The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw...The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.展开更多
The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational pri...The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.展开更多
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi...A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.展开更多
In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection sho...In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.展开更多
基金Project (No. 50477033) supported by the National Natural Science Foundation of China
文摘The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.
基金Project (No. 50477033) supported by the National Natural ScienceFoundation of China
文摘The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.
基金supported by the Shanghai Leading Academic Discipline Project (Grant No.T0103)
文摘A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.
文摘In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.