This paper investigates the effect of the Phase Angle Error of a Constant Amplitude Voltage signal in determining the Total Vector Error (TVE) of the Phasor Measurement Unit (PMU) using MATLAB/Simulink. The phase angl...This paper investigates the effect of the Phase Angle Error of a Constant Amplitude Voltage signal in determining the Total Vector Error (TVE) of the Phasor Measurement Unit (PMU) using MATLAB/Simulink. The phase angle error is measured as a function of time in microseconds at four points on the IEEE 14-bus system. When the 1 pps Global Positioning System (GPS) signal to the PMU is lost, sampling of voltage signals on the power grid is done at different rates as it is a function of time. The relationship between the PMU measured signal phase angle and the sampling rate is established by injecting a constant amplitude signal at two different points on the grid. In the simulation, 64 cycles per second is used as the reference while 24 cycles per second is used to represent the fault condition. Results show that a change in the sampling rate from 64 bps to 24 bps in the PMUs resulted in phase angle error in the voltage signals measured by the PMU at four VI Measurement points. The phase angle error measurement that was determined as a time function was used to determine the TVE. Results show that (TVE) was more than 1% in all the cases.展开更多
基于单一线路两端的监控与数据采集系统(supervisory control and data acquisition system,SCADA)和相量采集装置(phasor measurement unit,PMU)多时段量测信息,建立了5种独立线路的约束最小二乘参数估计模型,其中,量测方程分别由线路...基于单一线路两端的监控与数据采集系统(supervisory control and data acquisition system,SCADA)和相量采集装置(phasor measurement unit,PMU)多时段量测信息,建立了5种独立线路的约束最小二乘参数估计模型,其中,量测方程分别由线路两端有功、无功和电压幅值的SCADA量测、电流与电压相量的PMU量测以及线路两端电压相角差的PMU虚拟量测组合形成,约束方程为参数变量的上下限约束。采用Matlab的lsqnonlin优化函数求解参数估计问题,并基于多条典型线路的模拟量测信息仿真分析了所有模型的适用条件。结果表明,在负荷较重、线路较长条件下,利用所建含PMU量测的4种模型,都可以有效估计出线路的阻抗参数。展开更多
随着分布式新能源渗透率不断提高,智能配电网电力电子化趋势明显,电气参数更加复杂,亟需研究适用于配电网的同步相量测量装置(Synchrophasor measurement unit for distribution network,D-PMU)。然而,现有通信协议与条件无法满足D-PMU...随着分布式新能源渗透率不断提高,智能配电网电力电子化趋势明显,电气参数更加复杂,亟需研究适用于配电网的同步相量测量装置(Synchrophasor measurement unit for distribution network,D-PMU)。然而,现有通信协议与条件无法满足D-PMU的接入需求。针对该问题,该文设计一种适用于D-PMU的基频相量、谐波/间谐波同步测量、异步传输的结构框架,提出一种谐波/间谐波的数据传输协议,减少了通信负担。在上述框架的条件下,分析网络通信延时与丢包率的影响因素,搭建通信性能测试平台,进行通信性能实际测试,验证所提通信方法的可行性,并根据测试结果提出一种D-PMU通信接入参数的设置方法。展开更多
同步相量测量单元(phasor measurements units,PMU)因能测得高精度的同步相量数据而被广泛应用于电力系统中,而传统的监控及数据采集系统(supervisory control and data acquisition,SCADA)是电力系统运行和静态安全监视的基础。文中提...同步相量测量单元(phasor measurements units,PMU)因能测得高精度的同步相量数据而被广泛应用于电力系统中,而传统的监控及数据采集系统(supervisory control and data acquisition,SCADA)是电力系统运行和静态安全监视的基础。文中提出了一种PMU与SCADA数据共存的数学模型用于电力系统状态估计。该模型在保留原有SCADA数据的同时,通过虚拟测量方法对PMU观测范围进行大范围拓展,提高数据冗余度及状态估计的精度。仿真结果表明,该方法具有较高的估计精度,且不受网络拓扑结构和PMU数量限制,适于SCADA和PMU数据共存系统。展开更多
针对传统静态状态估计方法的缺点,提出了一种改进的电力系统状态估计方法,即将部分节点相量测量单元(phasor measurement unit,PMU)量测数据与监控数据采集(supervisory control and data acquisition,SCADA)量测数据融合进行电力系统...针对传统静态状态估计方法的缺点,提出了一种改进的电力系统状态估计方法,即将部分节点相量测量单元(phasor measurement unit,PMU)量测数据与监控数据采集(supervisory control and data acquisition,SCADA)量测数据融合进行电力系统的全网状态估计。该方法简化了系统的雅可比矩阵,缩短了计算时间。文章研究了PMU和SCADA系统融合改进后的快速分解法,针对SCADA量测数据的缺点,通过历史数据库对潮流数据进行预测,并依据PMU量测量对系统进行分析,继而进行系统全网状态的动态监测。通过算例证明,与传统的估计方法相比,该方法改善了状态估计的精确性,减少了迭代次数,细致地描绘了电网状态的变化过程,为调度中心下一步的决策提供了依据。展开更多
文摘This paper investigates the effect of the Phase Angle Error of a Constant Amplitude Voltage signal in determining the Total Vector Error (TVE) of the Phasor Measurement Unit (PMU) using MATLAB/Simulink. The phase angle error is measured as a function of time in microseconds at four points on the IEEE 14-bus system. When the 1 pps Global Positioning System (GPS) signal to the PMU is lost, sampling of voltage signals on the power grid is done at different rates as it is a function of time. The relationship between the PMU measured signal phase angle and the sampling rate is established by injecting a constant amplitude signal at two different points on the grid. In the simulation, 64 cycles per second is used as the reference while 24 cycles per second is used to represent the fault condition. Results show that a change in the sampling rate from 64 bps to 24 bps in the PMUs resulted in phase angle error in the voltage signals measured by the PMU at four VI Measurement points. The phase angle error measurement that was determined as a time function was used to determine the TVE. Results show that (TVE) was more than 1% in all the cases.
文摘基于单一线路两端的监控与数据采集系统(supervisory control and data acquisition system,SCADA)和相量采集装置(phasor measurement unit,PMU)多时段量测信息,建立了5种独立线路的约束最小二乘参数估计模型,其中,量测方程分别由线路两端有功、无功和电压幅值的SCADA量测、电流与电压相量的PMU量测以及线路两端电压相角差的PMU虚拟量测组合形成,约束方程为参数变量的上下限约束。采用Matlab的lsqnonlin优化函数求解参数估计问题,并基于多条典型线路的模拟量测信息仿真分析了所有模型的适用条件。结果表明,在负荷较重、线路较长条件下,利用所建含PMU量测的4种模型,都可以有效估计出线路的阻抗参数。
文摘随着分布式新能源渗透率不断提高,智能配电网电力电子化趋势明显,电气参数更加复杂,亟需研究适用于配电网的同步相量测量装置(Synchrophasor measurement unit for distribution network,D-PMU)。然而,现有通信协议与条件无法满足D-PMU的接入需求。针对该问题,该文设计一种适用于D-PMU的基频相量、谐波/间谐波同步测量、异步传输的结构框架,提出一种谐波/间谐波的数据传输协议,减少了通信负担。在上述框架的条件下,分析网络通信延时与丢包率的影响因素,搭建通信性能测试平台,进行通信性能实际测试,验证所提通信方法的可行性,并根据测试结果提出一种D-PMU通信接入参数的设置方法。
文摘同步相量测量单元(phasor measurements units,PMU)因能测得高精度的同步相量数据而被广泛应用于电力系统中,而传统的监控及数据采集系统(supervisory control and data acquisition,SCADA)是电力系统运行和静态安全监视的基础。文中提出了一种PMU与SCADA数据共存的数学模型用于电力系统状态估计。该模型在保留原有SCADA数据的同时,通过虚拟测量方法对PMU观测范围进行大范围拓展,提高数据冗余度及状态估计的精度。仿真结果表明,该方法具有较高的估计精度,且不受网络拓扑结构和PMU数量限制,适于SCADA和PMU数据共存系统。
文摘针对传统静态状态估计方法的缺点,提出了一种改进的电力系统状态估计方法,即将部分节点相量测量单元(phasor measurement unit,PMU)量测数据与监控数据采集(supervisory control and data acquisition,SCADA)量测数据融合进行电力系统的全网状态估计。该方法简化了系统的雅可比矩阵,缩短了计算时间。文章研究了PMU和SCADA系统融合改进后的快速分解法,针对SCADA量测数据的缺点,通过历史数据库对潮流数据进行预测,并依据PMU量测量对系统进行分析,继而进行系统全网状态的动态监测。通过算例证明,与传统的估计方法相比,该方法改善了状态估计的精确性,减少了迭代次数,细致地描绘了电网状态的变化过程,为调度中心下一步的决策提供了依据。