Purpose–The brake pipe system was an essential braking component of the railway freight trains,but the existing E-type sealing rings had problems such as insufficient low-temperature resistance,poor heat stability an...Purpose–The brake pipe system was an essential braking component of the railway freight trains,but the existing E-type sealing rings had problems such as insufficient low-temperature resistance,poor heat stability and short service life.To address these issues,low-phenyl silicone rubber was prepared and tested,and the finite element analysis and experimental studies on the sealing performance of its sealing rings were carried out.Design/methodology/approach–The low-temperature resistance and thermal stability of the prepared lowphenyl silicone rubber were studied using low-temperature tensile testing,differential scanning calorimetry,dynamic thermomechanical analysis and thermogravimetric analysis.The sealing performance of the lowphenyl silicone rubber sealing ring was studied by using finite element analysis software abaqus and experiments.Findings–The prepared low-phenyl silicone rubber sealing ring possessed excellent low-temperature resistance and thermal stability.According to the finite element analysis results,the finish of the flange sealing surface and groove outer edge should be ensured,and extrusion damage should be avoided.The sealing rings were more susceptible to damage in high compression ratio and/or low-temperature environments.When the sealing effect was ensured,a small compression ratio should be selected,and rubbers with hardness and elasticity less affected by temperature should be selected.The prepared low-phenyl silicone rubber sealing ring had zero leakage at both room temperature(RT)and�508C.Originality/value–The innovation of this study is that it provides valuable data and experience for the future development of the sealing rings used in the brake pipe flange joints of the railway freight cars in China.展开更多
AIM:To evaluate the efficacy and safety of silicone oil(SO)as a corneal lubricant to improve visualization during vitrectomy.METHODS:Patients who underwent vitreoretinal surgery were divided into two groups.Group 1 wa...AIM:To evaluate the efficacy and safety of silicone oil(SO)as a corneal lubricant to improve visualization during vitrectomy.METHODS:Patients who underwent vitreoretinal surgery were divided into two groups.Group 1 was operated on with initial SO(Oxane 5700)as a corneal lubricant.Group 2 was operated on with initial lactated ringer’s solution(LRS)and then replaced with SO as required.Fundus clarity was scored during the surgery.Fluorescein staining was performed to determine the damage to corneal epithelium.RESULTS:Totally 114 eyes of 114 patients were included.Single SO use maintained a clear cornea and provided excellent visualization of surgical image.In group 1,the fundus clarity was grade 3 in 41/45 eyes and grade 2 in 4/45 eyes.In group 2,corneal edema frequently occurred after initial LRS use.The fundus clarity was grade 3 in 19/69 eyes,2 in 37/69 eyes and 1 in 13/69 eyes(P<0.05).SO was applied in 29 eyes of initial LRS use with subsequent corneal edema,which eliminated the corneal edema in 26 eyes.Corneal fluorescein staining score in group 1 was 0 in 28 eyes,1 in 11 eyes and 2 in 6 eyes,and 40,20 and 9,respectively,in group 2(all P>0.05).CONCLUSION:The use of SO as a corneal lubricant is effective and safe for preserving and improving corneal clarity and providing clear surgical field during vitrectomy.展开更多
AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.MET...AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.展开更多
BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis ...BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis include the removal of silicone oil,washout of the vitreous cavity,administration of intravitreal antibiotics,and reinjection of silicone oil.CASE SUMMARY Herein,we report the case of a 39-year-old man with unilateral endophthalmitis after pars plana vitrectomy and silicone oil tamponade.Intravitreal injections of full-dose antibiotics and anterior chamber washout were used to treat the patient.No signs of retinal toxicity were observed during the follow-up period.CONCLUSION Intravitreal full-dose antibiotic injections and anterior chamber washout are promising alternatives to traditional therapies for endophthalmitis in silicone oilfilled eyes.展开更多
BACKGROUND We report a case of eye-penetrating injury in which a massive silicone oil migration into the patient’s subconjunctival space and orbit occurred after vitrectomy.CASE SUMMARY A 30-year-old male patient sou...BACKGROUND We report a case of eye-penetrating injury in which a massive silicone oil migration into the patient’s subconjunctival space and orbit occurred after vitrectomy.CASE SUMMARY A 30-year-old male patient sought medical attention at Ganzhou People’s Hospital after experiencing pain and vision loss in his left eye due to a nail wound on December 9,2023.Diagnosis of penetrating injury caused by magnetic foreign body retention in the left eye and hospitalization for treatment.On December 9,2023,pars plana vitrectomy was performed on the left eye for intraocular foreign body removal,abnormal crystal extraction,retinal photocoagulation.Owing to the discovery of retinal detachment at the posterior pole during surgery,silicone oil was injected to fill the vitreous body,following which upper conjunctival bubble-like swelling was observed.Postoperative orbital computed tomography(CT)review indicated migration of silicone oil to the subconjunctival space and orbit through a self-permeable outlet.On December 18,2023,the patient sought treatment at the First Affiliated Hospital of Nanchang University,China.The patient presented with a pronounced foreign body sensation following left eye surgery.On December 20,2023,the foreign body was removed from the left eye frame and an intraocular examination was conducted.The posterior scleral tear had closed,leading to termination of the surgical procedure following supplementary laser treatment around the tear.The patient reported a significant reduction in ocular surface symptoms just one day after surgery.Furthermore,a notable decrease in the migration of silicone oil was observed in orbital CT scans.CONCLUSION The timing of silicone oil injection for an eye-penetrating injury should be carefully evaluated to avoid the possibility of silicone oil migration.展开更多
Introduction: RRD (Rhegmatogenous Retinal Detachment) is a separation between the neuroepithelium and the pigment epithelium due to the passage of fluid through a retinal dehiscence. It constitutes a major ophthalmolo...Introduction: RRD (Rhegmatogenous Retinal Detachment) is a separation between the neuroepithelium and the pigment epithelium due to the passage of fluid through a retinal dehiscence. It constitutes a major ophthalmologic emergency. Its management is primarily surgical, either through external or internal approaches, with tamponade using gas or silicone oil. The purpose of this study was to report the various complications associated with the use of silicone oil in vitreoretinal surgery. Patients et methods: We conducted a retrospective, descriptive, and analytical study from October 1, 2020, to October 31, 2023, which included all patients who underwent surgery for RRD using three-port vitrectomy (3PV) with tamponade using 1000 centistoke silicone oil (Group 1) and 5000 centistoke silicone oil (Group 2). All patients underwent a complete ophthalmologic examination and were operated on by the same surgeon. Data analysis was performed using Excel software. Results: Overall, 31 patient files representing 33 eyes were collected, with a mean age of 48.83 years and a sex ratio of 4.16. Group 1 consisted of 16 eyes (48.48%), and Group 2 consisted of 17 eyes (51.51%). The different complications observed were cataracts in all phakic subjects, accounting for 57.57%;ocular hypertonia in 69.69% (27.27% in Group 1;42.42% in Group 2);anterior chamber silicone oil migration in 24.24% (9.09% in Group 1;15.15% in Group 2);recurrence of retinal detachment in 21.21% (6.06% in Group 1;15.15% in Group 2);and silicone oil emulsification in 24.24% (15.15% in Group 1;9.09% in Group 2). Additionally, there was one case of corneal degeneration in Group 1. Conclusion: Silicone oil is an effective tamponade agent used in the treatment of retinal detachments. Close patient follow-up is necessary due to the complications associated with its use, which can occur either early or late after surgery.展开更多
Silicone is a kind of polymer material with high cross-linked structure,which is com-posed by Si-O-Si main chain.Due to the special molecular chain structure,silicone mate-rials are characterized by oxidation resistan...Silicone is a kind of polymer material with high cross-linked structure,which is com-posed by Si-O-Si main chain.Due to the special molecular chain structure,silicone mate-rials are characterized by oxidation resistance,aging resistance,high and low temperature resistance and chemical corrosion resistance.Moreover,silicone materials have process-able properties,simple forming process,good mechanical property,non-toxic and pollution-free.Therefore,silicone has been widely concerned by researchers at home and abroad.In this paper,the main research progress and application directions of carbon-silicone composite at home and abroad in recent years are reviewed.展开更多
AIM:To compare success rates and complications of Densiron 68 and 1000cSt silicone oil (SO) in the management of rhegmatogenous retinal detachment (RRD) with inferior breaks (IBs). METHODS:Totally 61 eyes of 61 consec...AIM:To compare success rates and complications of Densiron 68 and 1000cSt silicone oil (SO) in the management of rhegmatogenous retinal detachment (RRD) with inferior breaks (IBs). METHODS:Totally 61 eyes of 61 consecutive patients with RRD with IBs were assigned to pars plana vitrectomy (PPV) with Densiron (n =31) or PPV with SO (n=30) in order of presentation. SO and Densiron removal was performed 3 months after initial surgery. Follow up visits were terminated 6 months after SO removal. ·RESULTS:With a single operation, the Densiron group showed 84% and SO 74% reattachment. With further surgery, both groups showed 90% reattachment. Complications such as cataract, raised intraocular pressure (IOP), inflammatory reaction, macular epiretinal membranes, and emulsification of SO were seen in both groups. CONCLUSION:Densiron and SO are found to have similar success rates and complications.展开更多
AIM:To investigate the safety and efficacy of sticky silicone oil(SSO)removal using a 22-gauge vein detained needle and inner limiting membrane(ILM)wrap-and-peel technique.METHODS:This retrospective consecutive case s...AIM:To investigate the safety and efficacy of sticky silicone oil(SSO)removal using a 22-gauge vein detained needle and inner limiting membrane(ILM)wrap-and-peel technique.METHODS:This retrospective consecutive case series reviewed the records of patients with a history of retinal detachment who had received silicone oil and perfluorocarbon liquid(PFCL)as intraocular tamponades.Patients were included in the analysis if they exhibited SSO remnants during silicone oil removal.The aspiration of most of the SSO remnants was performed by a 22-gauge vein detained needle.The small amounts of droplets adhered to the macula and epi-macular membrane were subsequently removed by the ILM warp-and-peel technique.The anatomical and functional outcomes,and postoperative complications were recorded.In vitro experiments were performed to simulate the formation of SSO remnants in four groups.RESULTS:Of 711 patients who underwent silicone oil removal during the study period,9 patients exhibited SSO remnants and underwent follow-up for at least 3mo.Seven eyes(78%)underwent the ILM wrap-and-peel technique to completely remove small droplets of SSO that were glued to the macula and epi-macular membrane.No obvious complications occurred.Postoperative optical coherence tomography revealed normal retinal structure in all patients.In vitro analyses showed that balanced salt solution and prolonged vibration(for 1wk)had the strongest effects on silicone oil and PFCL compound opacities.CONCLUSION:SSO remnants could be removed in an intact manner and without complications,using a vein detained needle-assisted and ILM wrap-and-peel technique.The findings suggest that PFCL and infusion fluid should be completely removed before silicone oil injection to prevent SSO formation.展开更多
A silicone acrylate micro-emulsion of multipolymer was prepared by seed emulsion polymerization. The effects of polymerization process, emulsifier rate and amount, initiator rate and amount, polymerization temperature...A silicone acrylate micro-emulsion of multipolymer was prepared by seed emulsion polymerization. The effects of polymerization process, emulsifier rate and amount, initiator rate and amount, polymerization temperature, functional monomers, titration time on performances of emulsion have been discussed in detail.展开更多
Background: Silicone oil (SO) has been demonstrated with concrete efficacy and safety in the therapy of complex vitreoretinal diseases. SO is schemed to be cleared within several weeks or months after tamponade, but i...Background: Silicone oil (SO) has been demonstrated with concrete efficacy and safety in the therapy of complex vitreoretinal diseases. SO is schemed to be cleared within several weeks or months after tamponade, but it’s inevitable for permanent or residual SO in a fraction of patients under extremely complicated clinical conditions. Here, we presented a case of silicone oil removal after 10 years, mainly to observe the disadvantages of long-term persistence. Case presentation: A 69-year-old female with pathologic myopia denied trauma history who had undergone pars plana vitrectomy (PPV), retinal reattachment, laser, and silicone oil tamponade in 2012 presented to our hospital with eye pain and headache, no light perception of her right eye for six months. The slit-lamp biomicroscopy examination for OD indicated evident conjunctival congestion, new blood vessels invasion to the limbus, foggy edema of corneal epithelium, folds of Descemet’s membrane and corneal endothelial edema. There were obvious emulsified silicone oil particles above the anterior chamber. Goldmann’s applanation tonometry test revealed the intraocular pressure was as high as 45/17mmHg. From ocular ultrasound, we saw that the vitreous cavity was filled with silicone oil in right eye;as for the left eye, it showed marked axial elongation and posterior scleral staphyloma. We were unable to obtain more information from fundus photography and macular optical coherence tomography (OCT) due to edema of the cornea. After the silicone oil was removed successfully from her vitreous cavity, although there was no improvement in the patient’s vision (no light perception), she was still satisfied with the relief from eye pain and headache benefited from the reduction of high intraocular pressure (Goldmann’s intraocular pressure decreased to 19/14mmHg). Conclusion: Patients after PPV should remove silicone oil in time to avoid corneal damage, intraocular hypertension, lens opacity and retinal damage induced by long-term silicone tamponade.展开更多
Objective The aim of this study was to investigate macular perfusion changes and ganglion cell complex(GCC)loss in patients with unexplained visual loss following vitrectomy and silicone oil(SO)tamponade,and to evalua...Objective The aim of this study was to investigate macular perfusion changes and ganglion cell complex(GCC)loss in patients with unexplained visual loss following vitrectomy and silicone oil(SO)tamponade,and to evaluate the correlation between retinal blood flow and GCC loss using optical coherence tomography angiography(OCTA)and optical coherence tomography(OCT).Methods This retrospective study included seven eyes(seven patients)with unexpected visual loss after vitrectomy and SO tamponade.OCTA was used to evaluate the alterations in retinal vessel density(VD)in the superficial capillary plexus(SCP),deep capillary plexus(DCP),and radial peripapillary capillary plexus(RPCP).OCT was used to measure the thickness of GCC and retinal nerve fiber layer(RNFL).Medical records of patients were reviewed.Results Quantitative analysis of OCTA images revealed a significant reduction in SCP VD in the affected eyes compared with the controls(all sections P<0.05).No difference was found in GCC thickness,but FLV(focal loss volume)and GLV(global loss volume)were significantly higher in the affected eyes(both P<0.001).SCP VD was inversely correlated with FLV and GLV.Conclusions Silicone oil-related severe visual loss was associated with superficial retinal microvasculature damage and ganglion cell apoptosis.展开更多
AIM: To report the results of combined vitrectomy, lensectomy and silicone oil (SO) tamponade in treating primary rhegmatogenous retinal detachment (RRD) associated with choroidal detachment (CD). · METHODS: A re...AIM: To report the results of combined vitrectomy, lensectomy and silicone oil (SO) tamponade in treating primary rhegmatogenous retinal detachment (RRD) associated with choroidal detachment (CD). · METHODS: A retrospective, consecutive and case series study of 21 subjects with concurrent RRD associated with CD was conducted. All subjects underwent a standard three -port 20G pars plana vitrectomy (PPV) with lensectomy and silicone oil tamponade. Mean follow -up time was 8 months (rang from 4 to 19 months). The primary and final anatomic success rate, visual acuity and final intraocular pressure (IOP) were recorded and analyzed. ·RESULTS: Of 21 subjects, 8 were women and 13 were men. Age at presentation ranged from 22 to 75 years (mean 57.4 years). The presenting vision ranged from light perception to 0.15. The initial IOP ranged from 3mmHg to 12mmHg (mean 6.2mmHg). All eyes were phakic except one pseudophakic. No intraocular lens was implanted during the primary surgical intervention. Fifteen of 21 (71.4%) eyes had retina reattached after one operation. Six eyes had recurrent inferior retinal detachment due to proliferation. Five of them were successfully reattached after one or more additional operations. Mean IOP at final follow -up was 15.2mmHg (range from 8mmHg to 20mmHg). One case declined for further operation. The final reattachment rate was 95.2%. Visual acuity improved in 19 (90.5%) eyes, was unchanged in 1 (4.8%) eye and decreased in 1 (4.8%) eye.·CONCLUSION: Combination of vitrectomy, lensectomy and silicone tamponade is an effective method in treating RRD associated with CD, reducing the incidence of postoperative hypotony.展开更多
BACKGROUND Stent insertion can effective alleviate the symptoms of benign esophageal strictures(BES).Magnesium alloy stents are a good candidate because of biological safety,but show a poor corrosion resistance and a ...BACKGROUND Stent insertion can effective alleviate the symptoms of benign esophageal strictures(BES).Magnesium alloy stents are a good candidate because of biological safety,but show a poor corrosion resistance and a quick loss of mechanical support in vivo.AIM To test the therapeutic and adverse effects of a silicone-covered magnesium alloy biodegradable esophageal stent.METHODS Fifteen rabbits underwent silicone-covered biodegradable magnesium stent insertion into the benign esophageal stricture under fluoroscopic guidance(stent group).The wall reconstruction and tissue reaction of stenotic esophagus in the stent group were compared with those of six esophageal stricture models(control group).Esophagography was performed at 1,2,and 3 weeks.Four,six,and five rabbits in the stent group and two rabbits in the control groups were euthanized,respectively,at each time point for histological examination.RESULTS All stent insertions were well tolerated.The esophageal diameters at immediately,1,2 and 3 wk were 9.8±0.3 mm,9.7±0.7 mm,9.4±0.8 mm,and 9.2±0.5 mm,respectively(vs 4.9±0.3 mm before stent insertion;P<0.05).Magnesium stents migrated in eight rabbits[one at 1 wk(1/15),three at 2 wk(3/11),and four at 3 wk(4/5)].Esophageal wall remodeling(thinner epithelial and smooth muscle layers)was found significantly thinner in the stent group than in the control group(P<0.05).Esophageal injury and collagen deposition following stent insertion were similar and did not differ compared to rabbits with esophageal stricture and normal rabbits(P>0.05).CONCLUSION Esophageal silicone-covered biodegradable magnesium stent insertion is feasible for BES without causing severe injury or tissue reaction.Our study suggests that insertion of silicone-covered magnesium esophageal stent is a promising approach for treating BES.展开更多
The aim of this study is to report and analyze the factors related with earlier occurrence of silicone oil(SO) emulsification in patients underwent pars plana vitrectomy and SO injection in our hospital. We retrospect...The aim of this study is to report and analyze the factors related with earlier occurrence of silicone oil(SO) emulsification in patients underwent pars plana vitrectomy and SO injection in our hospital. We retrospectively reviewed consecutive case series undergone both SO injection and removal in our hospital, and 182 ones were eligible. Possible related independent factors included: macula status(on/off), concomitant phacoemulsification with the surgery of SO tamponading, concomitant status of proliferative vitreoretinopathy, combined surgery of retinotomy, time to have emulsification(<6 mo/≥6 mo after primary SO injection), route of SO injection(anterior/posterior), lens status(aphakic/pseudophakic/phakic), anesthesia(local/general), brands and type of SO, with/without episcleral cryotherapy, with/without hypertension, with/without diabetes, with/without intraoperative use of triamcinolone acetonide. The study revealed that brand and type of SO was the significant factor related with earlier emulsification of SO. Further study was warranted to find out the underlying causes.展开更多
AIM: To compare the success rate of monocanalicular versus pushed monocanalicular silicone intubation(PMCI)of the nasolacrimal duct for congenital nasolacrimal duct obstruction(CNLDO).METHODS: In a prospective randomi...AIM: To compare the success rate of monocanalicular versus pushed monocanalicular silicone intubation(PMCI)of the nasolacrimal duct for congenital nasolacrimal duct obstruction(CNLDO).METHODS: In a prospective randomized clinical trial 53 eyes of 49 patients with CNLDO underwent either monocanalicular silicone intubation(MCI)(n =28 eyes) or PMCI(n =25 eyes). All procedures were performed by 1oculoplastic surgeon. Treatment success was defined as the complete resolution of epiphora at 3mo after tube removal.RESULTS: The surgical outcome was assessed in 20 eyes with MCI and 20 eyes with PMCI. The mean age of treatment was 26.25 ±10.08mo(range, 13-49mo) for MCI and 26.85±12.25mo(range, 16-68mo) for PMCI. Treatment success was achieved in 18 of 20 eyes(90.0%) in the MCI group compared with 10 of 20 eyes(50%) in the PMCI group(P =0.01). In the PMCI group, the tube loss(30%)was greater than the MCI group(5%), however the differences between the 2 groups proved to be not significant(P =0.91).CONCLUSION: Our results indicate that MCI has higher success rate in CNLDO treatment compared with PMCI in this small series of patients.展开更多
Cloud point extraction (CPE) processes with two silicone surfactants, Dow Coming DC-190 and DC-193, were studied as preconcentration and treatment for the water polluted by three trace polycyclic aromatic hydrocarbo...Cloud point extraction (CPE) processes with two silicone surfactants, Dow Coming DC-190 and DC-193, were studied as preconcentration and treatment for the water polluted by three trace polycyclic aromatic hydrocarbons (PAHs): anthracene, phenanthrene and pyrene. For all cases, the volumes of surfactant-rich phase obtained by two silicone surfactants were very small, i.e. a lower water content in the surfactant-rich phase was obtained. For example, less than 3% of the initial solution was obtained in a 1% (by mass) surfactant solution, which was much smaller than that of TX-114 in the same surfactant concentration. And TX-114 is known as a high compact surfactant-rich phase among most nonionic surfactants, thus the comparison showed that an excellent enrichment was ensured in the analysis application by the CPE process with the silicone surfactants, and the lower water content obtained in the surfactant-rich phase is also important in the large scale water treatment. The influences of additives and phase separation methodology on the recovery of PAHs were discussed. Comparing with DC-193, DC-190 has a lower cloud point and a higher recovery (near 100%) of all the three PAHs in same surfactant concentration, which was required for application as a preconcentration process prior to HPLC system. However the DC-190 solution is hard to be phase separated only by heating, whereas DC-193 has a relative higher phase separating speed by heating, but a high cloud point (around 360K) limits its application. Due to the phase separation by heating is the only method of CPE suitable to the large scale water treatment, the mixtures of two silicone surfacrants solutions were investigated in this study. A solution containing 1% of mixed DC-190 and DC-193 (in the ratio of 90 : 10) removed anthracene, phenanthrene and pyrene near 100% with a relative low cloud point and quick phase separating speed.展开更多
A piston-cylinder apparatus was established to measure the solubility and diffusivity of air in dimethyl silicone oils and in hydraulic oils based on the PVT state equation of air and the solution of unsteady one-dime...A piston-cylinder apparatus was established to measure the solubility and diffusivity of air in dimethyl silicone oils and in hydraulic oils based on the PVT state equation of air and the solution of unsteady one-dimensional diffusion equation.The measured diffusivity-temperature relation can be well fitted by the Arrhenius equation for engineering applications.The correlation between the solute diffusivity D and solvent viscosity μ is examined.In terms of Eyring's activation theory,the activation in the air-silicone-oil diffusion process is quite different from that in the momentum transport of the silicone oil:the activation entropy of the former is positive while that of latter is negative.However,the activation enthalpies of the two processes are in the same order of magnitude,which leads to the observation that Dμ/T is roughly constant.展开更多
基金supported by the Science and Technology Research and Development Plan of the China State Railway Group Company Limited(No.Q2023J012).
文摘Purpose–The brake pipe system was an essential braking component of the railway freight trains,but the existing E-type sealing rings had problems such as insufficient low-temperature resistance,poor heat stability and short service life.To address these issues,low-phenyl silicone rubber was prepared and tested,and the finite element analysis and experimental studies on the sealing performance of its sealing rings were carried out.Design/methodology/approach–The low-temperature resistance and thermal stability of the prepared lowphenyl silicone rubber were studied using low-temperature tensile testing,differential scanning calorimetry,dynamic thermomechanical analysis and thermogravimetric analysis.The sealing performance of the lowphenyl silicone rubber sealing ring was studied by using finite element analysis software abaqus and experiments.Findings–The prepared low-phenyl silicone rubber sealing ring possessed excellent low-temperature resistance and thermal stability.According to the finite element analysis results,the finish of the flange sealing surface and groove outer edge should be ensured,and extrusion damage should be avoided.The sealing rings were more susceptible to damage in high compression ratio and/or low-temperature environments.When the sealing effect was ensured,a small compression ratio should be selected,and rubbers with hardness and elasticity less affected by temperature should be selected.The prepared low-phenyl silicone rubber sealing ring had zero leakage at both room temperature(RT)and�508C.Originality/value–The innovation of this study is that it provides valuable data and experience for the future development of the sealing rings used in the brake pipe flange joints of the railway freight cars in China.
基金Supported by the Shanghai Key Clinical Specialty,Shanghai Eye Disease Research Center(No.2022ZZ01003)the Science and Technology Commission of Shanghai(No.20DZ2270800).
文摘AIM:To evaluate the efficacy and safety of silicone oil(SO)as a corneal lubricant to improve visualization during vitrectomy.METHODS:Patients who underwent vitreoretinal surgery were divided into two groups.Group 1 was operated on with initial SO(Oxane 5700)as a corneal lubricant.Group 2 was operated on with initial lactated ringer’s solution(LRS)and then replaced with SO as required.Fundus clarity was scored during the surgery.Fluorescein staining was performed to determine the damage to corneal epithelium.RESULTS:Totally 114 eyes of 114 patients were included.Single SO use maintained a clear cornea and provided excellent visualization of surgical image.In group 1,the fundus clarity was grade 3 in 41/45 eyes and grade 2 in 4/45 eyes.In group 2,corneal edema frequently occurred after initial LRS use.The fundus clarity was grade 3 in 19/69 eyes,2 in 37/69 eyes and 1 in 13/69 eyes(P<0.05).SO was applied in 29 eyes of initial LRS use with subsequent corneal edema,which eliminated the corneal edema in 26 eyes.Corneal fluorescein staining score in group 1 was 0 in 28 eyes,1 in 11 eyes and 2 in 6 eyes,and 40,20 and 9,respectively,in group 2(all P>0.05).CONCLUSION:The use of SO as a corneal lubricant is effective and safe for preserving and improving corneal clarity and providing clear surgical field during vitrectomy.
基金Supported by National Natural Science Foundation of China(No.81700884)Scientific Research Foundation of National Health and Health Commission(No.WKJ-ZJ-2037)+1 种基金Zhejiang Public Welfare Technology Application Project(No.LGF21H120005)Science and Technology Project of Wenzhou(No.Y20190649).
文摘AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.
基金Supported by National Key R and D Program of China,No.2020YFC2008200.
文摘BACKGROUND Endophthalmitis occurring in silicone oil-filled eyes is a very rare occurrence,with reported incidence rates ranging between 0.07%and 0.039%.Traditional methods of management of infectious endophthalmitis include the removal of silicone oil,washout of the vitreous cavity,administration of intravitreal antibiotics,and reinjection of silicone oil.CASE SUMMARY Herein,we report the case of a 39-year-old man with unilateral endophthalmitis after pars plana vitrectomy and silicone oil tamponade.Intravitreal injections of full-dose antibiotics and anterior chamber washout were used to treat the patient.No signs of retinal toxicity were observed during the follow-up period.CONCLUSION Intravitreal full-dose antibiotic injections and anterior chamber washout are promising alternatives to traditional therapies for endophthalmitis in silicone oilfilled eyes.
基金National Natural Science Foundation of China,No.82160207Technology Plan of Jiangxi Provincial Health and Health Commission,No.202130156+1 种基金Young Scholar Project of the First Affiliated Hospital of Nanchang University,No.YFYPY202219Science and Key Projects of Jiangxi Youth Science Fund,No.20202ACBL216008.
文摘BACKGROUND We report a case of eye-penetrating injury in which a massive silicone oil migration into the patient’s subconjunctival space and orbit occurred after vitrectomy.CASE SUMMARY A 30-year-old male patient sought medical attention at Ganzhou People’s Hospital after experiencing pain and vision loss in his left eye due to a nail wound on December 9,2023.Diagnosis of penetrating injury caused by magnetic foreign body retention in the left eye and hospitalization for treatment.On December 9,2023,pars plana vitrectomy was performed on the left eye for intraocular foreign body removal,abnormal crystal extraction,retinal photocoagulation.Owing to the discovery of retinal detachment at the posterior pole during surgery,silicone oil was injected to fill the vitreous body,following which upper conjunctival bubble-like swelling was observed.Postoperative orbital computed tomography(CT)review indicated migration of silicone oil to the subconjunctival space and orbit through a self-permeable outlet.On December 18,2023,the patient sought treatment at the First Affiliated Hospital of Nanchang University,China.The patient presented with a pronounced foreign body sensation following left eye surgery.On December 20,2023,the foreign body was removed from the left eye frame and an intraocular examination was conducted.The posterior scleral tear had closed,leading to termination of the surgical procedure following supplementary laser treatment around the tear.The patient reported a significant reduction in ocular surface symptoms just one day after surgery.Furthermore,a notable decrease in the migration of silicone oil was observed in orbital CT scans.CONCLUSION The timing of silicone oil injection for an eye-penetrating injury should be carefully evaluated to avoid the possibility of silicone oil migration.
文摘Introduction: RRD (Rhegmatogenous Retinal Detachment) is a separation between the neuroepithelium and the pigment epithelium due to the passage of fluid through a retinal dehiscence. It constitutes a major ophthalmologic emergency. Its management is primarily surgical, either through external or internal approaches, with tamponade using gas or silicone oil. The purpose of this study was to report the various complications associated with the use of silicone oil in vitreoretinal surgery. Patients et methods: We conducted a retrospective, descriptive, and analytical study from October 1, 2020, to October 31, 2023, which included all patients who underwent surgery for RRD using three-port vitrectomy (3PV) with tamponade using 1000 centistoke silicone oil (Group 1) and 5000 centistoke silicone oil (Group 2). All patients underwent a complete ophthalmologic examination and were operated on by the same surgeon. Data analysis was performed using Excel software. Results: Overall, 31 patient files representing 33 eyes were collected, with a mean age of 48.83 years and a sex ratio of 4.16. Group 1 consisted of 16 eyes (48.48%), and Group 2 consisted of 17 eyes (51.51%). The different complications observed were cataracts in all phakic subjects, accounting for 57.57%;ocular hypertonia in 69.69% (27.27% in Group 1;42.42% in Group 2);anterior chamber silicone oil migration in 24.24% (9.09% in Group 1;15.15% in Group 2);recurrence of retinal detachment in 21.21% (6.06% in Group 1;15.15% in Group 2);and silicone oil emulsification in 24.24% (15.15% in Group 1;9.09% in Group 2). Additionally, there was one case of corneal degeneration in Group 1. Conclusion: Silicone oil is an effective tamponade agent used in the treatment of retinal detachments. Close patient follow-up is necessary due to the complications associated with its use, which can occur either early or late after surgery.
文摘Silicone is a kind of polymer material with high cross-linked structure,which is com-posed by Si-O-Si main chain.Due to the special molecular chain structure,silicone mate-rials are characterized by oxidation resistance,aging resistance,high and low temperature resistance and chemical corrosion resistance.Moreover,silicone materials have process-able properties,simple forming process,good mechanical property,non-toxic and pollution-free.Therefore,silicone has been widely concerned by researchers at home and abroad.In this paper,the main research progress and application directions of carbon-silicone composite at home and abroad in recent years are reviewed.
文摘AIM:To compare success rates and complications of Densiron 68 and 1000cSt silicone oil (SO) in the management of rhegmatogenous retinal detachment (RRD) with inferior breaks (IBs). METHODS:Totally 61 eyes of 61 consecutive patients with RRD with IBs were assigned to pars plana vitrectomy (PPV) with Densiron (n =31) or PPV with SO (n=30) in order of presentation. SO and Densiron removal was performed 3 months after initial surgery. Follow up visits were terminated 6 months after SO removal. ·RESULTS:With a single operation, the Densiron group showed 84% and SO 74% reattachment. With further surgery, both groups showed 90% reattachment. Complications such as cataract, raised intraocular pressure (IOP), inflammatory reaction, macular epiretinal membranes, and emulsification of SO were seen in both groups. CONCLUSION:Densiron and SO are found to have similar success rates and complications.
基金the Wenzhou Basic ScientificResearch Program (No.20211003).
文摘AIM:To investigate the safety and efficacy of sticky silicone oil(SSO)removal using a 22-gauge vein detained needle and inner limiting membrane(ILM)wrap-and-peel technique.METHODS:This retrospective consecutive case series reviewed the records of patients with a history of retinal detachment who had received silicone oil and perfluorocarbon liquid(PFCL)as intraocular tamponades.Patients were included in the analysis if they exhibited SSO remnants during silicone oil removal.The aspiration of most of the SSO remnants was performed by a 22-gauge vein detained needle.The small amounts of droplets adhered to the macula and epi-macular membrane were subsequently removed by the ILM warp-and-peel technique.The anatomical and functional outcomes,and postoperative complications were recorded.In vitro experiments were performed to simulate the formation of SSO remnants in four groups.RESULTS:Of 711 patients who underwent silicone oil removal during the study period,9 patients exhibited SSO remnants and underwent follow-up for at least 3mo.Seven eyes(78%)underwent the ILM wrap-and-peel technique to completely remove small droplets of SSO that were glued to the macula and epi-macular membrane.No obvious complications occurred.Postoperative optical coherence tomography revealed normal retinal structure in all patients.In vitro analyses showed that balanced salt solution and prolonged vibration(for 1wk)had the strongest effects on silicone oil and PFCL compound opacities.CONCLUSION:SSO remnants could be removed in an intact manner and without complications,using a vein detained needle-assisted and ILM wrap-and-peel technique.The findings suggest that PFCL and infusion fluid should be completely removed before silicone oil injection to prevent SSO formation.
基金Ministry of Science and Technology of China for Major State Basic Research Projects (2002AA322020)
文摘A silicone acrylate micro-emulsion of multipolymer was prepared by seed emulsion polymerization. The effects of polymerization process, emulsifier rate and amount, initiator rate and amount, polymerization temperature, functional monomers, titration time on performances of emulsion have been discussed in detail.
文摘Background: Silicone oil (SO) has been demonstrated with concrete efficacy and safety in the therapy of complex vitreoretinal diseases. SO is schemed to be cleared within several weeks or months after tamponade, but it’s inevitable for permanent or residual SO in a fraction of patients under extremely complicated clinical conditions. Here, we presented a case of silicone oil removal after 10 years, mainly to observe the disadvantages of long-term persistence. Case presentation: A 69-year-old female with pathologic myopia denied trauma history who had undergone pars plana vitrectomy (PPV), retinal reattachment, laser, and silicone oil tamponade in 2012 presented to our hospital with eye pain and headache, no light perception of her right eye for six months. The slit-lamp biomicroscopy examination for OD indicated evident conjunctival congestion, new blood vessels invasion to the limbus, foggy edema of corneal epithelium, folds of Descemet’s membrane and corneal endothelial edema. There were obvious emulsified silicone oil particles above the anterior chamber. Goldmann’s applanation tonometry test revealed the intraocular pressure was as high as 45/17mmHg. From ocular ultrasound, we saw that the vitreous cavity was filled with silicone oil in right eye;as for the left eye, it showed marked axial elongation and posterior scleral staphyloma. We were unable to obtain more information from fundus photography and macular optical coherence tomography (OCT) due to edema of the cornea. After the silicone oil was removed successfully from her vitreous cavity, although there was no improvement in the patient’s vision (no light perception), she was still satisfied with the relief from eye pain and headache benefited from the reduction of high intraocular pressure (Goldmann’s intraocular pressure decreased to 19/14mmHg). Conclusion: Patients after PPV should remove silicone oil in time to avoid corneal damage, intraocular hypertension, lens opacity and retinal damage induced by long-term silicone tamponade.
基金supported by Capital Medical University Affiliated Beijing Tongren Hospital Key Medical Development Plan[trzdyxzy201801].
文摘Objective The aim of this study was to investigate macular perfusion changes and ganglion cell complex(GCC)loss in patients with unexplained visual loss following vitrectomy and silicone oil(SO)tamponade,and to evaluate the correlation between retinal blood flow and GCC loss using optical coherence tomography angiography(OCTA)and optical coherence tomography(OCT).Methods This retrospective study included seven eyes(seven patients)with unexpected visual loss after vitrectomy and SO tamponade.OCTA was used to evaluate the alterations in retinal vessel density(VD)in the superficial capillary plexus(SCP),deep capillary plexus(DCP),and radial peripapillary capillary plexus(RPCP).OCT was used to measure the thickness of GCC and retinal nerve fiber layer(RNFL).Medical records of patients were reviewed.Results Quantitative analysis of OCTA images revealed a significant reduction in SCP VD in the affected eyes compared with the controls(all sections P<0.05).No difference was found in GCC thickness,but FLV(focal loss volume)and GLV(global loss volume)were significantly higher in the affected eyes(both P<0.001).SCP VD was inversely correlated with FLV and GLV.Conclusions Silicone oil-related severe visual loss was associated with superficial retinal microvasculature damage and ganglion cell apoptosis.
文摘AIM: To report the results of combined vitrectomy, lensectomy and silicone oil (SO) tamponade in treating primary rhegmatogenous retinal detachment (RRD) associated with choroidal detachment (CD). · METHODS: A retrospective, consecutive and case series study of 21 subjects with concurrent RRD associated with CD was conducted. All subjects underwent a standard three -port 20G pars plana vitrectomy (PPV) with lensectomy and silicone oil tamponade. Mean follow -up time was 8 months (rang from 4 to 19 months). The primary and final anatomic success rate, visual acuity and final intraocular pressure (IOP) were recorded and analyzed. ·RESULTS: Of 21 subjects, 8 were women and 13 were men. Age at presentation ranged from 22 to 75 years (mean 57.4 years). The presenting vision ranged from light perception to 0.15. The initial IOP ranged from 3mmHg to 12mmHg (mean 6.2mmHg). All eyes were phakic except one pseudophakic. No intraocular lens was implanted during the primary surgical intervention. Fifteen of 21 (71.4%) eyes had retina reattached after one operation. Six eyes had recurrent inferior retinal detachment due to proliferation. Five of them were successfully reattached after one or more additional operations. Mean IOP at final follow -up was 15.2mmHg (range from 8mmHg to 20mmHg). One case declined for further operation. The final reattachment rate was 95.2%. Visual acuity improved in 19 (90.5%) eyes, was unchanged in 1 (4.8%) eye and decreased in 1 (4.8%) eye.·CONCLUSION: Combination of vitrectomy, lensectomy and silicone tamponade is an effective method in treating RRD associated with CD, reducing the incidence of postoperative hypotony.
基金Supported by the National Natural Science Foundation of China,No.81371659,No.81571773,and No.81771943Shanghai Municipal Health and Family Planning Commission,No.201640191
文摘BACKGROUND Stent insertion can effective alleviate the symptoms of benign esophageal strictures(BES).Magnesium alloy stents are a good candidate because of biological safety,but show a poor corrosion resistance and a quick loss of mechanical support in vivo.AIM To test the therapeutic and adverse effects of a silicone-covered magnesium alloy biodegradable esophageal stent.METHODS Fifteen rabbits underwent silicone-covered biodegradable magnesium stent insertion into the benign esophageal stricture under fluoroscopic guidance(stent group).The wall reconstruction and tissue reaction of stenotic esophagus in the stent group were compared with those of six esophageal stricture models(control group).Esophagography was performed at 1,2,and 3 weeks.Four,six,and five rabbits in the stent group and two rabbits in the control groups were euthanized,respectively,at each time point for histological examination.RESULTS All stent insertions were well tolerated.The esophageal diameters at immediately,1,2 and 3 wk were 9.8±0.3 mm,9.7±0.7 mm,9.4±0.8 mm,and 9.2±0.5 mm,respectively(vs 4.9±0.3 mm before stent insertion;P<0.05).Magnesium stents migrated in eight rabbits[one at 1 wk(1/15),three at 2 wk(3/11),and four at 3 wk(4/5)].Esophageal wall remodeling(thinner epithelial and smooth muscle layers)was found significantly thinner in the stent group than in the control group(P<0.05).Esophageal injury and collagen deposition following stent insertion were similar and did not differ compared to rabbits with esophageal stricture and normal rabbits(P>0.05).CONCLUSION Esophageal silicone-covered biodegradable magnesium stent insertion is feasible for BES without causing severe injury or tissue reaction.Our study suggests that insertion of silicone-covered magnesium esophageal stent is a promising approach for treating BES.
文摘The aim of this study is to report and analyze the factors related with earlier occurrence of silicone oil(SO) emulsification in patients underwent pars plana vitrectomy and SO injection in our hospital. We retrospectively reviewed consecutive case series undergone both SO injection and removal in our hospital, and 182 ones were eligible. Possible related independent factors included: macula status(on/off), concomitant phacoemulsification with the surgery of SO tamponading, concomitant status of proliferative vitreoretinopathy, combined surgery of retinotomy, time to have emulsification(<6 mo/≥6 mo after primary SO injection), route of SO injection(anterior/posterior), lens status(aphakic/pseudophakic/phakic), anesthesia(local/general), brands and type of SO, with/without episcleral cryotherapy, with/without hypertension, with/without diabetes, with/without intraoperative use of triamcinolone acetonide. The study revealed that brand and type of SO was the significant factor related with earlier emulsification of SO. Further study was warranted to find out the underlying causes.
文摘AIM: To compare the success rate of monocanalicular versus pushed monocanalicular silicone intubation(PMCI)of the nasolacrimal duct for congenital nasolacrimal duct obstruction(CNLDO).METHODS: In a prospective randomized clinical trial 53 eyes of 49 patients with CNLDO underwent either monocanalicular silicone intubation(MCI)(n =28 eyes) or PMCI(n =25 eyes). All procedures were performed by 1oculoplastic surgeon. Treatment success was defined as the complete resolution of epiphora at 3mo after tube removal.RESULTS: The surgical outcome was assessed in 20 eyes with MCI and 20 eyes with PMCI. The mean age of treatment was 26.25 ±10.08mo(range, 13-49mo) for MCI and 26.85±12.25mo(range, 16-68mo) for PMCI. Treatment success was achieved in 18 of 20 eyes(90.0%) in the MCI group compared with 10 of 20 eyes(50%) in the PMCI group(P =0.01). In the PMCI group, the tube loss(30%)was greater than the MCI group(5%), however the differences between the 2 groups proved to be not significant(P =0.91).CONCLUSION: Our results indicate that MCI has higher success rate in CNLDO treatment compared with PMCI in this small series of patients.
文摘Cloud point extraction (CPE) processes with two silicone surfactants, Dow Coming DC-190 and DC-193, were studied as preconcentration and treatment for the water polluted by three trace polycyclic aromatic hydrocarbons (PAHs): anthracene, phenanthrene and pyrene. For all cases, the volumes of surfactant-rich phase obtained by two silicone surfactants were very small, i.e. a lower water content in the surfactant-rich phase was obtained. For example, less than 3% of the initial solution was obtained in a 1% (by mass) surfactant solution, which was much smaller than that of TX-114 in the same surfactant concentration. And TX-114 is known as a high compact surfactant-rich phase among most nonionic surfactants, thus the comparison showed that an excellent enrichment was ensured in the analysis application by the CPE process with the silicone surfactants, and the lower water content obtained in the surfactant-rich phase is also important in the large scale water treatment. The influences of additives and phase separation methodology on the recovery of PAHs were discussed. Comparing with DC-193, DC-190 has a lower cloud point and a higher recovery (near 100%) of all the three PAHs in same surfactant concentration, which was required for application as a preconcentration process prior to HPLC system. However the DC-190 solution is hard to be phase separated only by heating, whereas DC-193 has a relative higher phase separating speed by heating, but a high cloud point (around 360K) limits its application. Due to the phase separation by heating is the only method of CPE suitable to the large scale water treatment, the mixtures of two silicone surfacrants solutions were investigated in this study. A solution containing 1% of mixed DC-190 and DC-193 (in the ratio of 90 : 10) removed anthracene, phenanthrene and pyrene near 100% with a relative low cloud point and quick phase separating speed.
基金Supported by the National Natural Science Foundation of China (50675202)
文摘A piston-cylinder apparatus was established to measure the solubility and diffusivity of air in dimethyl silicone oils and in hydraulic oils based on the PVT state equation of air and the solution of unsteady one-dimensional diffusion equation.The measured diffusivity-temperature relation can be well fitted by the Arrhenius equation for engineering applications.The correlation between the solute diffusivity D and solvent viscosity μ is examined.In terms of Eyring's activation theory,the activation in the air-silicone-oil diffusion process is quite different from that in the momentum transport of the silicone oil:the activation entropy of the former is positive while that of latter is negative.However,the activation enthalpies of the two processes are in the same order of magnitude,which leads to the observation that Dμ/T is roughly constant.