内置传感光纤的110 kV油浸式变压器进行11级不同负载共21 h温升试验,获得不同负载率下绕组温度变化情况,并提出基于绕组首饼温度及绕组温度梯度的热点温度模型。基于局部热路模型,使用负载率及散热片进出口油温作为输入变量,成功预测绕组首饼温度。随后,建立绕组整体温度梯度的指数、差分方程模型,并基于提出的热点计算模型对连续变负载试验的结果进行预测。结果表明,模型预测均方根误差为4.02 K,相较传统模型,最大误差降低21%,验证所提计算模型的有效性。 展开更多
关键词 变压器 热点温度 温度梯度 温升试验 分布式光纤传感
在线阅读 下载PDF
装备自然环境试验数据工程建设方法与实践
20
作者 张伦武 周堃 +5 位作者 谭甜甜 王竟成 舒畅 周俊炎 李旭 谢婧 《装备环境工程》 2025年第1期186-195,共10页
简要介绍了装备自然环境试验数据的内涵及其重要性,分析了国外自然环境试验站网、数据资源深层次开发利用、数据共享服务等建设现状。重点从基础设施与服务保障能力、数据治理管控模式等方面,概述了国内装备自然环境试验数据工程建设现... 简要介绍了装备自然环境试验数据的内涵及其重要性,分析了国外自然环境试验站网、数据资源深层次开发利用、数据共享服务等建设现状。重点从基础设施与服务保障能力、数据治理管控模式等方面,概述了国内装备自然环境试验数据工程建设现状与成效,提出了要进一步激活要素价值潜能、创新数据共建共享服务模式、创新数据服务体制机制、加快推进产业数字化等建议。 展开更多
关键词 数据工程 自然环境试验站网 环境适应性 数据治理 共建共享 数字化转型
在线阅读 下载PDF