This paper investigates the effect of the Phase Angle Error of a Constant Amplitude Voltage signal in determining the Total Vector Error (TVE) of the Phasor Measurement Unit (PMU) using MATLAB/Simulink. The phase angl...This paper investigates the effect of the Phase Angle Error of a Constant Amplitude Voltage signal in determining the Total Vector Error (TVE) of the Phasor Measurement Unit (PMU) using MATLAB/Simulink. The phase angle error is measured as a function of time in microseconds at four points on the IEEE 14-bus system. When the 1 pps Global Positioning System (GPS) signal to the PMU is lost, sampling of voltage signals on the power grid is done at different rates as it is a function of time. The relationship between the PMU measured signal phase angle and the sampling rate is established by injecting a constant amplitude signal at two different points on the grid. In the simulation, 64 cycles per second is used as the reference while 24 cycles per second is used to represent the fault condition. Results show that a change in the sampling rate from 64 bps to 24 bps in the PMUs resulted in phase angle error in the voltage signals measured by the PMU at four VI Measurement points. The phase angle error measurement that was determined as a time function was used to determine the TVE. Results show that (TVE) was more than 1% in all the cases.展开更多
Phasor Measurement Units(PMUs)provide Global Positioning System(GPS)time-stamped synchronized measurements of voltage and current with the phase angle of the system at certain points along with the grid system.Those s...Phasor Measurement Units(PMUs)provide Global Positioning System(GPS)time-stamped synchronized measurements of voltage and current with the phase angle of the system at certain points along with the grid system.Those synchronized data measurements are extracted in the form of amplitude and phase from various locations of the power grid to monitor and control the power system condition.A PMU device is a crucial part of the power equipment in terms of the cost and operative point of view.However,such ongoing development and improvement to PMUs’principal work are essential to the network operators to enhance the grid quality and the operating expenses.This paper introduces a proposed method that led to lowcost and less complex techniques to optimize the performance of PMU using Second-Order Kalman Filter.It is based on the Asyncrhophasor technique resulting in a phase error minimization when receiving the signal from an access point or from the main access point.The MATLAB model has been created to implement the proposed method in the presence of Gaussian and non-Gaussian.The results have shown the proposed method which is Second-Order Kalman Filter outperforms the existing model.The results were tested usingMean Square Error(MSE).The proposed Second-Order Kalman Filter method has been replaced with a synchronization unit into thePMUstructure to clarify the significance of the proposed new PMU.展开更多
With the advent of phasor measurement unit (PMU) technology, the grid observability has got a new dimension. This facet of technology helps in getting the real-time and dynamic scenario of the grid operations which wa...With the advent of phasor measurement unit (PMU) technology, the grid observability has got a new dimension. This facet of technology helps in getting the real-time and dynamic scenario of the grid operations which was a remote possibility some decades before. Achieving this level of observability puts us at an advantage of responding to the system faults with reduced response time, and helps in restoring the grid stability within fraction of second. This paper demonstrates the detailed fault characterization from the PMU inputs, after illustrations from various real-time examples and different faults occurred in India. This paper tries to shed some light on areas where the accurate fault characterization can help the operator in taking the right decision for reliable grid operations.展开更多
Owing to the large-scale grid connection of new energy sources, several installed power electronic devices introduce sub-/supersynchronous inter-harmonics into power signals, resulting in the frequent occurrence of su...Owing to the large-scale grid connection of new energy sources, several installed power electronic devices introduce sub-/supersynchronous inter-harmonics into power signals, resulting in the frequent occurrence of subsynchronous oscillations(SSOs). The SSOs may cause significant harm to generator sets and power systems;thus, online monitoring and accurate alarms for power systems are crucial for their safe and stable operation. Phasor measurement units(PMUs) can realize the dynamic real-time monitoring of power systems. Based on PMU phasor measurements, this study proposes a method for SSO online monitoring and alarm implementation for the main station of a PMU. First, fast Fourier transform frequency spectrum analysis is performed on PMU current phasor amplitude data to obtain subsynchronous frequency components. Second, the support vector machine learning algorithm is trained to obtain the amplitude threshold and subsequently filter out safe components and retain harmful ones. Finally, the adaptive duration threshold is determined according to frequency susceptibility, amplitude attenuation, and energy accumulation to decide whether to transmit an alarm signal. Experiments based on field data verify the effectiveness of the proposed method.展开更多
This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault curre...This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault current. In this paper, an index based on phasors change is proposed for HIF detection. The phasors are measured by PMU to obtain the square summation of errors. Two types of data are used for error calculation. The first one is sampled data and the second one is estimated data. But this index is not enough to declare presence of a HIF. Therefore another index introduces in order to distinguish the load switching from HIF. Second index utilizes 3rd harmonic current angle because this number of harmonic has a special behaviour during HIF. The verification of the proposed method is done by different simulation cases in EMTP/MATLAB.展开更多
To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient...To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation.展开更多
The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by syn...The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by synchronizing their output voltage with the one at the point of common coupling. In the circumstances, a concept of Virtual Synchronous Machine (VSM) is proposed, where the self-commutated power converters are emulating synchronous generators. This paper describes a converter control to contribute to enhancing the synchronizing torque. The proposed control is similar to the VSM but it simply realizes active power trades among power generation units including converter-based generators by modulating phase angles of their output voltages. Therefore, it can provide an effective support to regulate the system frequency where the total rated power of the converter-based generators increases as much as the one of conventional rotating generators like a microgrid. This paper especially focuses on its robustness where the number of converter-based generators is increased or they are dispersed in the power network. The effectiveness is verified by simulation study based on instantaneous values.展开更多
This paper proposes a method for optimal placement of synchronized PMUs (phasor measurement units) in electrical power systems using a MCGA (modified canonical genetic algorithm), which the goal is to determine th...This paper proposes a method for optimal placement of synchronized PMUs (phasor measurement units) in electrical power systems using a MCGA (modified canonical genetic algorithm), which the goal is to determine the minimum number of PMUs, as well as the optimal location of these units to ensure the complete topological observability of the system. In case of more than one solution, a strategy of analysis of the design matrix rank is applied to determine the solution with the lower number of critical measurements. In the proposed method of placement, modifications are made in the crossover and mutation genetic operators, as well as in the formation of the subpopulation, and are considered restrictive hypotheses in the search space to improve the performance in solving the optimization problem. Simulations are performed using the IEEE 14-bus, IEEE 30-bus and New England 39-bus test systems. The proposed method is applied on the IEEE 118-bus test system considering the presence of observable zones formed by conventional measurements.展开更多
In the world, recent increased disturbances, congestion management problems, and increases of complexity in operating power systems have brought the need for integrations and improvements of power systems. Advanced ap...In the world, recent increased disturbances, congestion management problems, and increases of complexity in operating power systems have brought the need for integrations and improvements of power systems. Advanced applications in WAMPAC (wide area monitoring, protection, and control) systems provide a cost effective solution to improve system planning, operation, maintenance, and energy trading. Synchronized measurement technology and the application are an important element of WAMPAC. In addition, PMUs (phasor measurement units) are the most accurate and advanced time-synchronized technology available for WAMPAC application. Therefore, the original measurement system of PMUs has been constructed in Japan. This paper describes the estimation method of a center of inertia frequency by applying actual measurement data. The application of this method enables us to extract power system oscillations from measurement data appropriately. Moreover, this proposed method will help to the clarification of power system dynamics and this application will make it possible to realize the monitoring of power system oscillations associated with the power system stability.展开更多
Facing constraints imposed by storage and bandwidth limitations,the vast volume of phasor meas-urement unit(PMU)data collected by the wide-area measurement system(WAMS)for power systems cannot be fully utilized.This l...Facing constraints imposed by storage and bandwidth limitations,the vast volume of phasor meas-urement unit(PMU)data collected by the wide-area measurement system(WAMS)for power systems cannot be fully utilized.This limitation significantly hinders the effective deployment of situational awareness technologies for systematic applications.In this work,an effective curvature quantified Douglas-Peucker(CQDP)-based PMU data compression method is proposed for situational awareness of power systems.First,a curvature integrated distance(CID)for measuring the local flection and fluc-tuation of PMU signals is developed.The Doug-las-Peucker(DP)algorithm integrated with a quan-tile-based parameter adaptation scheme is then proposed to extract feature points for profiling the trends within the PMU signals.This allows adaptive adjustment of the al-gorithm parameters,so as to maintain the desired com-pression ratio and reconstruction accuracy as much as possible,irrespective of the power system dynamics.Fi-nally,case studies on the Western Electricity Coordinat-ing Council(WECC)179-bus system and the actual Guangdong power system are performed to verify the effectiveness of the proposed method.The simulation results show that the proposed method achieves stably higher compression ratio and reconstruction accuracy in both steady state and in transients of the power system,and alleviates the compression performance degradation problem faced by existing compression methods.Index Terms—Curvature quantified Douglas-Peucker,data compression,phasor measurement unit,power sys-tem situational awareness.展开更多
Synchrophasors are time-synchronized electrical measurements that represent both the magnitude and phase angle of the electrical sinusoids. Synchrophasors are measured by fast time-stamped devices called phasor measur...Synchrophasors are time-synchronized electrical measurements that represent both the magnitude and phase angle of the electrical sinusoids. Synchrophasors are measured by fast time-stamped devices called phasor measurement units(PMUs) to constitute the basis of realtime monitoring and control actions in the electric grid.Due to its enhanced situational awareness capabilities,many applications of PMUs are presented in the literature in the past decades. This paper presents a comprehensive summary of synchrophasor technology, its architecture,optimal placement techniques and its applications in electric power transmission and distribution systems. These applications include wide-area situational awareness and monitoring, state estimation, fault location and protective relaying, islanding detection etc. This review also covers some of the existing challenges in its implementation and its potential applications.展开更多
The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements.Such a complex network is susceptible to faults caused due to several reasons such ...The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements.Such a complex network is susceptible to faults caused due to several reasons such as the failure of the equipment,hostile weather conditions,etc.These faults if not detected in the real-time may lead to cascading failures resulting in a blackout.These blackouts have catastrophic consequences which result in a huge loss of resources.For example,a blackout in 2004 caused an economic loss of 10 billion U.S dollars as per the report of the Electricity Consumers Resource Council.Subsequent investigation of the blackout revealed that the catastrophe could have been prevented if there was an early warning system.Similar other blackouts across the globe forced the power system engineers to devise an effective solution for real-time monitoring and control of the power system.The consequence of these efforts is the wide area measurement system(WAMS).The WAMS consists of several sensors known as the phasor measurement units(PMUs)that collect the real information pertaining to the health of the power grid.This information in the form time synchronized voltage and current phasors is communicated to the central control center or the phasor data concentrator(PDC)where the data is analyzed for detection of power system anomalies.The communication of the synchrophasor data from each PMU to the PDC constitutes the synchrophasor communication system(SPCS).Thus,the SPCS can be considered as the edifice of the WAMS and its reliable operation is essential for the effective monitoring and control of the power system.This paper presents a comprehensive review of the various synchrophasor communication technologies,communication standards and applications.It also identifies the existing knowledge gaps and the scope for future research work.展开更多
Phasor measurement units(PMU) are playing an increasingly important role in power system dynamic security monitoring and control. However, the wide-area deployments of the renewable energy sources and the high voltage...Phasor measurement units(PMU) are playing an increasingly important role in power system dynamic security monitoring and control. However, the wide-area deployments of the renewable energy sources and the high voltage direct current(HVDC) transmission bring a large number of inter-harmonics to the power grid, which may result in further power system security problems. The impacts of inter-harmonics on synchrophasor measurements are revealed. This paper derives the phasor expressions of the signal, which contains the fundamental component and the inter-harmonics. It is found that the inter-harmonics will lead to the subsynchronous oscillation of the phasor measurements. The frequency transmutation principle between the harmonic and the phasor oscillation is revealed. Then, the field PMU data recorded during a subsynchronous oscillation, which occurred in an area of China with a high concentration of wind farms and HVDC transmission lines, are studied. A geographical wiring diagram with the subsynchronous oscillation distribution depicts the severe consequences of the inter-harmonics. In addition, the correctness of the theoretical derivation and the possibility of the inter-harmonics monitoring are verified.展开更多
The paper provides a short history of the phasor measurement unit(PMU) concept. The origin of PMU is traced to the work on developing computer based distance relay using symmetrical component theory. PMUs evolved from...The paper provides a short history of the phasor measurement unit(PMU) concept. The origin of PMU is traced to the work on developing computer based distance relay using symmetrical component theory. PMUs evolved from a portion of this relay architecture. The need for synchronization using global positioning system(GPS) is discussed, and the wide area measurement system(WAMS) utilizing PMU signals is described. A number of applications of this technology are discussed, and an account of WAMS activities in many countries around the world are provided.展开更多
Due to the increasing development of renewables in power systems,the requirements for phasor measurement units(PMUs)becomes higher.A PMU calibrator is an important tool to test and calibrate PMUs to ensure their measu...Due to the increasing development of renewables in power systems,the requirements for phasor measurement units(PMUs)becomes higher.A PMU calibrator is an important tool to test and calibrate PMUs to ensure their measurement performance.This device can provide accurate reference values for error analysis of PMUs.In this paper,a phasor algorithm with low computational complexity and high accuracy is proposed for the PMU calibrator.This method reduces the processor requirements and development costs of the calibrator,thereby facilitating its popularization.At first,an enhanced discrete Fourier transform(DFT)method is put forward:1)the frequency response of the windowed DFT method is analyzed to reveal its large measurement errors under dynamic conditions;2)the parameter requirements of the DFT window that is regarded as a lowpass filter are analyzed,and thus a lowpass filter with better filtering performance is designed as the window coefficients to improve the estimation accuracy.Then,based on the enhanced DFT algorithm,a calibrator algorithm framework consisting of two-stage filters and a signal recognition module is established.This algorithm can consider the anti-interference ability and dynamic measurement accuracy at a low reporting rate.Simulation and experimental test results show that the proposed calibrator algorithm provides high-accuracy measurements of the static and dynamic signals with low computational complexity.展开更多
The characterization of sinusoidal signals with time varying amplitude and phase is useful and applicable for many fields.Therefore several algorithms have been suggested to estimate main aspects of these signals.With...The characterization of sinusoidal signals with time varying amplitude and phase is useful and applicable for many fields.Therefore several algorithms have been suggested to estimate main aspects of these signals.Within no standard approach to test the properties of these algorithms,it seems to be helpful to discuss a large class of algorithms according to their properties.In this paper,six methods of estimating dynamic phasor have been reviewed and discussed which three of them are based on least square and others are based on Kalman filter.Taylor expansion is used as a first step and continued with least square or Kalman filter in accordance with the proposal observer of each method.The theoretical processes of these methods are briefly clarified.The characterizations have been made by some tests in time and frequency domains.The tests include amplitude step,phase step,frequency step,frequency response,total vector error,transient monitor,noise,sample number,computation time,harmonic and DC offset which build a framework to compare the different methods.展开更多
The interactions between randomly fluctuating power outputs from photovoltaic(PV) at the DC side and background voltage distortions at the AC side could generate interharmonics in the PV grid-connected system(PVGS). T...The interactions between randomly fluctuating power outputs from photovoltaic(PV) at the DC side and background voltage distortions at the AC side could generate interharmonics in the PV grid-connected system(PVGS). There is no universal method that can reveal the transmission mechanism of interharmonics and realize accurate calculation in different scenarios where interharmonics exist in the PVGS. Therefore, extended dynamic phasors(EDPs) and EDP sequence components(EDPSCs) are employed in the interharmonic analysis of the PVGS. First, the dynamic phasors(DPs) and dynamic phasor sequence components(DPSCs) are extended into EDPs and EDPSCs by selecting a suitable fundamental frequency other than the power frequency. Second, an interharmonic analysis model of the PVGS is formulated as a set of state space equations. Third, with the decoupling characteristics of EDPSCs,generation principles and interactions among the interharmonics in the PVGS are presented by the sequence components,and its correctness is verified by simulation and experiment.The presented model can be used to accurately calculate the interharmonics generated in the PVGS both at the AC and DC sides. Because of the decoupling among the EDPSCs, the set of state space equations can effectively describe the principle.展开更多
Large interconnected power systems are usually subjected to natural oscillation(NO)and forced oscillation(FO).NO occurs due to system transient response and is characterized by several oscillation modes,while FO occur...Large interconnected power systems are usually subjected to natural oscillation(NO)and forced oscillation(FO).NO occurs due to system transient response and is characterized by several oscillation modes,while FO occurs due to external perturbations driving generation sources.Compared to NO,FO is considered a more severe threat to the safe and reliable operation of power systems.Therefore,it is important to locate the source of FO so corrective actions can be taken to ensure stable power system operation.In this paper,a novel approach based on two-step signal processing is proposed to characterize FO in terms of its frequency components,duration,nature,and the location of the source.Data recorded by the Phasor Measurement Units(PMUs)in a Wide Area Monitoring System(WAMS)is utilized for analysis.As PMU data usually contains white noise and appears as multi-frequency oscillatory signal,the first step is to de-noise the raw PMU data by decomposing it into a series of intrinsic mode functions(IMF)using Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise(ICEEMDAN)technique.The most appropriate IMF containing the vital information is selected using the correlation technique.The second step involves various signal processing and statistical analysis tools such as segmented Power Spectrum Density(PSD),excess kurtosis,cross PSD etc.to achieve the desired objectives.The analysis performed on the simulated two-area four-machine system,reduced WECC-179 bus 29 machine system,and the real-time power system PMU data set from ISO New England,demonstrates the accuracy of the proposed method.The proposed approach is independent of complex network topologies and their characteristics,and is also robust against measurement noise usually contained in PMU data.展开更多
文摘This paper investigates the effect of the Phase Angle Error of a Constant Amplitude Voltage signal in determining the Total Vector Error (TVE) of the Phasor Measurement Unit (PMU) using MATLAB/Simulink. The phase angle error is measured as a function of time in microseconds at four points on the IEEE 14-bus system. When the 1 pps Global Positioning System (GPS) signal to the PMU is lost, sampling of voltage signals on the power grid is done at different rates as it is a function of time. The relationship between the PMU measured signal phase angle and the sampling rate is established by injecting a constant amplitude signal at two different points on the grid. In the simulation, 64 cycles per second is used as the reference while 24 cycles per second is used to represent the fault condition. Results show that a change in the sampling rate from 64 bps to 24 bps in the PMUs resulted in phase angle error in the voltage signals measured by the PMU at four VI Measurement points. The phase angle error measurement that was determined as a time function was used to determine the TVE. Results show that (TVE) was more than 1% in all the cases.
文摘Phasor Measurement Units(PMUs)provide Global Positioning System(GPS)time-stamped synchronized measurements of voltage and current with the phase angle of the system at certain points along with the grid system.Those synchronized data measurements are extracted in the form of amplitude and phase from various locations of the power grid to monitor and control the power system condition.A PMU device is a crucial part of the power equipment in terms of the cost and operative point of view.However,such ongoing development and improvement to PMUs’principal work are essential to the network operators to enhance the grid quality and the operating expenses.This paper introduces a proposed method that led to lowcost and less complex techniques to optimize the performance of PMU using Second-Order Kalman Filter.It is based on the Asyncrhophasor technique resulting in a phase error minimization when receiving the signal from an access point or from the main access point.The MATLAB model has been created to implement the proposed method in the presence of Gaussian and non-Gaussian.The results have shown the proposed method which is Second-Order Kalman Filter outperforms the existing model.The results were tested usingMean Square Error(MSE).The proposed Second-Order Kalman Filter method has been replaced with a synchronization unit into thePMUstructure to clarify the significance of the proposed new PMU.
文摘With the advent of phasor measurement unit (PMU) technology, the grid observability has got a new dimension. This facet of technology helps in getting the real-time and dynamic scenario of the grid operations which was a remote possibility some decades before. Achieving this level of observability puts us at an advantage of responding to the system faults with reduced response time, and helps in restoring the grid stability within fraction of second. This paper demonstrates the detailed fault characterization from the PMU inputs, after illustrations from various real-time examples and different faults occurred in India. This paper tries to shed some light on areas where the accurate fault characterization can help the operator in taking the right decision for reliable grid operations.
基金supported by the National Key R&D Pro gram (2017YFB0902901)National Nature Science Founda tion of China (51725702, 51627811, 51707064)。
文摘Owing to the large-scale grid connection of new energy sources, several installed power electronic devices introduce sub-/supersynchronous inter-harmonics into power signals, resulting in the frequent occurrence of subsynchronous oscillations(SSOs). The SSOs may cause significant harm to generator sets and power systems;thus, online monitoring and accurate alarms for power systems are crucial for their safe and stable operation. Phasor measurement units(PMUs) can realize the dynamic real-time monitoring of power systems. Based on PMU phasor measurements, this study proposes a method for SSO online monitoring and alarm implementation for the main station of a PMU. First, fast Fourier transform frequency spectrum analysis is performed on PMU current phasor amplitude data to obtain subsynchronous frequency components. Second, the support vector machine learning algorithm is trained to obtain the amplitude threshold and subsequently filter out safe components and retain harmful ones. Finally, the adaptive duration threshold is determined according to frequency susceptibility, amplitude attenuation, and energy accumulation to decide whether to transmit an alarm signal. Experiments based on field data verify the effectiveness of the proposed method.
文摘This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault current. In this paper, an index based on phasors change is proposed for HIF detection. The phasors are measured by PMU to obtain the square summation of errors. Two types of data are used for error calculation. The first one is sampled data and the second one is estimated data. But this index is not enough to declare presence of a HIF. Therefore another index introduces in order to distinguish the load switching from HIF. Second index utilizes 3rd harmonic current angle because this number of harmonic has a special behaviour during HIF. The verification of the proposed method is done by different simulation cases in EMTP/MATLAB.
基金supported by the State Grid Science and Technology Project (grant no. KJ2021-069)。
文摘To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation.
文摘The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by synchronizing their output voltage with the one at the point of common coupling. In the circumstances, a concept of Virtual Synchronous Machine (VSM) is proposed, where the self-commutated power converters are emulating synchronous generators. This paper describes a converter control to contribute to enhancing the synchronizing torque. The proposed control is similar to the VSM but it simply realizes active power trades among power generation units including converter-based generators by modulating phase angles of their output voltages. Therefore, it can provide an effective support to regulate the system frequency where the total rated power of the converter-based generators increases as much as the one of conventional rotating generators like a microgrid. This paper especially focuses on its robustness where the number of converter-based generators is increased or they are dispersed in the power network. The effectiveness is verified by simulation study based on instantaneous values.
文摘This paper proposes a method for optimal placement of synchronized PMUs (phasor measurement units) in electrical power systems using a MCGA (modified canonical genetic algorithm), which the goal is to determine the minimum number of PMUs, as well as the optimal location of these units to ensure the complete topological observability of the system. In case of more than one solution, a strategy of analysis of the design matrix rank is applied to determine the solution with the lower number of critical measurements. In the proposed method of placement, modifications are made in the crossover and mutation genetic operators, as well as in the formation of the subpopulation, and are considered restrictive hypotheses in the search space to improve the performance in solving the optimization problem. Simulations are performed using the IEEE 14-bus, IEEE 30-bus and New England 39-bus test systems. The proposed method is applied on the IEEE 118-bus test system considering the presence of observable zones formed by conventional measurements.
文摘In the world, recent increased disturbances, congestion management problems, and increases of complexity in operating power systems have brought the need for integrations and improvements of power systems. Advanced applications in WAMPAC (wide area monitoring, protection, and control) systems provide a cost effective solution to improve system planning, operation, maintenance, and energy trading. Synchronized measurement technology and the application are an important element of WAMPAC. In addition, PMUs (phasor measurement units) are the most accurate and advanced time-synchronized technology available for WAMPAC application. Therefore, the original measurement system of PMUs has been constructed in Japan. This paper describes the estimation method of a center of inertia frequency by applying actual measurement data. The application of this method enables us to extract power system oscillations from measurement data appropriately. Moreover, this proposed method will help to the clarification of power system dynamics and this application will make it possible to realize the monitoring of power system oscillations associated with the power system stability.
基金supported by the National Natural Sci-ence Foundation of China(No.52077195).
文摘Facing constraints imposed by storage and bandwidth limitations,the vast volume of phasor meas-urement unit(PMU)data collected by the wide-area measurement system(WAMS)for power systems cannot be fully utilized.This limitation significantly hinders the effective deployment of situational awareness technologies for systematic applications.In this work,an effective curvature quantified Douglas-Peucker(CQDP)-based PMU data compression method is proposed for situational awareness of power systems.First,a curvature integrated distance(CID)for measuring the local flection and fluc-tuation of PMU signals is developed.The Doug-las-Peucker(DP)algorithm integrated with a quan-tile-based parameter adaptation scheme is then proposed to extract feature points for profiling the trends within the PMU signals.This allows adaptive adjustment of the al-gorithm parameters,so as to maintain the desired com-pression ratio and reconstruction accuracy as much as possible,irrespective of the power system dynamics.Fi-nally,case studies on the Western Electricity Coordinat-ing Council(WECC)179-bus system and the actual Guangdong power system are performed to verify the effectiveness of the proposed method.The simulation results show that the proposed method achieves stably higher compression ratio and reconstruction accuracy in both steady state and in transients of the power system,and alleviates the compression performance degradation problem faced by existing compression methods.Index Terms—Curvature quantified Douglas-Peucker,data compression,phasor measurement unit,power sys-tem situational awareness.
文摘Synchrophasors are time-synchronized electrical measurements that represent both the magnitude and phase angle of the electrical sinusoids. Synchrophasors are measured by fast time-stamped devices called phasor measurement units(PMUs) to constitute the basis of realtime monitoring and control actions in the electric grid.Due to its enhanced situational awareness capabilities,many applications of PMUs are presented in the literature in the past decades. This paper presents a comprehensive summary of synchrophasor technology, its architecture,optimal placement techniques and its applications in electric power transmission and distribution systems. These applications include wide-area situational awareness and monitoring, state estimation, fault location and protective relaying, islanding detection etc. This review also covers some of the existing challenges in its implementation and its potential applications.
文摘The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements.Such a complex network is susceptible to faults caused due to several reasons such as the failure of the equipment,hostile weather conditions,etc.These faults if not detected in the real-time may lead to cascading failures resulting in a blackout.These blackouts have catastrophic consequences which result in a huge loss of resources.For example,a blackout in 2004 caused an economic loss of 10 billion U.S dollars as per the report of the Electricity Consumers Resource Council.Subsequent investigation of the blackout revealed that the catastrophe could have been prevented if there was an early warning system.Similar other blackouts across the globe forced the power system engineers to devise an effective solution for real-time monitoring and control of the power system.The consequence of these efforts is the wide area measurement system(WAMS).The WAMS consists of several sensors known as the phasor measurement units(PMUs)that collect the real information pertaining to the health of the power grid.This information in the form time synchronized voltage and current phasors is communicated to the central control center or the phasor data concentrator(PDC)where the data is analyzed for detection of power system anomalies.The communication of the synchrophasor data from each PMU to the PDC constitutes the synchrophasor communication system(SPCS).Thus,the SPCS can be considered as the edifice of the WAMS and its reliable operation is essential for the effective monitoring and control of the power system.This paper presents a comprehensive review of the various synchrophasor communication technologies,communication standards and applications.It also identifies the existing knowledge gaps and the scope for future research work.
文摘Phasor measurement units(PMU) are playing an increasingly important role in power system dynamic security monitoring and control. However, the wide-area deployments of the renewable energy sources and the high voltage direct current(HVDC) transmission bring a large number of inter-harmonics to the power grid, which may result in further power system security problems. The impacts of inter-harmonics on synchrophasor measurements are revealed. This paper derives the phasor expressions of the signal, which contains the fundamental component and the inter-harmonics. It is found that the inter-harmonics will lead to the subsynchronous oscillation of the phasor measurements. The frequency transmutation principle between the harmonic and the phasor oscillation is revealed. Then, the field PMU data recorded during a subsynchronous oscillation, which occurred in an area of China with a high concentration of wind farms and HVDC transmission lines, are studied. A geographical wiring diagram with the subsynchronous oscillation distribution depicts the severe consequences of the inter-harmonics. In addition, the correctness of the theoretical derivation and the possibility of the inter-harmonics monitoring are verified.
文摘The paper provides a short history of the phasor measurement unit(PMU) concept. The origin of PMU is traced to the work on developing computer based distance relay using symmetrical component theory. PMUs evolved from a portion of this relay architecture. The need for synchronization using global positioning system(GPS) is discussed, and the wide area measurement system(WAMS) utilizing PMU signals is described. A number of applications of this technology are discussed, and an account of WAMS activities in many countries around the world are provided.
基金supported in part by the National Natural Science Foundation of China(51627811,51725702).
文摘Due to the increasing development of renewables in power systems,the requirements for phasor measurement units(PMUs)becomes higher.A PMU calibrator is an important tool to test and calibrate PMUs to ensure their measurement performance.This device can provide accurate reference values for error analysis of PMUs.In this paper,a phasor algorithm with low computational complexity and high accuracy is proposed for the PMU calibrator.This method reduces the processor requirements and development costs of the calibrator,thereby facilitating its popularization.At first,an enhanced discrete Fourier transform(DFT)method is put forward:1)the frequency response of the windowed DFT method is analyzed to reveal its large measurement errors under dynamic conditions;2)the parameter requirements of the DFT window that is regarded as a lowpass filter are analyzed,and thus a lowpass filter with better filtering performance is designed as the window coefficients to improve the estimation accuracy.Then,based on the enhanced DFT algorithm,a calibrator algorithm framework consisting of two-stage filters and a signal recognition module is established.This algorithm can consider the anti-interference ability and dynamic measurement accuracy at a low reporting rate.Simulation and experimental test results show that the proposed calibrator algorithm provides high-accuracy measurements of the static and dynamic signals with low computational complexity.
文摘The characterization of sinusoidal signals with time varying amplitude and phase is useful and applicable for many fields.Therefore several algorithms have been suggested to estimate main aspects of these signals.Within no standard approach to test the properties of these algorithms,it seems to be helpful to discuss a large class of algorithms according to their properties.In this paper,six methods of estimating dynamic phasor have been reviewed and discussed which three of them are based on least square and others are based on Kalman filter.Taylor expansion is used as a first step and continued with least square or Kalman filter in accordance with the proposal observer of each method.The theoretical processes of these methods are briefly clarified.The characterizations have been made by some tests in time and frequency domains.The tests include amplitude step,phase step,frequency step,frequency response,total vector error,transient monitor,noise,sample number,computation time,harmonic and DC offset which build a framework to compare the different methods.
基金supported by China Southern Power Grid Co.,Ltd.(No.090000KK52180116)。
文摘The interactions between randomly fluctuating power outputs from photovoltaic(PV) at the DC side and background voltage distortions at the AC side could generate interharmonics in the PV grid-connected system(PVGS). There is no universal method that can reveal the transmission mechanism of interharmonics and realize accurate calculation in different scenarios where interharmonics exist in the PVGS. Therefore, extended dynamic phasors(EDPs) and EDP sequence components(EDPSCs) are employed in the interharmonic analysis of the PVGS. First, the dynamic phasors(DPs) and dynamic phasor sequence components(DPSCs) are extended into EDPs and EDPSCs by selecting a suitable fundamental frequency other than the power frequency. Second, an interharmonic analysis model of the PVGS is formulated as a set of state space equations. Third, with the decoupling characteristics of EDPSCs,generation principles and interactions among the interharmonics in the PVGS are presented by the sequence components,and its correctness is verified by simulation and experiment.The presented model can be used to accurately calculate the interharmonics generated in the PVGS both at the AC and DC sides. Because of the decoupling among the EDPSCs, the set of state space equations can effectively describe the principle.
文摘Large interconnected power systems are usually subjected to natural oscillation(NO)and forced oscillation(FO).NO occurs due to system transient response and is characterized by several oscillation modes,while FO occurs due to external perturbations driving generation sources.Compared to NO,FO is considered a more severe threat to the safe and reliable operation of power systems.Therefore,it is important to locate the source of FO so corrective actions can be taken to ensure stable power system operation.In this paper,a novel approach based on two-step signal processing is proposed to characterize FO in terms of its frequency components,duration,nature,and the location of the source.Data recorded by the Phasor Measurement Units(PMUs)in a Wide Area Monitoring System(WAMS)is utilized for analysis.As PMU data usually contains white noise and appears as multi-frequency oscillatory signal,the first step is to de-noise the raw PMU data by decomposing it into a series of intrinsic mode functions(IMF)using Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise(ICEEMDAN)technique.The most appropriate IMF containing the vital information is selected using the correlation technique.The second step involves various signal processing and statistical analysis tools such as segmented Power Spectrum Density(PSD),excess kurtosis,cross PSD etc.to achieve the desired objectives.The analysis performed on the simulated two-area four-machine system,reduced WECC-179 bus 29 machine system,and the real-time power system PMU data set from ISO New England,demonstrates the accuracy of the proposed method.The proposed approach is independent of complex network topologies and their characteristics,and is also robust against measurement noise usually contained in PMU data.