The systematical study on the model of diatone in Putonghua on the basis of real materials through the techniques of polynomial curve fitting and VQ (vector quantization) are presented. The results show: 1. Most of th...The systematical study on the model of diatone in Putonghua on the basis of real materials through the techniques of polynomial curve fitting and VQ (vector quantization) are presented. The results show: 1. Most of the diatones have several sub-classes, though the scatter of some diatone samples is small. It means that an average model is not sufficient enough to represent all samples in a sub-class. 2. The differences between the diatone model are incarnated on the differences of the highest values of Fo contours, which are correlated with the stress of the first or second syllable. 3. It is a practical and effective method in modeling the diatones in Putonghua through the techniques of polynomial curve fitting and VQ.展开更多
目的:通过与非接触式眼压计(non-contact tonometer,NCT)的比较,评价Diaton眼压计(DT)在准分子激光原位角膜磨镶术(laser in situkeratomileusis,LASIK)前后眼压测量中的应用价值。方法:在LASIK术前及术后1mo,分别使用NCT和DT测量患者眼...目的:通过与非接触式眼压计(non-contact tonometer,NCT)的比较,评价Diaton眼压计(DT)在准分子激光原位角膜磨镶术(laser in situkeratomileusis,LASIK)前后眼压测量中的应用价值。方法:在LASIK术前及术后1mo,分别使用NCT和DT测量患者眼压,使用SPSS13.0统计软件对所得结果进行统计学分析。结果:术后1mo时,NCT眼压测量值较术前下降(5.76±2.31)mmHg,DT眼压测量值则无显著差异(t=0.70,P=0.487);NCT与DT读数测量值差值与术中切削量呈正相关,与术后中央角膜厚度呈负相关。结论:Diaton测量眼压不受角膜厚度的影响,因此更适用于LASIK术后患者的眼压测量。展开更多
AIM: To Investigate the added value of using a Diaton transpalpebral tonometer (DT) to measure lOP in keretoconus. Most type of tonometers use corneal applanation or biomechanical resistance to measure intraocular ...AIM: To Investigate the added value of using a Diaton transpalpebral tonometer (DT) to measure lOP in keretoconus. Most type of tonometers use corneal applanation or biomechanical resistance to measure intraocular pressure (lOP); however, these factors can be altered by keratoconus. Specifically, we examined whether DT can detect false-negative low Goldmann applanation tonometry (AT) measurements. METHODS: Patients with keratoconus were recruited from our tertiary academic treatment center. Measurements included AT and DT (in random order) and Scheimpflug imaging. An age- and gender-matched group of control subjects with no history of corneal disease or glaucoma was also recruited. RESULTS: In total, 130 eyes from 66 participants were assessed. In the keratoconus group, mean AT was 11.0± 2.6, mean DT 11±5.5 (P =0.729)and the two measures were correlated significantly(P=0.006, R=0.323). However, a Bland-Altman plot revealed a wide distribution and poor agreement between both measurements. Previous corneal crosslinking, corneal pachymetry, and Krumeich classification had no effect on measured IOP. CONCLUSION: Measurements obtained using a Diaton tonometer are not affected by corneal biomechanics; however, its poor agreement with Goldmann AT values calls into question the added value of using a Diaton tonometer to measure lOP in keratoconus.展开更多
Basing upon the tonality analytic method, the present paper aims at: (1) Drawing attention to the subordination of the minor key vs. the major key in the chord classification, using the same methodology; and (2) ...Basing upon the tonality analytic method, the present paper aims at: (1) Drawing attention to the subordination of the minor key vs. the major key in the chord classification, using the same methodology; and (2) Showing the differences for the major key and the minor (harmonic) key in the classification of chords, as an aspect of importance for interpreting a piece's tonal structure diagram. The relations between chords appearing in the major and minor (harmonic) key will be shown by applying the comparisons of: (1) third-based chords; and (2) degrees in the C major and A minor keys, on which the same diatonic chords appear.展开更多
基金Department of Computer Sciences, the University of Hong Kong Department of Electronic Engineering, the City University of Ho
文摘The systematical study on the model of diatone in Putonghua on the basis of real materials through the techniques of polynomial curve fitting and VQ (vector quantization) are presented. The results show: 1. Most of the diatones have several sub-classes, though the scatter of some diatone samples is small. It means that an average model is not sufficient enough to represent all samples in a sub-class. 2. The differences between the diatone model are incarnated on the differences of the highest values of Fo contours, which are correlated with the stress of the first or second syllable. 3. It is a practical and effective method in modeling the diatones in Putonghua through the techniques of polynomial curve fitting and VQ.
文摘目的:通过与非接触式眼压计(non-contact tonometer,NCT)的比较,评价Diaton眼压计(DT)在准分子激光原位角膜磨镶术(laser in situkeratomileusis,LASIK)前后眼压测量中的应用价值。方法:在LASIK术前及术后1mo,分别使用NCT和DT测量患者眼压,使用SPSS13.0统计软件对所得结果进行统计学分析。结果:术后1mo时,NCT眼压测量值较术前下降(5.76±2.31)mmHg,DT眼压测量值则无显著差异(t=0.70,P=0.487);NCT与DT读数测量值差值与术中切削量呈正相关,与术后中央角膜厚度呈负相关。结论:Diaton测量眼压不受角膜厚度的影响,因此更适用于LASIK术后患者的眼压测量。
文摘AIM: To Investigate the added value of using a Diaton transpalpebral tonometer (DT) to measure lOP in keretoconus. Most type of tonometers use corneal applanation or biomechanical resistance to measure intraocular pressure (lOP); however, these factors can be altered by keratoconus. Specifically, we examined whether DT can detect false-negative low Goldmann applanation tonometry (AT) measurements. METHODS: Patients with keratoconus were recruited from our tertiary academic treatment center. Measurements included AT and DT (in random order) and Scheimpflug imaging. An age- and gender-matched group of control subjects with no history of corneal disease or glaucoma was also recruited. RESULTS: In total, 130 eyes from 66 participants were assessed. In the keratoconus group, mean AT was 11.0± 2.6, mean DT 11±5.5 (P =0.729)and the two measures were correlated significantly(P=0.006, R=0.323). However, a Bland-Altman plot revealed a wide distribution and poor agreement between both measurements. Previous corneal crosslinking, corneal pachymetry, and Krumeich classification had no effect on measured IOP. CONCLUSION: Measurements obtained using a Diaton tonometer are not affected by corneal biomechanics; however, its poor agreement with Goldmann AT values calls into question the added value of using a Diaton tonometer to measure lOP in keratoconus.
文摘Basing upon the tonality analytic method, the present paper aims at: (1) Drawing attention to the subordination of the minor key vs. the major key in the chord classification, using the same methodology; and (2) Showing the differences for the major key and the minor (harmonic) key in the classification of chords, as an aspect of importance for interpreting a piece's tonal structure diagram. The relations between chords appearing in the major and minor (harmonic) key will be shown by applying the comparisons of: (1) third-based chords; and (2) degrees in the C major and A minor keys, on which the same diatonic chords appear.