Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of...Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of PMSM. Thus, an inter-turn short-circuit fault(ITSCF) diagnosis method based on high frequency(HF) voltage residual is proposed in this paper with proper HF signal injection. First, the analytical models of PMSM after the ITSCF are deduced. Based on the model, the voltage residual at low frequency(LF) and HF can be obtained. It is revealed that the HF voltage residual has a stronger ITSCF detection capability compared to the LF voltage residual. To obtain optimal fault signature, a 3-phase symmetrical HF voltage is injected into the machine drive system, and the HF voltage residuals are extracted. The fault indicator is defined as the standard deviation of the 3-phase HF voltage residuals. The effectiveness of the proposed ITSCF diagnosis method is verified by experiments on a triple 3-phase PMSM. It is worth noting that no extra hardware equipment is required to implement the proposed method.展开更多
This paper presents a new approach to alleviate the harmonics and to enhance the power factor of the ASD (adjustable speed drive). A conventional ASD with 2-level PWM (pulse width modulation) inverters generate hi...This paper presents a new approach to alleviate the harmonics and to enhance the power factor of the ASD (adjustable speed drive). A conventional ASD with 2-level PWM (pulse width modulation) inverters generate high dv/dt and high frequency common mode voltages which are harmful for the drive applications. It reduces the motor bearings life and conducted EMI (electro magnetic interference) deteriorates the insulation. In this paper, a diode clamped multilevel (3-level) inverter is used to perform dual task. It generates HF (high frequency) current to be injected at the input of the three-phase front-end rectifier thereby improving the harmonic spectra and the power factor. It also drives the induction motor. The salient feature of this paper is that it does not require separate converters for improving power factor and to drive induction motor. Furthermore, inverter switches operate with ZVS (zero voltage switching), thus reducing the switching losses substantially, The voltage stress of the switches also has been reduced to half of the conventional 2-level converter. The inverter is operated with SPWM (sinusoidal pulse width modulation) technique. The simulation results for a prototype of 2.2 kW are presented.展开更多
For permanent magnet synchronous machines(PMSMs),accurate inductance is critical for control design and condition monitoring.Owing to magnetic saturation,existing methods require nonlinear saturation model and measure...For permanent magnet synchronous machines(PMSMs),accurate inductance is critical for control design and condition monitoring.Owing to magnetic saturation,existing methods require nonlinear saturation model and measurements from multiple load/current conditions,and the estimation is relying on the accuracy of saturation model and other machine parameters in the model.Speed harmonic produced by harmonic currents is inductance-dependent,and thus this paper explores the use of magnitude and phase angle of the speed harmonic for accurate inductance estimation.Two estimation models are built based on either the magnitude or phase angle,and the inductances can be from d-axis voltage and the magnitude or phase angle,in which the filter influence in harmonic extraction is considered to ensure the estimation performance.The inductances can be estimated from the measurements under one load condition,which is free of saturation model.Moreover,the inductance estimation is robust to the change of other machine parameters.The proposed approach can effectively improve estimation accuracy especially under the condition with low current magnitude.Experiments and comparisons are conducted on a test PMSM to validate the proposed approach.展开更多
基金supported in part by the Jiangsu Carbon Peak Carbon Neutralization Science and Technology Innovation Special Fund under Grant BE2022032-1National Natural Science Foundation of China under Grant 52277035, Grant 51937006 and Grant 51907028the “SEU Zhishan Young Scholars” Program of Southeast University。
文摘Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of PMSM. Thus, an inter-turn short-circuit fault(ITSCF) diagnosis method based on high frequency(HF) voltage residual is proposed in this paper with proper HF signal injection. First, the analytical models of PMSM after the ITSCF are deduced. Based on the model, the voltage residual at low frequency(LF) and HF can be obtained. It is revealed that the HF voltage residual has a stronger ITSCF detection capability compared to the LF voltage residual. To obtain optimal fault signature, a 3-phase symmetrical HF voltage is injected into the machine drive system, and the HF voltage residuals are extracted. The fault indicator is defined as the standard deviation of the 3-phase HF voltage residuals. The effectiveness of the proposed ITSCF diagnosis method is verified by experiments on a triple 3-phase PMSM. It is worth noting that no extra hardware equipment is required to implement the proposed method.
文摘This paper presents a new approach to alleviate the harmonics and to enhance the power factor of the ASD (adjustable speed drive). A conventional ASD with 2-level PWM (pulse width modulation) inverters generate high dv/dt and high frequency common mode voltages which are harmful for the drive applications. It reduces the motor bearings life and conducted EMI (electro magnetic interference) deteriorates the insulation. In this paper, a diode clamped multilevel (3-level) inverter is used to perform dual task. It generates HF (high frequency) current to be injected at the input of the three-phase front-end rectifier thereby improving the harmonic spectra and the power factor. It also drives the induction motor. The salient feature of this paper is that it does not require separate converters for improving power factor and to drive induction motor. Furthermore, inverter switches operate with ZVS (zero voltage switching), thus reducing the switching losses substantially, The voltage stress of the switches also has been reduced to half of the conventional 2-level converter. The inverter is operated with SPWM (sinusoidal pulse width modulation) technique. The simulation results for a prototype of 2.2 kW are presented.
基金supported in part by the National Natural Science Foundation of China(62473387)the Southern Marine Science and Engineering Guangdong Laboratory(Zhuhai)(SML2023SP241)the Department of Science and Technology of Guangdong Province(2021QN020085)。
文摘For permanent magnet synchronous machines(PMSMs),accurate inductance is critical for control design and condition monitoring.Owing to magnetic saturation,existing methods require nonlinear saturation model and measurements from multiple load/current conditions,and the estimation is relying on the accuracy of saturation model and other machine parameters in the model.Speed harmonic produced by harmonic currents is inductance-dependent,and thus this paper explores the use of magnitude and phase angle of the speed harmonic for accurate inductance estimation.Two estimation models are built based on either the magnitude or phase angle,and the inductances can be from d-axis voltage and the magnitude or phase angle,in which the filter influence in harmonic extraction is considered to ensure the estimation performance.The inductances can be estimated from the measurements under one load condition,which is free of saturation model.Moreover,the inductance estimation is robust to the change of other machine parameters.The proposed approach can effectively improve estimation accuracy especially under the condition with low current magnitude.Experiments and comparisons are conducted on a test PMSM to validate the proposed approach.