期刊文献+
共找到48,219篇文章
< 1 2 250 >
每页显示 20 50 100
Multi-Scale Dilated Convolution Network for SPECT-MPI Cardiovascular Disease Classification with Adaptive Denoising and Attenuation Correction
1
作者 A.Robert Singh Suganya Athisayamani +1 位作者 Gyanendra Prasad Joshi Bhanu Shrestha 《Computer Modeling in Engineering & Sciences》 SCIE EI 2025年第1期299-327,共29页
Myocardial perfusion imaging(MPI),which uses single-photon emission computed tomography(SPECT),is a well-known estimating tool for medical diagnosis,employing the classification of images to show situations in coronar... Myocardial perfusion imaging(MPI),which uses single-photon emission computed tomography(SPECT),is a well-known estimating tool for medical diagnosis,employing the classification of images to show situations in coronary artery disease(CAD).The automatic classification of SPECT images for different techniques has achieved near-optimal accuracy when using convolutional neural networks(CNNs).This paper uses a SPECT classification framework with three steps:1)Image denoising,2)Attenuation correction,and 3)Image classification.Image denoising is done by a U-Net architecture that ensures effective image denoising.Attenuation correction is implemented by a convolution neural network model that can remove the attenuation that affects the feature extraction process of classification.Finally,a novel multi-scale diluted convolution(MSDC)network is proposed.It merges the features extracted in different scales and makes the model learn the features more efficiently.Three scales of filters with size 3×3 are used to extract features.All three steps are compared with state-of-the-art methods.The proposed denoising architecture ensures a high-quality image with the highest peak signal-to-noise ratio(PSNR)value of 39.7.The proposed classification method is compared with the five different CNN models,and the proposed method ensures better classification with an accuracy of 96%,precision of 87%,sensitivity of 87%,specificity of 89%,and F1-score of 87%.To demonstrate the importance of preprocessing,the classification model was analyzed without denoising and attenuation correction. 展开更多
关键词 SPECT-MPI CAD MSDC DENOISING attenuation correction classification
在线阅读 下载PDF
Correction:Passive neutron multiplicity device for 240Pu measurement based on FPGA
2
作者 Yan Zhang Hao-Ran Zhang +6 位作者 Ren-Bo Wang Ming-Yu Li Rui Chen Hai-Tao Wang Xiang-Ting Meng Shu-Min Zhou Bin Tang 《Nuclear Science and Techniques》 2025年第2期155-155,共1页
Correction to:Nuclear Science and Techniques(2024)35:162 https://doi.org/10.1007/s41365-024-01514-1 In this article,the citation information for Figures 6 and 7 was published incorrectly.The correct citations should r... Correction to:Nuclear Science and Techniques(2024)35:162 https://doi.org/10.1007/s41365-024-01514-1 In this article,the citation information for Figures 6 and 7 was published incorrectly.The correct citations should read as follows:In the sentence beginning‘the curve of Eq.17 is plotted…..’in this article,the text‘as shown in Fig.7a’should have read‘as shown in Fig.6a’. 展开更多
关键词 MULTIPLICITY CITATION correction
在线阅读 下载PDF
Correction:A novel method for simultaneous measurement of ^(222)Rn and ^(220)Rn progeny concentrations measured by an alpha spectrometer
3
作者 Zhong-Kai Fan Jia-Le Sun +5 位作者 Hao-Xuan Li Xiang-Ming Cai Hui Yang Shou-Kang Qiu Yan-Liang Tan Jian Shan 《Nuclear Science and Techniques》 2025年第2期157-157,共1页
Correction to:Nuclear Science and Techniques(2024)36:8 https://doi.org/10.1007/s41365-024-01570-7 In this article the affiliation details for Author Jian Shan were incorrectly given as‘College of Physics and Electron... Correction to:Nuclear Science and Techniques(2024)36:8 https://doi.org/10.1007/s41365-024-01570-7 In this article the affiliation details for Author Jian Shan were incorrectly given as‘College of Physics and Electronic Engi-neering,Hengyang Normal University,Hengyang 421008,China’but should have been‘School of Nuclear Science and Technology,University of South China,Hengyang 421001,China’.The original article has been corrected. 展开更多
关键词 DETAILS SIMULTANEOUS corrected
在线阅读 下载PDF
Author Correction: X-ray irradiation selectively kills thymocytes of different stages and impairs the maturation of donor-derived CD4+CD8+ thymocytes in recipient thymus
4
作者 Jinbo Li Hongquan Cai +2 位作者 Jianliang Jin Qian Wang Dengshun Miao 《Journal of Biomedical Research》 2025年第2期213-213,共1页
Correction to:Journal of Biomedical Research https://doi.org/10.7555/JBR.26.20120003,published on June 8,2012.We sincerely apologize for the misuse of images in Fig.4 of our article.Specifically,the image in Fig.4D,de... Correction to:Journal of Biomedical Research https://doi.org/10.7555/JBR.26.20120003,published on June 8,2012.We sincerely apologize for the misuse of images in Fig.4 of our article.Specifically,the image in Fig.4D,depicting immunohistochemistry staining for Jagged1 expression,was partially incorrect because of our oversight.Upon reviewing the laboratory records,we have successfully located the original images from 12 years ago.We are now providing the corrected version of Fig.4D below.This correction does not alter the conclusions as originally reported. 展开更多
关键词 correction image originally
在线阅读 下载PDF
AI-based Correction of Wave Forecasts Using the Transformer-enhanced UNet Model
5
作者 Yanzhao CAO Shouwen ZHANG +2 位作者 Guannan LV Mengchao YU Bo AI 《Advances in Atmospheric Sciences》 2025年第1期221-231,共11页
Grid forecasting can be used to effectively enhance the spatial and temporal density of forecast products,thereby improving the capability of short-term marine disaster forecasting and warnings in terms of proximity.T... Grid forecasting can be used to effectively enhance the spatial and temporal density of forecast products,thereby improving the capability of short-term marine disaster forecasting and warnings in terms of proximity.The traditional method that relies on forecasters'subjective correction of station observation data for forecasting has been unable to meet the practical needs of refined forecasting.To address this problem,this paper proposes a Transformer-enhanced UNet(TransUNet)model for wave forecast AI correction,which fuses wind and wave information.The Transformer structure is integrated into the encoder of the UNet model,and instead of using the traditional upsampling method,the dual-sampling module is employed in the decoder to enhance the feature extraction capability.This paper compares the TransUNet model with the traditional UNet model using wind speed forecast data,wave height forecast data,and significant wave height reanalysis data provided by ECMWF.The experimental results indicate that the TransUNet model yields smaller root-meansquare errors,mean errors,and standard deviations of the corrected results for the next 24-h forecasts than does the UNet model.Specifically,the root-mean-square error decreased by more than 21.55%compared to its precorrection value.According to the statistical analysis,87.81%of the corrected wave height errors for the next 24-h forecast were within±0.2m,with only 4.56%falling beyond±0.3 m.This model effectively limits the error range and enhances the ability to forecast wave heights. 展开更多
关键词 TransUNet TRANSFORMER wave forecasting bias correction
在线阅读 下载PDF
Improving the Seasonal Forecast of Summer Precipitation in Southeastern China Using a CycleGAN-based Deep Learning Bias Correction Method
6
作者 Song YANG Fenghua LING +1 位作者 Jing-Jia LUO Lei BAI 《Advances in Atmospheric Sciences》 2025年第1期26-35,共10页
Accurate seasonal precipitation forecasts,especially for extreme events,are crucial to preventing meteorological hazards and their potential impacts on national development,social activity,and security.However,the int... Accurate seasonal precipitation forecasts,especially for extreme events,are crucial to preventing meteorological hazards and their potential impacts on national development,social activity,and security.However,the intensity of summer precipitation is often largely underestimated in many current dynamic models.This study uses a deep learning method called Cycle-Consistent Generative Adversarial Networks(CycleGAN)to improve the seasonal forecasts for June-JulyAugust precipitation in southeastern China by the Nanjing University of Information Science and Technology Climate Forecast System(NUIST-CFS 1.0).The results suggest that the CycleGAN-based model significantly improves the accuracy in predicting the spatiotemporal distribution of summer precipitation compared to the traditional quantile mapping(QM)method.Using the unpaired bias-correction model,we can also obtain advanced forecasts of the frequency,intensity,and duration of extreme precipitation events over the dynamic model predictions.This study expands the potential applications of deep learning models toward improving seasonal precipitation forecasts. 展开更多
关键词 bias correction CycleGAN QM NUIST-CFS 1.0 extreme precipitation
在线阅读 下载PDF
Global receptive field transformer decoder method on quantum surface code data and syndrome error correction
7
作者 Ao-Qing Li Ce-Wen Tian +2 位作者 Xiao-Xuan Xu Hong-Yang Ma Jun-Qing Liang 《Chinese Physics B》 2025年第3期267-276,共10页
Quantum computing has the potential to solve complex problems that are inefficiently handled by classical computation.However,the high sensitivity of qubits to environmental interference and the high error rates in cu... Quantum computing has the potential to solve complex problems that are inefficiently handled by classical computation.However,the high sensitivity of qubits to environmental interference and the high error rates in current quantum devices exceed the error correction thresholds required for effective algorithm execution.Therefore,quantum error correction technology is crucial to achieving reliable quantum computing.In this work,we study a topological surface code with a two-dimensional lattice structure that protects quantum information by introducing redundancy across multiple qubits and using syndrome qubits to detect and correct errors.However,errors can occur not only in data qubits but also in syndrome qubits,and different types of errors may generate the same syndromes,complicating the decoding task and creating a need for more efficient decoding methods.To address this challenge,we used a transformer decoder based on an attention mechanism.By mapping the surface code lattice,the decoder performs a self-attention process on all input syndromes,thereby obtaining a global receptive field.The performance of the decoder was evaluated under a phenomenological error model.Numerical results demonstrate that the decoder achieved a decoding accuracy of 93.8%.Additionally,we obtained decoding thresholds of 5%and 6.05%at maximum code distances of 7 and 9,respectively.These results indicate that the decoder used demonstrates a certain capability in correcting noise errors in surface codes. 展开更多
关键词 quantum error correction surface code transformer decoder
在线阅读 下载PDF
Correction to:Impact of comorbid subthreshold depressive symptoms on cancer-related fatigue and complications in adults with leukemia
8
作者 Yue-Xian Liu Juan Wang 《World Journal of Psychiatry》 2025年第3期361-362,共2页
Correction to"Liu YX,Wang J.Impact of comorbid subthreshold depressive symptoms on cancer-related fatigue and complications in adults with leukemia.World J Psychiatry 2024;14(7):1009-1016[PMID:39050202 DOI:10.549... Correction to"Liu YX,Wang J.Impact of comorbid subthreshold depressive symptoms on cancer-related fatigue and complications in adults with leukemia.World J Psychiatry 2024;14(7):1009-1016[PMID:39050202 DOI:10.5498/wjp.v14.i7.1009]".In the methods section of this article's abstract needs to be corrected. 展开更多
关键词 World Journal of Psychiatry correction
在线阅读 下载PDF
Correction to:Assessing recent recurrence after hepatectomy for hepatitis B-related hepatocellular carcinoma by a predictive model based on sarcopenia
9
作者 Hong Peng Si-Yi Lei Xin-Hua Luo 《World Journal of Gastroenterology》 2025年第6期136-138,共3页
Correction to“Assessing recent recurrence after hepatectomy for hepatitis Brelated hepatocellular carcinoma by a predictive model based on sarcopenia.World J Gastroenterol 2024;30(12):1727-1738[PMID:38617742 DOI:10.3... Correction to“Assessing recent recurrence after hepatectomy for hepatitis Brelated hepatocellular carcinoma by a predictive model based on sarcopenia.World J Gastroenterol 2024;30(12):1727-1738[PMID:38617742 DOI:10.3748/wjg.v30.i12.1727]”.In this article,figure 1 needs to be corrected. 展开更多
关键词 World Journal of Gastroenterology correction
在线阅读 下载PDF
Fusion of Time-Frequency Features in Contrastive Learning for Shipboard Wind Speed Correction
10
作者 SONG Jian HUANG Meng +3 位作者 LI Xiang ZHANG Zhenqiang WANG Chunxiao ZHAO Zhigang 《Journal of Ocean University of China》 2025年第2期377-386,共10页
Accurate wind speed measurements on maritime vessels are crucial for weather forecasting,sea state prediction,and safe navigation.However,vessel motion and challenging environmental conditions often affect measurement... Accurate wind speed measurements on maritime vessels are crucial for weather forecasting,sea state prediction,and safe navigation.However,vessel motion and challenging environmental conditions often affect measurement precision.To address this issue,this study proposes an innovative framework for correcting and predicting shipborne wind speed.By integrating a main network with a momentum updating network,the proposed framework effectively extracts features from the time and frequency domains,thereby allowing for precise adjustments and predictions of shipborne wind speed data.Validation using real sensor data collected at the Qingdao Oceanographic Institute demonstrates that the proposed method outperforms existing approaches in single-and multi-step predictions compared to existing methods,achieving higher accuracy in wind speed forecasting.The proposed innovative approach offers a promising direction for future validation in more realistic maritime onboard scenarios. 展开更多
关键词 time series prediction wind speed correction comparative learning shipborne sensor
在线阅读 下载PDF
Enhanced Bragg Filter:A New Drift Correction Method for Low-dose High-Resolution STEM Images
11
作者 WANG Yujiao ZHOU Jinfei +3 位作者 LIU Dong LIU Lingmei LI Xiao ZHANG Daliang 《Chemical Research in Chinese Universities》 2025年第2期343-350,共8页
High-angle annular dark-field scanning TEM(HAADF-STEM)images play a critical role in the structural characterization of chemical materials.However,drift correction is a critical challenge in imaging beam-sensitive mat... High-angle annular dark-field scanning TEM(HAADF-STEM)images play a critical role in the structural characterization of chemical materials.However,drift correction is a critical challenge in imaging beam-sensitive materials,where sample motion and signal-to-noise ratio(SNR)hinder high-resolution image reconstruction.In this study,we propose an enhanced Bragg filter(EBF)method for robust drift correction and high-resolution reconstruction of HAADF-STEM images.The EBF method involves the semi-manual selection of reflection spots to extract periodic lattice features,which significantly enhance the SNR and preserve periodicity in low-dose images.We demonstrate the superior performance of the method by comparing it with conventional low-pass and band-pass filters.The effectiveness of the EBF method is validated on ZSM-5 zeolite crystals,achieving a spatial resolution of 1.25Å(1Å=0.1 nm)and enabling precise tracking of structural evolution under electron beam exposure.Furthermore,we apply the EBF method for super-resolution imaging of ZSM-5 at low magnification,enriching structural details without compromising the field of view.This study presents a robust solution for imaging beam-sensitive materials and advancing low-dose electron microscopy techniques. 展开更多
关键词 STEM image series Drift correction Enhanced Bragg filter Beam-sensitive material Super-resolution
原文传递
LACC-RCE:A Local Adaptive Color Correction and Rayleigh-Based Contrast Enhancement Method for Underwater Image Enhancement
12
作者 Tiancheng Liu 《Journal of Electronic Research and Application》 2025年第2期140-149,共10页
Underwater images are inherently degraded by color distortion,contrast reduction,and uneven brightness,primarily due to light absorption and scattering in water.To mitigate these challenges,a novel enhancement approac... Underwater images are inherently degraded by color distortion,contrast reduction,and uneven brightness,primarily due to light absorption and scattering in water.To mitigate these challenges,a novel enhancement approach is proposed,integrating Local Adaptive Color Correction(LACC)with contrast enhancement based on adaptive Rayleigh distribution stretching and CLAHE(LACC-RCE).Conventional color correction methods predominantly employ global adjustment strategies,which are often inadequate for handling spatially varying color distortions.In contrast,the proposed LACC method incorporates local color analysis,tone-weighted control,and spatially adaptive adjustments,allowing for region-specific color correction.This approach effectively enhances color fidelity and perceptual naturalness,addressing the limitations of global correction techniques.For contrast enhancement,the proposed method leverages the global mapping characteristics of the Rayleigh distribution to improve overall contrast,while CLAHE is employed to adaptively enhance local regions.A weighted fusion strategy is then applied to synthesize high-quality underwater images.Experimental results indicate that LACC-RCE surpasses conventional methods in color restoration,contrast optimization,and detail preservation,thereby enhancing the visual quality of underwater images.This improvement facilitates more reliable inputs for underwater object detection and recognition tasks. 展开更多
关键词 UNDERWATER Image enhancement Local adaptive color correction Rayleigh distribution stretching Contrast enhancement
在线阅读 下载PDF
Improving atmospheric pressure vertical correction model using Gaussian function
13
作者 Baoshuang Zhang Junyu Li +6 位作者 Lilong Liu Yibin Yao Liangke Huang Chao Ren Hongchang He Tengxu Zhang Yuxin Wang 《Geodesy and Geodynamics》 2025年第1期67-74,共8页
The Zenith Hydrostatic Delay(ZHD)is essential for high-precision Global Navigation Satellite System(GNSS)and Very Long Baseline Interferometry(VLBI)data processing.Accurate estimation of ZHD relies on in situ atmosphe... The Zenith Hydrostatic Delay(ZHD)is essential for high-precision Global Navigation Satellite System(GNSS)and Very Long Baseline Interferometry(VLBI)data processing.Accurate estimation of ZHD relies on in situ atmospheric pressure,which is primarily variable in the vertical direction.Current atmospheric pressure is either site-specific or has limited spatial coverage,necessitating vertical corrections for broader applicability.This study introduces a model that uses a Gaussian function for the vertical correction of atmospheric pressure when in situ meteorological observations are unavailable.Validation with the fifth-generation European Centre for Medium-Range Weather Forecasts reanalysis(ERA5)reveals an average Bias and RMS for the new model of 0.31 h Pa and 2.96 h Pa,respectively.This corresponds to improvements of 37.5%and 80.3%in terms of RMS compared to two commonly used models(T0and Tvmodels)that require in situ meteorological observations,respectively.Additional validation with radiosonde data shows an average Bias and RMS of 1.85 h Pa and 4.87 h Pa,corresponding to the improvement of 42.8%and 71.1%in RMS compared with T0and Tv models,respectively.These accuracies are sufficient for calculating ZHD to an accuracy of 1 mm by performing atmospheric pressure vertical correction.The new model can correct atmospheric pressure from meteorological stations or numerical weather forecasts to different heights of the troposphere. 展开更多
关键词 ATMOSPHERIC pressure Vertical correction Zenith hydrostatic delay(ZHD) Gauss function ERA5
在线阅读 下载PDF
Magnetic resonance imaging bias field correction improves tumor prognostic evaluation after transcatheter arterial chemoembolization for liver cancer
14
作者 Ke Liu Jun-Biao Li +1 位作者 Yong Wang Yan Li 《World Journal of Gastrointestinal Surgery》 2025年第4期207-220,共14页
BACKGROUND Transcatheter arterial chemoembolization(TACE)is a key treatment approach for advanced invasive liver cancer(infiltrative hepatocellular carcinoma).However,its therapeutic response can be difficult to evalu... BACKGROUND Transcatheter arterial chemoembolization(TACE)is a key treatment approach for advanced invasive liver cancer(infiltrative hepatocellular carcinoma).However,its therapeutic response can be difficult to evaluate accurately using conventional two-dimensional imaging criteria due to the tumor’s diffuse and multifocal growth pattern.Volumetric imaging,especially enhanced tumor volume(ETV),offers a more comprehensive assessment.Nonetheless,bias field inhomogeneity in magnetic resonance imaging(MRI)poses challenges,potentially skewing volumetric measurements and undermining prognostic evaluation.AIM To investigate whether MRI bias field correction enhances the accuracy of volumetric assessment of infiltrative hepatocellular carcinoma treated with TACE,and to analyze how this improved measurement impacts prognostic prediction.METHODS We retrospectively collected data from 105 patients with invasive liver cancer who underwent TACE treatment at the Affiliated Hospital of Xuzhou Medical University from January 2020 to January 2024.The improved N4 bias field correction algorithm was applied to process MRI images,and the ETV before and after treatment was calculated.The ETV measurements before and after correction were compared,and their relationship with patient prognosis was analyzed.A Cox proportional hazards model was used to evaluate prognostic factors,with Martingale residual analysis determining the optimal cutoff value,followed by survival analysis.RESULTS Bias field correction significantly affected ETV measurements,with the corrected baseline ETV mean(505.235 cm³)being significantly lower than before correction(825.632 cm³,P<0.001).Cox analysis showed that the hazard ratio(HR)for corrected baseline ETV(HR=1.165,95%CI:1.069-1.268)was higher than before correction(HR=1.063,95%CI:1.031-1.095).Using 412 cm³as the cutoff,the group with baseline ETV<415 cm³had a longer median survival time compared to the≥415 cm³group(18.523 months vs 8.926 months,P<0.001).The group with an ETV reduction rate≥41%had better prognosis than the<41%group(17.862 months vs 9.235 months,P=0.006).Multivariate analysis confirmed that ETV reduction rate(HR=0.412,P<0.001),Child-Pugh classification(HR=0.298,P<0.001),and Barcelona Clinic Liver Cancer stage(HR=0.578,P=0.045)were independent prognostic factors.CONCLUSION Volume imaging based on MRI bias field correction can improve the accuracy of evaluating the efficacy of TACE treatment for invasive liver cancer.The corrected ETV and its reduction rate can serve as independent indicators for predicting patient prognosis,providing important reference for developing individualized treatment strategies. 展开更多
关键词 Invasive liver cancer Transcatheter arterial chemoembolization Magnetic resonance imaging Bias field correction Volume imaging
在线阅读 下载PDF
Author correction to“Generation ofαGal-enhanced bifunctional tumor vaccine”[Acta Pharm Sin B 12(2022)3177-3186]
15
作者 Jian He Yu Huo +15 位作者 Zhikun Zhang Yiqun Luo Xiuli Liu Qiaoying Chen Pan Wu Wei Shi Tao Wu Chao Tang Huixue Wang Lan Li Xiyu Liu Yong Huang Yongxiang Zhao Lu Gan Bing Wang Liping Zhong 《Acta Pharmaceutica Sinica B》 2025年第2期1207-1207,共1页
The authors regret Fig.5C in the published article contained an incorrect image.Specifically,the image for the MHCC97H(pLVX-Puro)/DC group was mistakenly used during copying and pasting in the process of assembling th... The authors regret Fig.5C in the published article contained an incorrect image.Specifically,the image for the MHCC97H(pLVX-Puro)/DC group was mistakenly used during copying and pasting in the process of assembling the figure.This correction has no influence on the readers'understanding of the article.The original data of the figures have been provided to the Editorial Office,and the corresponding authors or the Editorial Office can be contacted for original data access. 展开更多
关键词 generation figure correction copying pasting bifunctional tumor vaccine mhcc h plvx puro dc group original data access GAL
原文传递
Correction:Nanomaterial-Based Repurposing of Macrophage Metabolism and Its Applications 被引量:1
16
作者 Tingting Meng Danfeng He +7 位作者 Zhuolei Han Rong Shi Yuhan Wang Bibo Ren Cheng Zhang Zhengwei Mao Gaoxing Luo Jun Deng 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第12期357-357,共1页
Following publication of the original article[1],the authors reported an error in the last author’s name,it was mistakenly written as“Jun Den”.The correct author’s name“Jun Deng”has been updated in this Correction.
关键词 MISTAKE correct correction
在线阅读 下载PDF
The application of the strip-shaped cymba conchae orthosis in the nonsurgical correction of complex auricular deformity 被引量:1
17
作者 Huijuan Xu Shaoguang Ding +6 位作者 Fei Zhang Zhifeng Zhang Xiangyu Chen Mingyang Li Haitao Yang Fugen Han Hongjian Liu 《Journal of Otology》 CAS CSCD 2024年第1期24-29,共6页
Objective: This study aims to evaluate the efficacy and safety of using a strip-shaped cymba conchae orthosis for the nonsurgical correction of complex auricular deformities. Methods: Clinical data were collected from... Objective: This study aims to evaluate the efficacy and safety of using a strip-shaped cymba conchae orthosis for the nonsurgical correction of complex auricular deformities. Methods: Clinical data were collected from 2020 to 2021 for 6 patients who underwent correction using a stripshaped cymba conchae orthosis. The indications, corrective effects, and complications associated with use of the orthosis were analyzed. Results: There were four indications for treatment: cryptotia with helix adhesion;cryptotia with grade I microtia;cryptotia with excessive helix thickness;and auricular deformity beyond the treatment time window(≥6 months). Excellent corrective effects were observed in all 6 patients. Complications occurred in one patient, who recovered after symptomatic treatment. Conclusion: The use of a strip-shaped cymba conchae orthosis alone or combined with a U-shaped helix orthosis presents a feasible approach for correcting complex auricular deformities or deformities beyond the treatment time window in pediatric patients. 展开更多
关键词 Cymba conchae Auricular deformity Cryptotia Nonsurgical correction ORTHOSIS
在线阅读 下载PDF
Adaptation analysis and fusion correction method of CMIP6 precipitation simulation data on the Qinghai-Tibetan Plateau
18
作者 PENG Hao QIN Dahui +3 位作者 WANG Zegen ZHANG Menghan YANG Yanmei YONG Zhiwei 《Journal of Mountain Science》 SCIE CSCD 2024年第2期555-573,共19页
In order to obtain more accurate precipitation data and better simulate the precipitation on the Tibetan Plateau,the simulation capability of 14 Coupled Model Intercomparison Project Phase 6(CMIP6)models of historical... In order to obtain more accurate precipitation data and better simulate the precipitation on the Tibetan Plateau,the simulation capability of 14 Coupled Model Intercomparison Project Phase 6(CMIP6)models of historical precipitation(1982-2014)on the Qinghai-Tibetan Plateau was evaluated in this study.Results indicate that all models exhibit an overestimation of precipitation through the analysis of the Taylor index,temporal and spatial statistical parameters.To correct the overestimation,a fusion correction method combining the Backpropagation Neural Network Correction(BP)and Quantum Mapping(QM)correction,named BQ method,was proposed.With this method,the historical precipitation of each model was corrected in space and time,respectively.The correction results were then analyzed in time,space,and analysis of variance(ANOVA)with those corrected by the BP and QM methods,respectively.Finally,the fusion correction method results for each model were compared with the Climatic Research Unit(CRU)data for significance analysis to obtain the trends of precipitation increase and decrease for each model.The results show that the IPSL-CM6A-LR model is relatively good in simulating historical precipitation on the Qinghai-Tibetan Plateau(R=0.7,RSME=0.15)among the uncorrected data.In terms of time,the total precipitation corrected by the fusion method has the same interannual trend and the closest precipitation values to the CRU data;In terms of space,the annual average precipitation corrected by the fusion method has the smallest difference with the CRU data,and the total historical annual average precipitation is not significantly different from the CRU data,which is better than BP and QM.Therefore,the correction effect of the fusion method on the historical precipitation of each model is better than that of the QM and BP methods.The precipitation in the central and northeastern parts of the plateau shows a significant increasing trend.The correlation coefficients between monthly precipitation and site-detected precipitation for all models after BQ correction exceed 0.8. 展开更多
关键词 GCM CMIP6 Precipitation correction BP-QM fusion correction Spatio-temporal characteristics
在线阅读 下载PDF
Correction: Surface Patterning of Metal ZincElectrode with an In-Region Zincophilic Interfacefor High-Rate and Long-Cycle-Life Zinc MetalAnode
19
作者 Tian Wang Qiao Xi +8 位作者 Kai Yao Yuhang Liu Hao Fu Venkata Siva Kavarthapu Jun Kyu Lee Shaocong Tang Dina Fattakhova-Rohlfing Wei Ai Jae Su Yu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第7期456-457,共2页
Correction to:Nano-Micro Letters(2024)16:112 https://doi.org/10.1007/s40820-024-01327-2 In the supplementary information the following corrections have been carried out:1.Institute of Energy and Climate Research,Mater... Correction to:Nano-Micro Letters(2024)16:112 https://doi.org/10.1007/s40820-024-01327-2 In the supplementary information the following corrections have been carried out:1.Institute of Energy and Climate Research,Materials Synthesis and Processing,Forschungszentrum Jülich GmbH,52425 Jülich,Germany.Corrected:Institute of Energy and Climate Research:Materials Synthesis and Processing(IEK-1),Forschungszentrum Jülich GmbH,52425 Jülich,Germany. 展开更多
关键词 correction ZINC ELECTRODE
在线阅读 下载PDF
Correction to:Feasibility study of the photonuclear reaction cross section of medical radioisotopes using a laser Compton scattering gamma source
20
作者 Yu-Ning Gu Wei-Juan Zhao +5 位作者 Xi-Guang Cao Yu-Xuan Yang Ting-Kai Ma Zheng-Li Liao Fei-Long Xu Yu-Gang Ma 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第11期244-244,共1页
Correction to:Nuclear Science and Techniques(2024)35:155 https://doi.org/10.1007/s41365-024-01481-7 In Eq.(2)of this article,the term'i'should be denoted as a subscript,the corrected equation should read N_(0)... Correction to:Nuclear Science and Techniques(2024)35:155 https://doi.org/10.1007/s41365-024-01481-7 In Eq.(2)of this article,the term'i'should be denoted as a subscript,the corrected equation should read N_(0)=σ(E)N_(t)QC_(kbeam)^(e^(-λt_(i)))∫_(0)^(t_(i))e^(λt)dt,(2)The original article has been corrected. 展开更多
关键词 corrected EQUATION CROSS
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部