期刊文献+
共找到1,093篇文章
< 1 2 55 >
每页显示 20 50 100
Lung ultrasound score evaluation of the effect of pressure-controlled ventilation volume-guaranteed on patients undergoing laparoscopicassisted radical gastrectomy
1
作者 Jian Tan Cheng-Ming Bao Xiao-Yuan Chen 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1717-1725,共9页
BACKGROUND Laparoscopic-assisted radical gastrectomy(LARG)is the standard treatment for early-stage gastric carcinoma(GC).However,the negative impact of this proce-dure on respiratory function requires the optimized i... BACKGROUND Laparoscopic-assisted radical gastrectomy(LARG)is the standard treatment for early-stage gastric carcinoma(GC).However,the negative impact of this proce-dure on respiratory function requires the optimized intraoperative management of patients in terms of ventilation.AIM To investigate the influence of pressure-controlled ventilation volume-guaranteed(PCV-VG)and volume-controlled ventilation(VCV)on blood gas analysis and pulmonary ventilation in patients undergoing LARG for GC based on the lung ultrasound score(LUS).METHODS The study included 103 patients with GC undergoing LARG from May 2020 to May 2023,with 52 cases undergoing PCV-VG(research group)and 51 cases undergoing VCV(control group).LUS were recorded at the time of entering the operating room(T0),20 minutes after anesthesia with endotracheal intubation(T1),30 minutes after artificial pneumoperitoneum(PP)establishment(T2),and 15 minutes after endotracheal tube removal(T5).For blood gas analysis,arterial partial pressure of oxygen(PaO_(2))and partial pressure of carbon dioxide(PaCO_(2))were observed.Peak airway pressure(P_(peak)),plateau pressure(Pplat),mean airway pressure(P_(mean)),and dynamic pulmonary compliance(C_(dyn))were recorded at T1 and T2,1 hour after PP establishment(T3),and at the end of the operation(T4).Postoperative pulmonary complications(PPCs)were recorded.Pre-and postoperative serum interleukin(IL)-1β,IL-6,and tumor necrosis factor-α(TNF-α)were measured by enzyme-linked immunosorbent assay.RESULTS Compared with those at T0,the whole,anterior,lateral,posterior,upper,lower,left,and right lung LUS of the research group were significantly reduced at T1,T2,and T5;in the control group,the LUS of the whole and partial lung regions(posterior,lower,and right lung)decreased significantly at T2,while at T5,the LUS of the whole and some regions(lateral,lower,and left lung)increased significantly.In comparison with the control group,the whole and regional LUS of the research group were reduced at T1,T2,and T5,with an increase in PaO_(2),decrease in PaCO_(2),reduction in P_(peak) at T1 to T4,increase in P_(mean) and C_(dyn),and decrease in Pplat at T4,all significant.The research group showed a significantly lower incidence of PPCs than the control group within 3 days postoperatively.Postoperative IL-1β,IL-6,and TNF-αsignificantly increased in both groups,with even higher levels in the control group.CONCLUSION LUS can indicate intraoperative non-uniformity and postural changes in pulmonary ventilation under PCV-VG and VCV.Under the lung protective ventilation strategy,the PCV-VG mode more significantly improved intraop-erative lung ventilation in patients undergoing LARG for GC and reduced lung injury-related cytokine production,thereby alleviating lung injury. 展开更多
关键词 Lung ultrasound score Pressure-controlled ventilation volume-guaranteed Laparoscopic-assisted radical gastrectomy Blood gas analysis indexes Pulmonary ventilation
在线阅读 下载PDF
Innovative Mechanical Ventilation Control for Enhanced Indoor Air Quality and Energy Efficiency
2
作者 Giovanni Miracco Francesco Nicoletti +1 位作者 Vittorio Ferraro Dimitrios Kaliakatsos 《Energy Engineering》 2025年第3期861-883,共23页
Indoor air quality(IAQ)is often overlooked,yet a poorly maintained environment can lead to significant health issues and reduced concentration and productivity in work or educational settings.This study presents an in... Indoor air quality(IAQ)is often overlooked,yet a poorly maintained environment can lead to significant health issues and reduced concentration and productivity in work or educational settings.This study presents an innovative control system for mechanical ventilation specifically designed for university classrooms,with the dual goal of enhancing IAQ and increasing energy efficiency.Two classrooms with distinct construction characteristics were analyzed:one with exterior walls and windows,and the other completely underground.For each classroom,a model was developed using DesignBuilder software,which was calibrated with experimental data regarding CO_(2) concentration,temperature,and relative humidity levels.The proposed ventilation system operates based on CO_(2) concentration,relative humidity,and potential for free heating and cooling.In addition,the analysis was conducted for other locations,demonstrating consistent energy savings across different climates and environments,always showing an annual reduction in energy consumption.Results demonstrate that mechanical ventilation,when integrated with heat recovery and free cooling strategies,significantly reduces energy consumption by up to 25%,while also maintaining optimal CO_(2) levels to enhance comfort and air quality.These findings emphasize the essential need for well-designed mechanical ventilation systems to ensure both psychophysical well-being and IAQ in enclosed spaces,particularly in environments intended for extended occupancy,such as classrooms.Furthermore,this approach has broad applicability,as it could be adapted to various building types,thereby contributing to sustainable energy management practices and promoting healthier indoor spaces.This study serves as a model for future designs aiming to balance energy efficiency with indoor air quality,especially relevant in the post-COVID era,where the importance of indoor air quality has become more widely recognized. 展开更多
关键词 Indoor air quality mechanical ventilation system innovative control system energy efficiency Energy-Plus simulation
在线阅读 下载PDF
Critical factors to formatting and stabilizing the vortex flow in the vortex ventilation system
3
作者 Chen Zhang Yuqing Bai +5 位作者 Zhixiang Cao Zefang Yang Tongtong Zhao Chao Zhai Wenchao Lv Yi Wang 《Building Simulation》 2025年第2期403-421,共19页
Vortex ventilation,which utilizes vortex airflow to effectively transport pollutants over long distances,is a promising method for pollution control in large spatial structures.The performance of vortex ventilation he... Vortex ventilation,which utilizes vortex airflow to effectively transport pollutants over long distances,is a promising method for pollution control in large spatial structures.The performance of vortex ventilation heavily depends on the stable generation and maintenance of column vortex airflow,necessitating a comprehensive understanding of the interactions among supply airflow,exhaust airflow,and pollutant airflow.In this study,experimental method and transient computational fluid dynamics(CFD)method were employed to quantitatively analyze the influence of supply airflow characteristics and parameters on the formation of vortex airflow.It was found that impingements between supply jet streams significantly affect the generation of vortex ventilation.Based on variations in the flow shape of supply jet streams,the process of vortex airflow formation can be divided into three stages:initiation,oscillation,and stabilization.As the airflow rate increases,the impingement effect between the air jet streams makes the vortex unstable and the vortex intensity decreases.Optimization strategies were proposed to modify system geometry,including increasing the number of supply air inlets,adjusting the horizontal deflection angle of supply air,and enlarging the size of supply air inlets.Increasing the horizontal deflection angle of supply air was shown to minimize the negative pressure within the flow field to a minimum of−12 Pa and reduce the coefficient of variation to a minimum of 0.01,which proved most effective in enhancing vortex stability. 展开更多
关键词 vortex ventilation system column air vortex transient CFD swirl ratio angular momentum
原文传递
Experimental and numerical study on attenuation of shock waves in ventilation pipes
4
作者 Wenjun Yu Shuxin Deng +5 位作者 Shengyun Chen Bingbing Yu Dongyan Jin Zhangjun Wu Yaguang Sui Huajie Wu 《Defence Technology(防务技术)》 2025年第4期156-168,共13页
With different structural forms of ventilation pipes have various attenuation effects on incident shock waves while meeting ventilation requirements.The attenuation mechanism and the propagation law of shock waves in ... With different structural forms of ventilation pipes have various attenuation effects on incident shock waves while meeting ventilation requirements.The attenuation mechanism and the propagation law of shock waves in ventilation pipes of different structures are investigated by experiments and numerical simulations.Furthermore,for the same structure,the effects of peak pressure and positive pressure time on the attenuation rate are discussed.It is found that the attenuation rate increases with the incident shock wave pressure,and the shock wave attenuation rate tends to reach its limiting value k for the same structure and reasonably short positive pressure time.Under the same conditions,the attenuation rate is calculated using the pressure of the shock wave as follows:diffusion chamber pipe,branch pipe and selfconsumption pipe;the attenuation rate per unit volume is calculated as follows:self-consumption pipe,branch pipe and diffusion chamber pipe.In addition,an easy method is provided to calculate the attenuation rate of the shock wave in single and multi-stage ventilation pipes.Corresponding parameters are provided for various structures,and the margin of error between the formulae and experimental results is within 10%,which is significant for engineering applications. 展开更多
关键词 Hock waves ventilation pipes Numerical modelling Explosion mechanics
在线阅读 下载PDF
Influence of trains meeting on the ventilation performance of equipment compartment with independent air duct in high-speed train:numerical and experimental study
5
作者 Yitong Wu Wei Zhou +5 位作者 Xifeng Liang Xinchao Su Kewei Xu Yutao Xia Zhixin Wang Sinisa Krajnović 《Railway Engineering Science》 2025年第1期127-150,共24页
During the train meeting events,train equipment compartments are exposed to the worst pressure changes,potentially affecting the ventilation performance of equipment,particularly for electrical facilities equipped wit... During the train meeting events,train equipment compartments are exposed to the worst pressure changes,potentially affecting the ventilation performance of equipment,particularly for electrical facilities equipped with independent air ducts.In this paper,a two-step method is used for numerical computation:(1)obtaining the temporal and spatial transient node data of the flow field sections during the train-passing simulation and(2)using the data as the input data for the equipment compartment simulation.In addition,this paper also compares the difference in equipment ventilation between the single-train and trainpassing scenarios in real vehicle tests.The results indicate that the primary factors influencing ventilation effectiveness are the aerodynamic compression and deceleration of airflow induced by the other train's nose,as well as the instability of the external flow field in the wake of the other train.During train crossing,the air is forced into the air duct,with a maximum ratio of the airflow in-duct to the airflow out-duct reaching 3.2.The average mass flow falls below the rated mass flow for the converter.Compared to the rated air volume of converter,the maximum suppression rates obtained from testing and simulation are-24.5%and-16.8%,respectively.Compared to the single-train operation,the maximum suppression rates obtained from testing and simulation are-15%and-18%,respectively.These findings provide valuable insights into the design and operation of high-speed trains. 展开更多
关键词 Train-passing event Electrical facilities Independent air duct ventilation performance
在线阅读 下载PDF
Rapid imaging of pulmonary ventilation function evaluation with ^(129)Xe MRI
6
作者 Li Fan Shiyuan Liu 《Magnetic Resonance Letters》 2025年第1期77-78,共2页
A recent study on the rapid imaging of pulmonary ventilation using hyperpolarized ^(129)Xe MRI has demonstrated the ability to achieve isotropic 3D ventilation imaging with a spatial resolution of 3×3×3mm^(3... A recent study on the rapid imaging of pulmonary ventilation using hyperpolarized ^(129)Xe MRI has demonstrated the ability to achieve isotropic 3D ventilation imaging with a spatial resolution of 3×3×3mm^(3) in humans,within an acquisition time of just 3.5 seconds(https://doi.org/10.1002/mrm.30120). 展开更多
关键词 ventilation PULMONARY (1
在线阅读 下载PDF
Predictive Value of Diaphragmatic Thickening Fraction Combined with Cough Peak Flow Rate for Weaning from Mechanical Ventilation
7
作者 Yaqiang Wei 《Journal of Clinical and Nursing Research》 2025年第3期241-247,共7页
Objective:To investigate the predictive value of diaphragm thickening fraction(DTF)combined with cough peak expiratory flow(CPEF)on the success rate of weaning from mechanical ventilation.Methods:The clinical data of ... Objective:To investigate the predictive value of diaphragm thickening fraction(DTF)combined with cough peak expiratory flow(CPEF)on the success rate of weaning from mechanical ventilation.Methods:The clinical data of patients undergoing invasive mechanical ventilation via oral endotracheal intubation in the ICU of our hospital from January 2022 to December 2023 were studied.All patients underwent a 30-minute spontaneous breathing trial(SBT)using low-level pressure support ventilation(PSV)after meeting the clinical weaning screening criteria.Among them,150 patients who met the clinical weaning criteria were weaned from the ventilator.They were divided into a successful weaning group(n=100)and a failed weaning group(n=50)based on the weaning outcome.Clinical data,including age,gender,APACHE II score,duration of mechanical ventilation,DTF,and CPEF,were collected from 150 patients.The differences in clinical data between the two groups were compared,and the correlation between DTF,CPEF,and the success rate of weaning was analyzed.Results:There were no significant differences between the two groups in gender ratio(χ^(2)=0.884,P=0.347>0.05),age(t=0.350,P=0.727>0.05),and APACHE II score(t=1.295,P=0.197>0.05),but there was a significant difference in the duration of mechanical ventilation(t=3.766,P<0.001).The DTF and CPEF values in the successful weaning group were significantly higher than those in the failed weaning group(P<0.05).ROC curves were drawn to predict the weaning results using DTF,CPEF,and the combination of DTF and CPEF.The results showed that the specificity of the combination of DTF and CPEF was comparable to that of either metric alone,but the sensitivity and AUC were significantly higher than those of either metric alone.Conclusion:The combination of DTF and CPEF can be used as an effective indicator to evaluate the weaning efficacy of mechanically ventilated patients,which has important clinical significance for guiding clinical weaning treatment,improving the success rate of weaning,reducing the incidence of ventilator-associated pneumonia,and shortening the length of hospital stay. 展开更多
关键词 diaphragm thickening fraction cough peak expiratory flow mechanically ventilated patients WEANING
在线阅读 下载PDF
Expression Changes of Early Response Genes in Lung Due to High Volume Ventilation 被引量:2
8
作者 王月兰 姚尚龙 熊平 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第3期339-342,共4页
The expression changes of early response genes due to ventilation with high volume in adult rats in vivo were observed. Forty SD male rats were randomly divided into control and 30, 60, 90 and 120 min ventilation grou... The expression changes of early response genes due to ventilation with high volume in adult rats in vivo were observed. Forty SD male rats were randomly divided into control and 30, 60, 90 and 120 min ventilation groups, respectively (n=8 in each group). The animals were ventilated with tidal volume of 42 ml/kg and a PEEP level of 0 cmH_2O at a rate of 40 breaths per minute in room air with a ventilator was given to the small animals. The expression of Egr-1, C-jun and IL-1β mRNA and proteins was detected by RT-PCR and immunohistochemical technique, respectively. The pathological changes in lung tissues were examined by HE staining. The results indicated that the expression of Egr-1, C-jun and IL-1β mRNA was detectable at 30th min after overventilation, but there was no significant difference in comparison with that in control group until overventilation for 60 min. However, at 90 and 120 min there was a significent increase as compared with 30 min or control group (P<0.05). The expression of Egr-1, C-jun and IL-1β deteced by immunohistochemical assay also showed a similar tendency of the gradual increase. In the 120 min ventilation group, the expression intensity of Egr-1, C-jun and IL-1β proteins in lung cells was the strongest and the nuclear translocation was increased markedly in comparison with any other groups (P<0.05). HE staining suggested that the degree of lung injury was aggravated gradually with the ventialtion going on and had a similar tendency to the expression of these early response genes and proteins. The current data suggested that overventilation activated and upregulated the expression of early response genes and the expression of these genes may be taken as the early signal to predict the onset and degree of lung injury. These results may demonstrated partially that the expression of early response genes induced by the mechanical stretch is associated with biochamic lung injury. 展开更多
关键词 mechanical ventilation lung injury early response gene transcription factor
在线阅读 下载PDF
Effect of glucocorticoid on MIP-1α and NF-кb expressing in the lung of rats undergoing mechanical ventilation with a high tidal volume 被引量:4
9
作者 Zhi-hong Liu Xin-ri Zhang +3 位作者 Xiao-yun Hu Meng-yu Cheng Jian-ying Xu Yong-cheng Du 《World Journal of Emergency Medicine》 CAS 2011年第1期66-69,共4页
BACKGROUND: Ventilator induced lung injury (VILI) is a serious complication in the treatment of mechanical ventilating patients, and it is also the main cause that results in exacerbation or death of patients. In t... BACKGROUND: Ventilator induced lung injury (VILI) is a serious complication in the treatment of mechanical ventilating patients, and it is also the main cause that results in exacerbation or death of patients. In this study, we produced VILI models by using glucocorticoid in rats with high tidal volume mechanical ventilation, and observed the content of macrophage inflammatory protein-1α (MIP-1α) in plasma and bronchoalveolar lavage fluid (BALF) and the expression of MIP-1α mRNA and nuclear factor-kappa B (NF-кB) p65 mRNA in the lung so as to explore the role of glucocorticoid in mechanical ventilation.METHODS: Thirty-two healthy Wistar rats were randomly divided into a control group, a ventilator induced lung injury (VILI) group, a dexamethasone (DEX) group and a budesonide (BUD) group. The content of MIP-1a in plasma and BALF was measured with ELISA and the level of MIP-1α mRNA and NF-кBp65 mRNA expressing in the lung of rats were detected by RT-PCR. The data were expressed as mean±SD and were compared between the groups.RESULTS: The content of MIP-1α in plasma and BALF and the level of MIP-1α mRNA and NF-кBp65 mRNA in the lung in the DEX and BUD groups were signifi cantly lower than those in the VILI group (P〈0.001). Although the content of MIP-1α in plasma and BALF and the level of MIP-1α mRNA and NF-кBp65 mRNA in the lung in the BUD group were higher than those in the DEX group, there were no signifi cant differences between them (P〉0.05).CONCLUSIONS: Glucocorticoid could down-regulate the expression of MIP-1α by inhibiting the activity of NF-кB in the lung and may exert preventive and therapeutic effects on VILI to some extent. The effect of local use of glucocorticoid against VILI is similar to that of systemic use, but there is lesser adverse reaction. 展开更多
关键词 Mechanical ventilation Lung injury Macrophage inflammatory protein-1α Nuclear factor-kappa B GLUCOCORTICOID Infiammation
在线阅读 下载PDF
Respiratory Volume Monitoring to Assess the Effect of Airway Maneuvers on Ventilation during Upper Endoscopy 被引量:1
10
作者 Katherine Holley Donald Mathews +2 位作者 Diane Ladd Lisa Campana Howard Schapiro 《Open Journal of Anesthesiology》 2014年第11期281-290,共10页
Introduction: Propofol use during endoscopic procedures has become increasingly popular and assessing and maintaining airway patency is a significant challenge. Anesthesiologists often use airway maneuvers to maintain... Introduction: Propofol use during endoscopic procedures has become increasingly popular and assessing and maintaining airway patency is a significant challenge. Anesthesiologists often use airway maneuvers to maintain airway patency and ventilation during procedural sedation. A novel, non-invasive, Respiratory Volume Monitor (RVM) that provided continuous, real-time measurements of minute ventilation (MV), tidal volume (TV) and respiratory rate (RR) was used to monitor respiratory performance before, during, and after endoscopic procedures, quantify MV changes before and after airway maneuvers, and to quantify propofol-induced respiratory depression. Methods: RVM traces were obtained from 25 patients undergoing sedation for endoscopic procedures. Airway maneuvers were performed in 19/25 patients. All 25 patients received propofol as the primary sedative. Results: Forty-five airway maneuvers were performed. During these maneuvers, all respiratory parameters increased relative to pre-maneuver levels. On average, MV increased by 24% ± 5% (mean ± SEM), TV 14% ± 5% and RR: 17% ± 6%. The cohort average MVBASELINE was 9.5 ± 0.7 L/min (TV = 670 ± 60 ml, RR = 15 ± 0.7). Following propofol MV decreased transiently, reaching nadir five minutes after the last dose of propofol at 82% ± 10% of baseline (MV = 7.5 ± 1.0 L/min). The reduction in MV was driven by reduction in TV, not RR. Conclusions: Data demonstrated that RVM was able to track changes in ventilation and was able to quantify respiratory changes following airway maneuvers. All patients had a significant reduction in ventilatory volumes after propofol. Five minutes after the last dose of propofol, MV and TV were significantly reduced while RR was not, suggesting that monitoring respiratory rate alone was not a sufficient indicator of respiratory status. 展开更多
关键词 Non-Invasive RESPIRATORY volume MONITORING Minute ventilation Airway MANEUVERS PROCEDURAL SEDATION Endoscopy
在线阅读 下载PDF
Influences of the Fresh Air Volume on the Removal of Cough-Released Droplets in a Passenger Car of a High-Speed Train Using CFD 被引量:1
11
作者 Jun Xu Kai Bi +7 位作者 Yibin Lu TiantianWang Hang Zhang Zeyuan Zheng Fushan Shi Yaxin Zheng Xiaoying Li Jingping Yang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2727-2748,共22页
The spread and removal of pollution sources,namely,cough-released droplets in three different areas(front,middle,and rear areas)of a fully-loaded passenger car in a high-speed train under different fresh air flow volu... The spread and removal of pollution sources,namely,cough-released droplets in three different areas(front,middle,and rear areas)of a fully-loaded passenger car in a high-speed train under different fresh air flow volume were studied using computational fluid dynamics(CFD)method.In addition,the structure of indoor flow fields was also analysed.The results show that the large eddies are more stable and flow faster in the air supply under Mode 2(fresh air volume:2200m3/h)compared to Mode 1(fresh air volume:1100m3/h).By analysing the spreading process of droplets sprayed at different locations in the passenger car and with different particle sizes,the removal trends for droplets are found to be similar under the two air supply modes.However,when increasing the fresh air flow volume,the droplets in the middle and front areas of the passenger car are removed faster.When the droplets had dispersed for 60s,Mode 2 exhibited a removal rate approximately 1%–3%higher than Mode 1 for small and medium-sized droplets with diameters of 10 and 50μm.While those in the rear area,the situation is reversed,with Mode 1 slightly surpassing Mode 2 by 1%–3%.For large droplets with a diameter of 100μm,both modes achieved a removal rate of over 96%in all three regions at the 60 s.The results can provide guidance for air supply modes of passenger cars of high-speed trains,thus suppressing the spread of virus-carrying droplets and reducing the risk of viral infection among passengers. 展开更多
关键词 Cough-released pollutants CFD ventilation inside trains supply air volume
在线阅读 下载PDF
Driving pressure in mechanical ventilation:A review 被引量:3
12
作者 Syeda Farheen Zaidi Asim Shaikh +2 位作者 Daniyal Aziz Khan Salim Surani Iqbal Ratnani 《World Journal of Critical Care Medicine》 2024年第1期15-27,共13页
Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP lev... Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP levels have also been shown to closely impact hard endpoints such as mortality.Considering this,conducting an in-depth review ofΔP as a unique,outcome-impacting therapeutic modality is extremely important.There is a need to understand the subtleties involved in making sureΔP levels are optimized to enhance outcomes and minimize harm.We performed this narrative review to further explore the various uses ofΔP,the different parameters that can affect its use,and how outcomes vary in different patient populations at different pressure levels.To better utilizeΔP in MV-requiring patients,additional large-scale clinical studies are needed. 展开更多
关键词 Driving pressure Acute respiratory distress syndrome MORTALITY Positive end-expiratory pressure Ventilator induced lung injury Mechanical ventilation
在线阅读 下载PDF
Effects of acetylcysteine on micro-inflammation and pulmonary ventilation in chronic obstructive pulmonary disease exacerbation 被引量:1
13
作者 Li-Yuan Huang Bin Huang +1 位作者 Zheng Lv Xiao-Dan Lu 《World Journal of Clinical Cases》 SCIE 2024年第18期3482-3490,共9页
BACKGROUND Acute exacerbation of chronic obstructive pulmonary disease(AECOPD)is a serious complication of chronic obstructive pulmonary disease,often characterized by increased morbidity and mortality.In traditional ... BACKGROUND Acute exacerbation of chronic obstructive pulmonary disease(AECOPD)is a serious complication of chronic obstructive pulmonary disease,often characterized by increased morbidity and mortality.In traditional Chinese medicine,AECOPD is linked to phlegm-heat and blood-stasis,presenting symptoms like thick sputum,fever,and chest pain.It has been shown that acetylcysteine inhalation in conjunction with conventional therapy significantly reduced inflammatory markers and improved lung function parameters in patients with AECOPD,suggesting that acetylcysteine may be an important adjunctive therapy for patients with phlegm-heat-blood stasis type AECOPD.AIM To investigate the effect of acetylcysteine on microinflammation and lung ventilation in patients with phlegm-heat and blood-stasis-type AECOPD.METHODS One hundred patients with phlegm-heat and blood-stasis-type AECOPD were randomly assigned to two groups.The treatment group received acetylcysteine inhalation(10%solution,5 mL,twice daily)along with conventional therapy,whereas the control group received only conventional therapy.The treatment duration was 14 d.Inflammatory markers(C-reactive protein,interleukin-6,and tumor necrosis factor-alpha)in the serum and sputum as well as lung function parameters(forced expiratory volume in one second,forced vital capacity,and peak expiratory flow)were assessed pre-and post-treatment.Acetylcysteine inhalation led to significant reductions in inflammatory markers and improvements in lung function parameters compared to those in the control group(P<0.05).This suggests that acetylcysteine could serve as an effective adjunct therapy for patients with phlegm-heat and blood-stasis-type AECOPD.RESULTS Acetylcysteine inhalation significantly reduced inflammatory markers in the serum and sputum and improved lung ventilation function parameters in patients with phlegm-heat and blood-stasis type AECOPD compared with the control group.These differences were statistically significant(P<0.05).The study concluded that acetylcysteine inhalation had a positive effect on microinflammation and lung ventilation function in patients with this type of AECOPD,suggesting its potential as an adjuvant therapy for such cases.CONCLUSION Acetylcysteine inhalation demonstrated significant improvements in reducing inflammatory markers in the serum and sputum,as well as enhancing lung ventilation function parameters in patients with phlegm-heat and bloodstasis type AECOPD.These findings suggest that acetylcysteine could serve as a valuable adjuvant therapy for individuals with this specific type of AECOPD,offering benefits for managing microinflammation and optimizing lung function. 展开更多
关键词 Acute exacerbation Chronic obstructive pulmonary disease Traditional Chinese medicine ACETYLCYSTEINE Phlegm-heat and blood-stasis Lung ventilation function
在线阅读 下载PDF
Predictive value of diaphragm ultrasound for mechanical ventilation outcome in patients with acute exacerbation of chronic obstructive pulmonary disease 被引量:1
14
作者 Lei-Lei Qu Wen-Ping Zhao +1 位作者 Ji-Ping Li Wei Zhang 《World Journal of Clinical Cases》 SCIE 2024年第26期5893-5900,共8页
BACKGROUND Acute exacerbation of chronic obstructive pulmonary disease(AECOPD)is often combined with respiratory failure,which increases the patient's morbidity and mortality.Diaphragm ultrasound(DUS)has developed... BACKGROUND Acute exacerbation of chronic obstructive pulmonary disease(AECOPD)is often combined with respiratory failure,which increases the patient's morbidity and mortality.Diaphragm ultrasound(DUS)has developed rapidly in the field of critical care in recent years.Studies with DUS monitoring diaphragm-related rapid shallow breathing index have demonstrated important results in guiding intensive care unit patients out of the ventilator.Early prediction of the indications for withdrawal of non-invasive ventilator and early evaluation of patients to avoid or reduce disease progression are very important.AIM To explore the predictive value of DUS indexes for non-invasive ventilation outcome in patients with AECOPD.METHODS Ninety-four patients with AECOPD who received mechanical ventilation in our hospital from January 2022 to December 2023 were retrospectively analyzed,and they were divided into a successful ventilation group(68 cases)and a failed ventilation group(26 cases)according to the outcome of ventilation.The clinical data of patients with successful and failed noninvasive ventilation were compared,and the independent predictors of noninvasive ventilation outcomes in AECOPD patients were identified by multivariate logistic regression analysis.RESULTS There were no significant differences in gender,age,body mass index,complications,systolic pressure,heart rate,mean arterial pressure,respiratory rate,oxygen saturation,partial pressure of oxygen,oxygenation index,or time of inspiration between patients with successful and failed mechanical ventilation(P>0.05).The patients with successful noninvasive ventilation had shorter hospital stays and lower partial pressure of carbon dioxide(PaCO_(2))than those with failed treatment,while potential of hydrogen(pH),diaphragm thickening fraction(DTF),diaphragm activity,and diaphragm movement time were significantly higher than those with failed treatment(P<0.05).pH[odds ratio(OR)=0.005,P<0.05],PaCO_(2)(OR=0.430,P<0.05),and DTF(OR=0.570,P<0.05)were identified to be independent factors influencing the outcome of mechanical ventilation in AECOPD patients.CONCLUSION The DUS index DTF can better predict the outcome of non-invasive ventilation in AECOPD patients. 展开更多
关键词 Diaphragm ultrasound Mechanical ventilation Acute exacerbation of chronic obstructive pulmonary disease Predictive value Diaphragm thickening fraction Diaphragm activity
在线阅读 下载PDF
Correlation analysis of five factors influencing minute volume during high frequency jet ventilation on lung modal: a laboratory study
15
作者 陈敏 曾祥龙 吴兴裕 《Journal of Medical Colleges of PLA(China)》 CAS 1994年第1期47-49,共3页
Five factors influencing minute volume during high frequency jet ventilation were studied on lung modal by stepwise regression analysis. Among these factors, driving pressure is of the greatest dominance. Others are i... Five factors influencing minute volume during high frequency jet ventilation were studied on lung modal by stepwise regression analysis. Among these factors, driving pressure is of the greatest dominance. Others are inspiratory and expiratory time ratio, tube diameter, frequency of ventilation and needle distanee, in the order of their impact. A formula was also developed for predicting the parameters.The result is quite satisfactory. 展开更多
关键词 high frequency JET ventilation MINUTE volume regression analysis
在线阅读 下载PDF
The effect of different inflation volumes of laryngeal mask airway on efficacy of closed circuit controlled ventilation in pediatric cancer patients
16
作者 Magda S.Azer Ayman A.Ghoneim Hossam Z.Ghobrial 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第12期596-601,共6页
Objective: The laryngeal mask airway (LMA) is an established way for airway control during spontaneous ventila- tion. Its ability to deliver positive pressure ventilation without leakage especially in low flow stat... Objective: The laryngeal mask airway (LMA) is an established way for airway control during spontaneous ventila- tion. Its ability to deliver positive pressure ventilation without leakage especially in low flow states is still controversy. The aim of this study is to test the possibility of using LMA in pediatric closed circuit controlled ventilation, and to find out the optimum cuff volume to perform closed system ventilation. Methods: Twenty children scheduled for elective surgeries were enrolled in a crossover study. Laryngeal mask airway was used. In stage I, the cuff was inflated with the maximum volume of air as rec- ommended by the manufacturers. Adjustment of volume of air inflated into the LMA cuff to the minimum volume to obtain the effective seal was done at stage II. The leak pressure, intracuff pressure and the leak volume were measured in both stages. Results: The cuff filling volume was significantly lower compared to the maximum cuff inflation volume in stage I. Leakage values showed significantly less values in stage II of the study with smaller cuff inflation volumes. The airway leakage pressure was significantly lower in stage fl in comparison to stage I. Cuff inflation pressure in stage I showed marked elevation which dropped significantly after adjustment of cuff volume in stage I1. Conclusion: Laryngeal mask airway is an effective tool to provide closed circuit controlled ventilation in pediatrics. Inflation of the cuff by the minimum volume of air needed to reach the just sealing pressure is suggested to minimize the leakage volume. 展开更多
关键词 laryngeal mask airway (LMA) PEDIATRIC controlled ventilation closed circuit intracuff volume leak pressure
在线阅读 下载PDF
Effects of ultrasound monitoring of gastric residual volume on feeding complications,caloric intake and prognosis of patients with severe mechanical ventilation
17
作者 Xiao-Yan Xu Hui-Ping Xue +2 位作者 Ming-Jun Yuan You-Rong Jin Chun-Xia Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第8期1719-1727,共9页
BACKGROUND Monitoring of gastric residual is an important approach for assessing gastric emptying in patients with mechanical ventilation.By monitoring gastric contents,the enteral nutrition scheme can be adjusted in ... BACKGROUND Monitoring of gastric residual is an important approach for assessing gastric emptying in patients with mechanical ventilation.By monitoring gastric contents,the enteral nutrition scheme can be adjusted in time to ensure feeding safety.AIM To investigate the effects of ultrasound monitoring on the incidence of feeding complications,daily caloric intake and prognosis of patients with severe mechanical ventilation.To analyze the clinical significance of ultrasound monitoring of gastric residual volume(GRV)up to 250 mL to provide a theoretical basis for clinical practice.METHODS Patients admitted to the department of emergency medicine of the Affiliated Hospital of Nantong University from January 2018 to June 2022 who received invasive mechanical ventilation and continuous enteral nutrition support within 24-48 h after admission were enrolled in this study.Medical records for patients within 7 d of hospitalization were retrospectively analyzed to compare the incidence of feeding complications,daily caloric intake and clinical prognosis between patients with gastric residual≥250 mL and<250 mL,as monitored by ultrasound on the third day.RESULTS A total of 513 patients were enrolled in this study.Incidences of abdominal distension,diarrhea,and vomiting in the<250 mL and≥250 mL groups were:18.4%vs 21.0%,23.9%vs 32.3%and 4.0%vs 6.5%,respectively;mortality rates were 20.8%vs 22.65%;mechanical ventilation durations were 18.30 d vs 17.56 d while lengths of stay in the intensive care units(ICU)were 19.87 d vs 19.19±5.19 d.Differences in the above factors between groups were not significant.Gastric residual≥250 mL was not an independent risk factor for death and prolonged ICU stay.However,target feeding time of patients in the≥250 mL group was longer than that of patients in the≥250 mL group,and caloric intake(22.0,23.6,24.8,25.3 kcal/kg/d)for patients in the≥250 mL group from the 4^(th) day to the 7^(th) day of hospitalization was lower than that of patients in the≥250 mL group(23.2,24.8,25.7,25.8 kcal/kg/d).On the 4^(th) day(Z=4.324,P=0.013),on the 5^(th) day(Z=3.376,P=0.033),while on the 6^(th) day(Z=3.098,P=0.04),the differences were statistically significant.CONCLUSION The use of ultrasound to monitor GRV and undertaking clinical interventions when the monitoring value is≥250 mL has no significant effects on incidences of feeding complications and clinical prognostic outcomes,however,it significantly prolongs the time to reach target feeding,reduces the daily intake of calories during ICU hospitalization,and increases the risk of insufficient nutrition of patients.The accuracy and necessity of monitoring gastric remnants and monitoring frequencies should be investigated further. 展开更多
关键词 Gastric residual monitoring Mechanical ventilation VOMIT Caloric intake PROGNOSIS
在线阅读 下载PDF
A hybrid ventilation scheme applied to bidirectional excavation tunnel construction with a long inclined shaft
18
作者 YANG Wei-chao WANG Jian +3 位作者 DENG E LIU Yi-kang LUO Lu-sen YANG Jia 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第9期3187-3205,共19页
The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the h... The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the hybrid ventilation system applied in bidirectional excavation tunnels with a long inclined shaft,this study has established a full-scale computational fluid dynamics model based on field tests,the Poly-Hexcore method,and the sliding mesh technique.The distribution of wind speed,temperature field,and CO in the tunnel are taken as indices to compare the ventilation efficiency of three ventilation systems(duct,duct-ventilation shaft,duct–ventilated shaft-axial fan).The results show that the hybrid ventilation scheme based on duct-ventilation shaft–axial fan performs the best among the three ventilation systems.Compared to the duct,the wind speed and cooling rate in the tunnel are enhanced by 7.5%–30.6%and 14.1%–17.7%,respectively,for the duct-vent shaft-axial fan condition,and the volume fractions of CO are reduced by 26.9%–73.9%.This contributes to the effective design of combined ventilation for bidirectional excavation tunnels with an inclined shaft,ultimately improving the air quality within the tunnel. 展开更多
关键词 bidirectional excavation tunnel inclined shaft hybrid ventilation scheme computational fluid dynamics ventilation efficiency
在线阅读 下载PDF
Effect of mechanical ventilation on urine volume and expression of aquaporins in rabbits
19
作者 Yan Sun Jiamin Yang +9 位作者 Shujing Zhang Yushan Gao Yixi Jin Min Wang Lei Ni Zhenyi Wang Pengfei Kang Yan Qiu Xiaolei Liu Yuhang Li 《Journal of Traditional Chinese Medical Sciences》 2017年第3期272-279,共8页
Objective:To explore biological mechanisms underlying the traditional Chinese medicine theory of 'lung governing the regulation of water passage' by observing effects of mechanical ventilation on urine volume ... Objective:To explore biological mechanisms underlying the traditional Chinese medicine theory of 'lung governing the regulation of water passage' by observing effects of mechanical ventilation on urine volume and related bioactive substances.Methods:A total of 16 male rabbits were randomly divided into control and lung expansion model groups (n =8 per group),which were examined during the following four respiratory intervention stages (10 minutes each):(1) free breathing without any respiratory intervention;(2) lung expansion induced by mechanical ventilator;(3) free breathing without ventilator intervention;(4) cutting of bilateral sympathetic,vagus,and depressor nerves with mechanical ventilation.Data for breathing rate,blood pressure,and urine drops were recorded with a Medlab data acquisition system.Levels of nitric oxide (NO),antidiuretic hormone (ADH),endothelin 1 (ET-1),angiotensin Ⅱ (AngⅡ),prostaglandin E2 (PGE2),and atrial natriuretic peptide (ANP) were detected in lung tissue,kidney tissue,and serum by enzyme-linked immunosorbent assay.Protein expression of aquaporins 1 and 2 (AQP1 and AQP2) was detected in kidney tissue by immunohistochemistry,while Aqp1 mRNA and Aqp2 mRNA levels in kidney tissue were detected by real-time quantitative polymerase chain reaction.Histopathological changes in lung and kidney tissues were examined by hematoxylin and eosin staining.Results:Compared with the control group,number of urine drops during the second and fourth stages is significantly decreased in the model group (P <.05).In addition,NO and PGE2 content in lung and kidney tissues was significantly decreased in the model group (P <.05).ANP content in model group lung and kidney tissues was significantly increased (P <.05),while ET-1 content in these tissues was significantly decreased (P <.05).AngⅡ content in kidney tissue was significantly decreased in the model group (P <.05),while serum AngⅡ content of the animals was significantly increased (P <.05).Expression of AQP1 and AQP2 proteins in kidney tissue was significantly higher in the model group than in the control group (P <.05).No obvious histopathological changes were observed in lung or kidney tissues of animals in either group.Conclusions:Mechanical ventilation reduced urine volume,increased expression of AQP1 and AQP2 in kidney tissue,and altered levels of NO,ADH,ET-1,AngⅡ,PGE2,and ANP in lung tissue,kidney tissue,and serum.These results provide an experimental basis for preliminary studies of mechanisms under pinning the theory of 'lung governing the regulation of water passage'. 展开更多
关键词 Mechanical ventilation Lung governing the regulation of water PASSAGE URINE volume AQUAPORIN-1 AQUAPORIN-2
在线阅读 下载PDF
Experimental and numerical simulation study on forced ventilation and dust removal of coal mine heading surface
20
作者 Haotian Zheng Bingyou Jiang +1 位作者 Haoyu Wang Yuannan Zheng 《International Journal of Coal Science & Technology》 EI CAS CSCD 2024年第1期204-220,共17页
In order to study the problems of unreasonable airflow distribution and serious dust pollution in a heading surface,an experimental platform for forced ventilation and dust removal was built based on the similar princ... In order to study the problems of unreasonable airflow distribution and serious dust pollution in a heading surface,an experimental platform for forced ventilation and dust removal was built based on the similar principles.Through the similar experiment and numerical simulation,the distribution of airflow field in the roadway and the spatial and temporal evolution of dust pollution under the conditions of forced ventilation were determined.The airflow field in the roadway can be divided into three zones:jet zone,vortex zone and reflux zone.The dust concentration gradually decreases from the head to the rear of the roadway.Under the forced ventilation conditions,there is a unilateral accumulation of dust,with higher dust concentrations away from the ducts.The position of the equipment has an interception effect on the dust.The maximum error between the test value and the simulation result is 12.9%,which verifies the accuracy of the experimental results.The research results can provide theoretical guidance for the application of dust removal technology in coal mine. 展开更多
关键词 Heading surface Forced ventilation Airflow field Dust pollution
在线阅读 下载PDF
上一页 1 2 55 下一页 到第