The objective of this work is to develop a novel methodology for determining real resistivity of conductive asphalt concrete based on two-electrode method.Due to an influence of contact resistance,the measured resisti...The objective of this work is to develop a novel methodology for determining real resistivity of conductive asphalt concrete based on two-electrode method.Due to an influence of contact resistance,the measured resistivity is always not equal to the real resistivity.To determine the real resistivity,a linear relationship of the measured resistivity,contact resistance and the real resistivity was established.Then experiments for six specimens with varying graphite contents were designed and performed to validate the formulation.Results of experiments demonstrate that the slope of the line represents contact resistance,and the intercept indicates the real resistivity.The effects of graphite content on contact resistance and real resistivity are also revealed.Finally,results show that the influence of contact resistance on accuracy of resisitvity measurement becomes more serious if graphite content is beyond 3%.Hence,it is the time to choose this novel methodology to determine the real resistivity of asphalt concrete by taking account of contact resistance.展开更多
We present systematic investigations on the physics,detection performance and inversion of logging-while-drilling extradeep azimuthal resistivity measurements(EDARM).First,the definitions of EDRAM measurements are dis...We present systematic investigations on the physics,detection performance and inversion of logging-while-drilling extradeep azimuthal resistivity measurements(EDARM).First,the definitions of EDRAM measurements are discussed,followed by the derivation of the attenuation and phase-shift geometrical factors to illustrate the relative contributions of formation units to the observed signals.Then,a new definition of detection depth,which considers the uncertainty of inversion results caused by the data noise,is proposed to quantify the detection capability of ED ARM.Finally,the B ayesian theory associated with Markov chain Monte Carlo sampling is introduced for fast processing of EDARM data.Numerical results show that ED ARM is capable of detecting the azimuth and distance of remote bed boundaries,and the detection capability increases with increasing spacing and resistivity contrast.The EDARM tool can accommodate a large range of formation resistivity and is able to provide the resistivity anisotropy at arbitrary relative dipping angles.In addition,multiple bed boundaries and reservoir images near the borehole are readily obtained by using the Bayesian inversion.展开更多
It is difficult to predict earthquakes by earthresistivity measurement with single-poleseparation. Taking a shallow seated horizontally stratification model, we developed a new measurement system with multipoleseparat...It is difficult to predict earthquakes by earthresistivity measurement with single-poleseparation. Taking a shallow seated horizontally stratification model, we developed a new measurement system with multipoleseparations and its corresponding inversion technique of the earth-resistivity to improve the prediction efficiency. Long-term experiments and investigations at several stations show that the new method based on resisti-vity variations at the bottom of shollow seated stratified medium is obviously superior to that directly based on the earth-resistivity itself.展开更多
We present a probe factor for a simple measurement device, which can be used to determine in-situ electrical resistivity in soils or other penetrable bodies. The probe is primarily sensitive to the material immediatel...We present a probe factor for a simple measurement device, which can be used to determine in-situ electrical resistivity in soils or other penetrable bodies. The probe is primarily sensitive to the material immediately surrounding it and therefore is ideal for determining localized conductivities. The geometry of the probe can be scaled to effectively adjust the region of interest. The calibration, or “probe factor” is a function of the geometry, as well as the electrode configuration. Results are presented assuming a Wenner array configuration, however they can easily be extended to other geometries, such as the Schlumberger or dipole-dipole array.展开更多
Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursi...Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursive procedure and calculating the optimum number ofcontrol points. The reconstruction precision is evaluated through Ja-cobi's transformation method.The feasibility of the measurement system and effectiveness of the reconstruction algorithm aboveare proved by experiment.展开更多
The status and the variation of electrical resistance of impacted carbon fiber/epoxy-matrix composites were studied by ultrasonic F-scan and electrical resistance measurement The experimental results shows that impact...The status and the variation of electrical resistance of impacted carbon fiber/epoxy-matrix composites were studied by ultrasonic F-scan and electrical resistance measurement The experimental results shows that impact damage energy threshold value of carbon fabric/epoxy-matrix composites can determine by using ultrasonic F-scan. When the impact energy exceeds the threshold value, damage is generated in composites. Electrical resistance of impacted composites is changed owing to the contact of each carbon fiber unit in composites, which cause a change of the series-parallel in conductors. The veracity of detecting impact damage in composites can be improved in this case.展开更多
A boxcar integrator is described which is suitable for the low-repetition-rate signal processing. This boxcar integrator, named fixed-interval mode boxcar integrator, is able to reject harmonics other than the first h...A boxcar integrator is described which is suitable for the low-repetition-rate signal processing. This boxcar integrator, named fixed-interval mode boxcar integrator, is able to reject harmonics other than the first harmonic component. It can also decrease the effective time constant In many situations, the antialiasing filter with narrow bandwidth will cause distortion of the input signal. The fixed-interval mode boxcar integrator with suitable gate width can achieve relative high performance without signal distortion because the bandwidth of its antialiasing filter can be wider than that in the fixed-Point boxcar integrator. ms boxcar integrator is used as majn part of signalprocessing circult in the low resisance measurement of inductive load coil. The results of experiments show that the fixed-interval boxcar integrator is suitable for low-repetition-rate use.展开更多
After having measured the electric resistance of carbon firbre reinforced concrete (CFRC) by applying a D. C. current, it was found that the current passing through the specimen under a constant voltage decreased with...After having measured the electric resistance of carbon firbre reinforced concrete (CFRC) by applying a D. C. current, it was found that the current passing through the specimen under a constant voltage decreased with the time, and if changing the value of voltage, the electric resistance was obviously affected. When current flew through the specimen, polarisation emerged under a high votage (>5 upsilon), but that could be neglected under a low voltage (<5 upsilon).(1)展开更多
To obtain thermal contact resistance(TCR) between the vertical double-diffused metal-oxide-semiconductor(VDMOS) and the heat sink, we derived the relationship between the total thermal resistance and the contact f...To obtain thermal contact resistance(TCR) between the vertical double-diffused metal-oxide-semiconductor(VDMOS) and the heat sink, we derived the relationship between the total thermal resistance and the contact force imposed on the VDMOS. The total thermal resistance from the chip to the heat sink is measured under different contact forces, and the TCR can be extracted nondestructively from the derived relationship. Finally, the experimental results are compared with the simulation results.展开更多
Non-contact measurements of machining temperatures were performed with optical pyrometer when drilling particle(B4C) reinforced metal matrix composites(MMCs) with different drills. The effect of particle content, ...Non-contact measurements of machining temperatures were performed with optical pyrometer when drilling particle(B4C) reinforced metal matrix composites(MMCs) with different drills. The effect of particle content, cutting speed, feed rate and tool material on the maximum drilling temperature was investigated. The drilling parameters were optimized based on multiple performance characteristics in terms of the maximum cutting temperature and tool wear. According to the results, the most influential control factors on the cutting temperatures are found to be particle fraction, feed rate and interaction between the cutting speed and particle content, respectively. The influences of the cutting speed and drill material on the drilling temperature are found to be relatively lower for the used range of parameters. Minimum cutting temperatures are obtained with lower particle fraction and cutting speed, with relatively higher feed rates and carbide tools. The results reveal that optimal combination of the drilling parameters can be used to obtain both minimum cutting temperature and tool wear.展开更多
Impact damage tolerance is provided in intensity design on composites. The compression intensity of impacted composites requires more than 60% of its original intensity. The influence of impact on compressive intensit...Impact damage tolerance is provided in intensity design on composites. The compression intensity of impacted composites requires more than 60% of its original intensity. The influence of impact on compressive intensity and electrical resistance of carbon fabric/epoxy-matrix composites was studied in this paper. The experimental results shows that impact can cause damage in composites, degenerate compressive intensity, and increase resistance. The electrical resistance change rate was used as an evaluation indicator of impact damage tolerance of composites. Impact damage, which results from the applying process of composites, can be identified in time by electrical resistance measurement. So, the safety performance of composites can also be improved.展开更多
On the basis of welding transformer circuit model, a new measuring method was proposed. This method measures the peak angle of the welding current, and then calculates the dynamic power factor in each half-wave. An ar...On the basis of welding transformer circuit model, a new measuring method was proposed. This method measures the peak angle of the welding current, and then calculates the dynamic power factor in each half-wave. An artificial neural network is trained and used to generate simulation data for the analytical solution, i.e. a high-order binary polynomial, which can be easily adopted to calculate the power factor online. The tailored sensing and computing system ensures that the method possesses a real-time computational capacity and satisfying accuracy. A DSP-based resistance spot welding monitoring system was developed to perform ANN computation. The experimental results suggest that this measuring method is feasible.展开更多
A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratori...A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratories without cryogenic current comparators(CCC)or direct current comparators(DCC)bridges.Behavior of this bridge is evaluated by comparing its measured values with the unknown resistor values obtained by another method.The accuracy of the introduced bridge is in the level of 10-5 for the 1 mΩresistor,and in the level of 10-4 for the 10 mΩ,100 mΩand 1Ωresistors.Moreover,a dual voltage sources system for the measurement of DC standard resistors from 1 kΩto 100 MΩis also presented.In this system,a modification is made on the modified Wheatstone bridge to evaluate its performance by adding another digital multimeter to measure the ratio between the unknown and the standard resistors simultaneously.This bridge is verified by comparing the measured values of 10 kΩresistor obtained by the two methods with its actual value.The bridge accuracy is in the level of 10-6 except for the 1 kΩresistor,and the bridge asymmetry is also evaluated.It is found the asymmetry is in the level of 10-6 for the resistors from 10 kΩto 100 MΩand in the level of 10-5 for 1 kΩresistors.The introduced bridges operations are controlled by LabVIEW programs designed specially for this purpose,and the expanded uncertainty is also evaluated for all measurement results.展开更多
In order to explore the mineral resources buried in sea mud,it is necessary to use seabed resistivity measuring equipment,which works closer to the sediments than ordinary ship-based geophysical measuring equipment. B...In order to explore the mineral resources buried in sea mud,it is necessary to use seabed resistivity measuring equipment,which works closer to the sediments than ordinary ship-based geophysical measuring equipment. Because of the harsh environment of seafloor,high pressure and highly conductive seawater,marine magnetotelluric method developed slowly. The sea floor environment is similar to the environment of logging, According to the design of dual lateral logging equipment,a new equipment for seafloor electrical resistivity measurement is designed. Four 3D FEM models that contain resistivity abnormal targets are built to test the ability of this equipment to locate different shape of shallow buried resistivity abnormal targets in sea mud. The authors propose the method to correct the response curve while the bottom surface of this equipment is suspended or not parallel to the seafloor. The resistivity of targets can be calculated accurately.展开更多
The slug rivet is widely used in wing assembly due to its longer fatigue life and better sealing performance compared with other connection technologies.As a countersink with dual-angle is widely adopted for this type...The slug rivet is widely used in wing assembly due to its longer fatigue life and better sealing performance compared with other connection technologies.As a countersink with dual-angle is widely adopted for this type of connection,the countersink diameter and depth are key factors that affect assembly quality.Therefore,it is of great importance to efficiently inspect the countersink quality to ensure high accuracy.However,contact measurements are susceptible to the loss of accuracy due to cutting debris and lube build-up,while the hole-scanning method using laser profilometry is time consuming and complex.In this paper,a non-contact method for countersink diameter and depth measurement based on a machine vision system is proposed.The countersink diameter can be directly measured by the machine vision system,while the countersink depth is determined through the countersink diameter indirectly.First,by means of image processing technology together with an improved edge detection algorithm,the countersink diameter can be obtained.Then,a 3D microscope is employed to measure the countersink depth,which helps to model the countersink.As a result,once the countersink diameter is measured,so is the depth.The experimentation demonstrated that this method has strong feasibility and enables time saving,which is conducive to improve the riveting efficiency.展开更多
The ion implantation uniformity is of vital importance for an ion implanter.In this paper,we report the,uniformity measurement for a large current ion implanter(LC-16 type) by implanting of 190-keV Ar ions into Si to ...The ion implantation uniformity is of vital importance for an ion implanter.In this paper,we report the,uniformity measurement for a large current ion implanter(LC-16 type) by implanting of 190-keV Ar ions into Si to 3×1016 atoms/cm2,followed by Rutherford backscattering spectroscopy(RBS) and sheet resistance measurement providing quantitative information on spatial distribution of dopants.The implant doses obtained from RBS at selected points of the sample give a spatial uniformity of <5%,which are confirmed by the sheet resistance measurement.While sheet resistance is an indirect method for dose evaluation of ion-implanted samples,RBS provides a competent technique for calibration of the ion implantation system.And both measurements show that good uniformity can be achieved for the ion implanter by tuning of the scanning process.展开更多
By using dropped stress creep method a new testing technique for measurement of the fa-tigue-creep interaction resistance is developed. At varied adjusted mean stresses the creep testingwas performed repeatedly When a...By using dropped stress creep method a new testing technique for measurement of the fa-tigue-creep interaction resistance is developed. At varied adjusted mean stresses the creep testingwas performed repeatedly When an unlimited extensive incubation period with zero creep rate oc-curred. the stress cavsing zero creep rate is defined as fatigue-creep resistance. The developped test-ing technique was used to measure the fatigue-creep resistance in F anc C regions. The dynamic ef-fective stress could yield a better descrption of fatigue and creep interaction. The fatigue-creep rateequations with varied exponents inF of C region are established. The different deformation mecha-nisms in F or C regions are indicated展开更多
To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is wel...To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research.展开更多
基金Project(51178348)supported by the National Natural Science Foundation of China
文摘The objective of this work is to develop a novel methodology for determining real resistivity of conductive asphalt concrete based on two-electrode method.Due to an influence of contact resistance,the measured resistivity is always not equal to the real resistivity.To determine the real resistivity,a linear relationship of the measured resistivity,contact resistance and the real resistivity was established.Then experiments for six specimens with varying graphite contents were designed and performed to validate the formulation.Results of experiments demonstrate that the slope of the line represents contact resistance,and the intercept indicates the real resistivity.The effects of graphite content on contact resistance and real resistivity are also revealed.Finally,results show that the influence of contact resistance on accuracy of resisitvity measurement becomes more serious if graphite content is beyond 3%.Hence,it is the time to choose this novel methodology to determine the real resistivity of asphalt concrete by taking account of contact resistance.
基金co-funded by Chinese Postdoctoral Science Foundation(2018M640663)the National Natural Science Foundation of China(41474100,41574118,41674131)National Science and Technology Major Project of the Ministry of Science and Technology of China(2017ZX05009-001)
文摘We present systematic investigations on the physics,detection performance and inversion of logging-while-drilling extradeep azimuthal resistivity measurements(EDARM).First,the definitions of EDRAM measurements are discussed,followed by the derivation of the attenuation and phase-shift geometrical factors to illustrate the relative contributions of formation units to the observed signals.Then,a new definition of detection depth,which considers the uncertainty of inversion results caused by the data noise,is proposed to quantify the detection capability of ED ARM.Finally,the B ayesian theory associated with Markov chain Monte Carlo sampling is introduced for fast processing of EDARM data.Numerical results show that ED ARM is capable of detecting the azimuth and distance of remote bed boundaries,and the detection capability increases with increasing spacing and resistivity contrast.The EDARM tool can accommodate a large range of formation resistivity and is able to provide the resistivity anisotropy at arbitrary relative dipping angles.In addition,multiple bed boundaries and reservoir images near the borehole are readily obtained by using the Bayesian inversion.
文摘It is difficult to predict earthquakes by earthresistivity measurement with single-poleseparation. Taking a shallow seated horizontally stratification model, we developed a new measurement system with multipoleseparations and its corresponding inversion technique of the earth-resistivity to improve the prediction efficiency. Long-term experiments and investigations at several stations show that the new method based on resisti-vity variations at the bottom of shollow seated stratified medium is obviously superior to that directly based on the earth-resistivity itself.
文摘We present a probe factor for a simple measurement device, which can be used to determine in-situ electrical resistivity in soils or other penetrable bodies. The probe is primarily sensitive to the material immediately surrounding it and therefore is ideal for determining localized conductivities. The geometry of the probe can be scaled to effectively adjust the region of interest. The calibration, or “probe factor” is a function of the geometry, as well as the electrode configuration. Results are presented assuming a Wenner array configuration, however they can easily be extended to other geometries, such as the Schlumberger or dipole-dipole array.
基金This project is supported by Provincial Natural Science Foundation of Zhejiang of China (No.599026).
文摘Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursive procedure and calculating the optimum number ofcontrol points. The reconstruction precision is evaluated through Ja-cobi's transformation method.The feasibility of the measurement system and effectiveness of the reconstruction algorithm aboveare proved by experiment.
基金Funded by the Key Laboratory of Nondestructive Testing (Nanchang Hangkong University), Ministry of Education, China(No.ZD200829001)
文摘The status and the variation of electrical resistance of impacted carbon fiber/epoxy-matrix composites were studied by ultrasonic F-scan and electrical resistance measurement The experimental results shows that impact damage energy threshold value of carbon fabric/epoxy-matrix composites can determine by using ultrasonic F-scan. When the impact energy exceeds the threshold value, damage is generated in composites. Electrical resistance of impacted composites is changed owing to the contact of each carbon fiber unit in composites, which cause a change of the series-parallel in conductors. The veracity of detecting impact damage in composites can be improved in this case.
文摘A boxcar integrator is described which is suitable for the low-repetition-rate signal processing. This boxcar integrator, named fixed-interval mode boxcar integrator, is able to reject harmonics other than the first harmonic component. It can also decrease the effective time constant In many situations, the antialiasing filter with narrow bandwidth will cause distortion of the input signal. The fixed-interval mode boxcar integrator with suitable gate width can achieve relative high performance without signal distortion because the bandwidth of its antialiasing filter can be wider than that in the fixed-Point boxcar integrator. ms boxcar integrator is used as majn part of signalprocessing circult in the low resisance measurement of inductive load coil. The results of experiments show that the fixed-interval boxcar integrator is suitable for low-repetition-rate use.
基金Financed by National Natural Science Fundation of China Key project.No.59432061
文摘After having measured the electric resistance of carbon firbre reinforced concrete (CFRC) by applying a D. C. current, it was found that the current passing through the specimen under a constant voltage decreased with the time, and if changing the value of voltage, the electric resistance was obviously affected. When current flew through the specimen, polarisation emerged under a high votage (>5 upsilon), but that could be neglected under a low voltage (<5 upsilon).(1)
基金Project supported by the National Natural Science Foundation of China(Grant No.61204081)
文摘To obtain thermal contact resistance(TCR) between the vertical double-diffused metal-oxide-semiconductor(VDMOS) and the heat sink, we derived the relationship between the total thermal resistance and the contact force imposed on the VDMOS. The total thermal resistance from the chip to the heat sink is measured under different contact forces, and the TCR can be extracted nondestructively from the derived relationship. Finally, the experimental results are compared with the simulation results.
文摘Non-contact measurements of machining temperatures were performed with optical pyrometer when drilling particle(B4C) reinforced metal matrix composites(MMCs) with different drills. The effect of particle content, cutting speed, feed rate and tool material on the maximum drilling temperature was investigated. The drilling parameters were optimized based on multiple performance characteristics in terms of the maximum cutting temperature and tool wear. According to the results, the most influential control factors on the cutting temperatures are found to be particle fraction, feed rate and interaction between the cutting speed and particle content, respectively. The influences of the cutting speed and drill material on the drilling temperature are found to be relatively lower for the used range of parameters. Minimum cutting temperatures are obtained with lower particle fraction and cutting speed, with relatively higher feed rates and carbide tools. The results reveal that optimal combination of the drilling parameters can be used to obtain both minimum cutting temperature and tool wear.
基金Funded by Key Laboratory of Nondestructive Testing (Nanchang Hangkong University)Ministry of Education, China(No. ZD200829001)Department of Education of Jiangxi Province, China(No. GJJ10531)
文摘Impact damage tolerance is provided in intensity design on composites. The compression intensity of impacted composites requires more than 60% of its original intensity. The influence of impact on compressive intensity and electrical resistance of carbon fabric/epoxy-matrix composites was studied in this paper. The experimental results shows that impact can cause damage in composites, degenerate compressive intensity, and increase resistance. The electrical resistance change rate was used as an evaluation indicator of impact damage tolerance of composites. Impact damage, which results from the applying process of composites, can be identified in time by electrical resistance measurement. So, the safety performance of composites can also be improved.
基金The National Natural Science Foundation of China (No 50575145)
文摘On the basis of welding transformer circuit model, a new measuring method was proposed. This method measures the peak angle of the welding current, and then calculates the dynamic power factor in each half-wave. An artificial neural network is trained and used to generate simulation data for the analytical solution, i.e. a high-order binary polynomial, which can be easily adopted to calculate the power factor online. The tailored sensing and computing system ensures that the method possesses a real-time computational capacity and satisfying accuracy. A DSP-based resistance spot welding monitoring system was developed to perform ANN computation. The experimental results suggest that this measuring method is feasible.
文摘A new system for measuring low-ohmic standard resistors through a dual current sources bridge is introduced.It is used for low resistance measurements from 1 mΩto 1Ωat 1∶1 ratio,which is suitable for the laboratories without cryogenic current comparators(CCC)or direct current comparators(DCC)bridges.Behavior of this bridge is evaluated by comparing its measured values with the unknown resistor values obtained by another method.The accuracy of the introduced bridge is in the level of 10-5 for the 1 mΩresistor,and in the level of 10-4 for the 10 mΩ,100 mΩand 1Ωresistors.Moreover,a dual voltage sources system for the measurement of DC standard resistors from 1 kΩto 100 MΩis also presented.In this system,a modification is made on the modified Wheatstone bridge to evaluate its performance by adding another digital multimeter to measure the ratio between the unknown and the standard resistors simultaneously.This bridge is verified by comparing the measured values of 10 kΩresistor obtained by the two methods with its actual value.The bridge accuracy is in the level of 10-6 except for the 1 kΩresistor,and the bridge asymmetry is also evaluated.It is found the asymmetry is in the level of 10-6 for the resistors from 10 kΩto 100 MΩand in the level of 10-5 for 1 kΩresistors.The introduced bridges operations are controlled by LabVIEW programs designed specially for this purpose,and the expanded uncertainty is also evaluated for all measurement results.
文摘In order to explore the mineral resources buried in sea mud,it is necessary to use seabed resistivity measuring equipment,which works closer to the sediments than ordinary ship-based geophysical measuring equipment. Because of the harsh environment of seafloor,high pressure and highly conductive seawater,marine magnetotelluric method developed slowly. The sea floor environment is similar to the environment of logging, According to the design of dual lateral logging equipment,a new equipment for seafloor electrical resistivity measurement is designed. Four 3D FEM models that contain resistivity abnormal targets are built to test the ability of this equipment to locate different shape of shallow buried resistivity abnormal targets in sea mud. The authors propose the method to correct the response curve while the bottom surface of this equipment is suspended or not parallel to the seafloor. The resistivity of targets can be calculated accurately.
文摘The slug rivet is widely used in wing assembly due to its longer fatigue life and better sealing performance compared with other connection technologies.As a countersink with dual-angle is widely adopted for this type of connection,the countersink diameter and depth are key factors that affect assembly quality.Therefore,it is of great importance to efficiently inspect the countersink quality to ensure high accuracy.However,contact measurements are susceptible to the loss of accuracy due to cutting debris and lube build-up,while the hole-scanning method using laser profilometry is time consuming and complex.In this paper,a non-contact method for countersink diameter and depth measurement based on a machine vision system is proposed.The countersink diameter can be directly measured by the machine vision system,while the countersink depth is determined through the countersink diameter indirectly.First,by means of image processing technology together with an improved edge detection algorithm,the countersink diameter can be obtained.Then,a 3D microscope is employed to measure the countersink depth,which helps to model the countersink.As a result,once the countersink diameter is measured,so is the depth.The experimentation demonstrated that this method has strong feasibility and enables time saving,which is conducive to improve the riveting efficiency.
基金supported by the National Natural Science Foundation of China(Nos.11405117 and 11205116)International Cooperation Program of the Ministry of Science and Technology of China(No.2015DFR00720)
文摘The ion implantation uniformity is of vital importance for an ion implanter.In this paper,we report the,uniformity measurement for a large current ion implanter(LC-16 type) by implanting of 190-keV Ar ions into Si to 3×1016 atoms/cm2,followed by Rutherford backscattering spectroscopy(RBS) and sheet resistance measurement providing quantitative information on spatial distribution of dopants.The implant doses obtained from RBS at selected points of the sample give a spatial uniformity of <5%,which are confirmed by the sheet resistance measurement.While sheet resistance is an indirect method for dose evaluation of ion-implanted samples,RBS provides a competent technique for calibration of the ion implantation system.And both measurements show that good uniformity can be achieved for the ion implanter by tuning of the scanning process.
文摘By using dropped stress creep method a new testing technique for measurement of the fa-tigue-creep interaction resistance is developed. At varied adjusted mean stresses the creep testingwas performed repeatedly When an unlimited extensive incubation period with zero creep rate oc-curred. the stress cavsing zero creep rate is defined as fatigue-creep resistance. The developped test-ing technique was used to measure the fatigue-creep resistance in F anc C regions. The dynamic ef-fective stress could yield a better descrption of fatigue and creep interaction. The fatigue-creep rateequations with varied exponents inF of C region are established. The different deformation mecha-nisms in F or C regions are indicated
基金The National Natural Science Foundation of China(No.50878125)
文摘To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research.